| Plan Review Stops For Permit 23011125 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-26 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-26 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2023-05-26 09:35:39 | RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23011125 | | | 214 LINDA LN | | | | | | 1- REVISE ENGINEER CALCULATIONS SUBMITTED: | | | A) THE NAIL FASTENING SPACING SPECIFIED BY THE ENGINEER | | | DOESN'T MATCH THE NAIL FASTENING SPACING LISTED IN THE | | | NOA 18-0919.12 ON PAGE 55 OF 67 FOR A MAXIMUM DESIGN | | | PRESSURES OF -52.5PSF. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. CALCULATIONS WERE NOT REVISED. | | | | | | B)THE ROOF ZONES DESIGN PRESSURES SPECIFIED BY THE | | | ENGINEER ARE TOO LOW. IT LOOKS LIKE ENGINEER IS USING | | | ASCE-7-10 INSTEAD OF CURRENT ASCE-7-16. REVISE AS | | | REQUIRED. SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. CALCULATIONS WERE NOT REVISED. | | | | | | C)ENGINEER TO SPECIFY THE DESIGN PRESSURES FOR ALL 4 | | | NEW ROOF ZONES. | | | SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. CALCULATIONS WERE NOT REVISED. | | | | | | D)ENGINEER TO REVISE THE PERIMETER WIDTH DIMENSION AND | | | THE CORNER ZONES DIMENSIONS. SEE ASCE 7-16 AND REVISE | | | AS REQUIRED. | | | SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. CALCULATIONS WERE NOT REVISED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-15 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-15 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2023-05-15 11:09:26 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23011125 | | | 214 LINDA LN | | | | | | 1- REVISE ENGINEER CALCULATIONS SUBMITTED: | | | A) THE NAIL FASTENING SPACING SPECIFIED BY THE ENGINEER | | | DOESN'T MATCH THE NAIL FASTENING SPACING LISTED IN THE | | | NOA 18-0919.12 ON PAGE 55 OF 67 FOR A MAXIMUM DESIGN | | | PRESSURES OF -52.5PSF. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | B)THE ROOF ZONES DESIGN PRESSURES SPECIFIED BY THE | | | ENGINEER ARE TOO LOW. IT LOOKS LIKE ENGINEER IS USING | | | ASCE-7-10 INSTEAD OF CURRENT ASCE-7-16. REVISE AS | | | REQUIRED. SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | C)ENGINEER TO SPECIFY THE DESIGN PRESSURES FOR ALL 4 | | | NEW ROOF ZONES. | | | SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | D)ENGINEER TO REVISE THE PERIMETER WIDTH DIMENSION AND | | | THE CORNER ZONES DIMENSIONS. SEE ASCE 7-16 AND REVISE | | | AS REQUIRED. | | | SEC. R301.2.1.1 FBC-RESIDENTIAL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-04 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2023-04-04 11:39:58 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. PROVIDE THE FOLLOWING INFORMATION FOR MIAMI-DADE NOA | | | NO.: 18-0919.12 FOR THE PROPOSED FLAT ROOF SYSTEM TO BE | | | USED CORRESPONDING TO ENGINEERS CALCULATIONS. PAGES #1 | | | & #2, INSTALLATION INSTRUCTIONS FOR SYSTEM E (3) | | | PAGE(S) #55 & #56 AND LIMITATIONS PAGE(S) #67. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | 2. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER; TO CORRECT EXPOSURE | | | CATEGORY, DESIGN PRESSURES & NAILING PATTERNS. THE | | | EXPOSURE CATEGORY FOR 214 LINDA LN WEST PALM BEACH, FL | | | 33405 IS EXPOSURE CATEGORY D. | | | 3. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S), MEAN | | | ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW POSITIVE | | | DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-26 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-26 |
Time |
09:11 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-15 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-09 |
Time |
09:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-26 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-26 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2023-05-26 09:37:31 | CALCULATIONS HAVE ENGINEER'S EMBOSSED SEAL AND WET | | | SIGNATURE DATED 5-15-23. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-09 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-09 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2023-05-09 10:54:11 | CALCULATIONS HAVE ENGINEER'S EMBOSSED SEAL AND WET | | | SIGNATURE DATED 4/4/23. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-04 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2023-04-04 11:34:36 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|