| Plan Review Stops For Permit 23010885 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-01 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-01 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2023-02-01 14:26:13 | APPLICANT CONFIRMED THAT THE WORK IS ON 2737 S FLAGLER | | | DR & 130 ALMERIA RD |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-01-31 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-01-31 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2023-01-31 08:18:41 | THE PLANS APPEAR TO ENCOMPASS TWO BUILDINSG AND TWO | | | ADDRESSES, THE PRIMARY BUILDING HAVING THE ADDRESS OF | | | 2737 S FLAGLER DR AND THE SECONDARY WEST 130 ALMERIA | | | RD, PLEASE CONFIRM THAT THESE ARE CORRECT, PLEASE | | | RESPOND TO [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-20 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-20 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-21 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-17 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2023-02-21 11:44:19 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING S-3 - "STRUCTURAL NOTES" SHOW FBC 2017 USING | | | ASCE 7-10 FOR THE WIND DESIGN - SHOULD BE FBC 2020 | | | USING ASCE 7-16 FOR THE WIND DESIGN. FBC CHAPTER 35 | | | | | | 2) PLEASE PROVIDE A SURVEY SHOWING FEMA BASE FLOOD | | | ELEVATION AND THE DELINEATION LINE BETWEEN THE AE6 AND | | | THE AE7 FLOOD ZONES. | | | | | | 3) THE JOB IS A SUBSTANTIAL IMPROVEMENT - FBC EXISTING | | | BUILDING 701.3 FLOOD HAZARD AREAS. | | | IN FLOOD HAZARD AREAS, ALTERATIONS THAT CONSTITUTE | | | SUBSTANTIAL IMPROVEMENT SHALL REQUIRE THAT THE BUILDING | | | COMPLY WITH SECTION 1612 OF THE FLORIDA BUILDING CODE, | | | BUILDING, OR SECTION R322 OF THE FLORIDA BUILDING CODE, | | | RESIDENTIAL, AS APPLICABLE. | | | FBC EXISTING BUILDING SECTION202 - SUBSTANTIAL | | | IMPROVEMENT. FOR THE PURPOSE OF DETERMINING COMPLIANCE | | | WITH THE FLOOD PROVISIONS OF THIS CODE, ANY REPAIR, | | | ALTERATION, ADDITION, OR IMPROVEMENT OF A BUILDING OR | | | STRUCTURE, THE COST OF WHICH EQUALS OR EXCEEDS 50 | | | PERCENT OF THE MARKET VALUE OF THE STRUCTURE, BEFORE | | | THE IMPROVEMENT OR REPAIR IS STARTED. | | | | | | 4) THE ENTIRE BUILDING WILL NEED TO BE ELEVATED TO 2 | | | FEET ABOVE THE FEMA BASE FLOOD ELEVATION - | | | ORDINANCE NO. 4729-17 SECTION 4 SEC. 18-33 - TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL. | | | | | | (A) R322.2.1 ELEVATION REQUIREMENTS. | | | | | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES | | | SHALL HAVE THE LOWEST FLOORS ELEVATED TO OR ABOVE THE | | | BASE FLOOD ELEVATION PLUS TWO | | | FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER IS | | | HIGHER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-03-21 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-03-21 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-31 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-31 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2023-01-31 10:55:48 | ELECTRICAL MAIN HOUSE ONLY - SEPARATE PERMIT REQUIRED | | | FOR ACCESSORY STRUCTURE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2023-02-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-17 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-17 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-27 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-27 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2023-01-27 07:30:21 | GAS MAIN HOUSE ONLY - SEPARATE PERMIT REQUIRED FOR | | | ACCESSORY STRUCTURE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-03-28 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-28 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-03-14 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-14 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-31 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-29 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-28 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-03-16 |
Time |
06:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-14 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-01-24 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-31 |
Time |
06:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-31 |
Time |
06:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-17 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-17 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2023-03-17 10:23:15 | 2ND REVIEW FMC | | | PERMIT: 23010885 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | GARAGE APPROVED. ME 3/20/2023 | | | | | | 1) THE BACKDRAFT DAMPER SHOWN ON SHEET M5.2 DETAIL 15 | | | IS NOT CODE COMPLIANT. THE BACKDRAFT DAMPER IS AN | | | INTEGRAL PART OF THE EXHAUST DUCT TERMINATION SEE CODE | | | SECTION BELOW. | | | | | | M1502.3 DUCT TERMINATION. EXHAUST DUCT TERMINATIONS | | | SHALL BE EQUIPPED WITH A | | | BACKDRAFT DAMPER. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-26 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-26 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2023-01-26 12:58:06 | 1ST REVIEW FMC | | | PERMIT: 23010885 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | GARAGE | | | | | | 1) THE GARAGE STRUCTURE WILL REQUIRE A SEPARATE PERMIT. | | | THE DOCUMENTS FOR BOTH STRUCTURES CAN BE SUBMITTED | | | UNDER THIS PERMIT APPLICATION. | | | | | | 2) PROVIDE THE ENERGY CALCULATIONS FOR THE GARAGE | | | STRUCTURE INDEPENDENT FROM THE MAIN HOUSE. THE ENERGY | | | CALCULATIONS FOR THE GARAGE SHOULD INCLUDE THE GARAGE | | | DOORS. FEC R101.5.1.1.1 | | | | | | 3) PROVIDE THE MECHANICAL SIZING CALCULATIONS FOR THE | | | GARAGE AND LIVING SPACE ABOVE. FEC R403.7 | | | | | | 4) THE BATHROOM IN THE GARAGE SHALL HAVE A WINDOW WITH | | | AGGREGATE GLAZING AREA OF NOT LESS THAN 3 FEET, | | | ONE-HALF OF WHICH MUST BE OPERABLE. PROVIDE THE SIZE OF | | | THIS WINDOW ON THE DRAWING. FRC R303.3 | | | | | | 5) THE AHU-5 CONDENSING UNIT LOCATION MUST BE SHOWN ON | | | THE DRAWING. FBC 107.3.5 | | | | | | | | | MAIN HOUSE | | | | | | 1) PROVIDE THE ENERGY CALCULATION FOR THE MAIN HOUSE | | | ONLY. FEC R101.5.1.1.1 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THE MAIN HOUSE ONLY. FEC R 403.7 | | | | | | 3) SHEET M-5.2: ADJUST DETAIL 15 TO COMPLY WITH FRC | | | M1502.3 DUCT TERMINATION. EXHAUST DUCT TERMINATIONS | | | SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. THE | | | BACKDRAFT DAMP SHOULD BE INCLUDED IN THE DUCT | | | TERMINATION MOUNTED ON THE ROOF. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-20 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-20 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2023-03-20 13:46:05 | NOT A SUBSTANTIAL IMPROVEMENT | | | AE 6 | | | APPRAISAL PROVIDED SHOWING BUILDING VALUE 4,700,00.00 / | | | 2 = 2,350,000.00 | | | JOB COST = 1,015,000.00 | | | 5YR COMULATIVE = 0 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-17 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-17 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-27 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-27 |
Time |
06:47 |
Sent To |
|
|
| Notes |
| 2023-01-27 06:57:10 | PLUMBING MAIN HOUSE ONLY - SEPARATE PERMIT REQUIRED FOR | | | ACCESSORY STRUCTURE |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-02-09 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-02-09 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-31 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-31 |
Time |
06:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-20 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-20 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2023-03-17 10:23:50 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-21 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-21 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2023-01-26 12:58:40 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-03-28 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-28 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
AHamilto |
Date |
2023-03-14 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-14 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|