Plan Review Details - Permit 23010816
Plan Review Stops For Permit 23010816
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-08 Cont ID  
Sent By pvalenti Date 2023-05-08 Time 07:18 Rev Time 0.00
Received By pvalenti Date 2023-05-08 Time 06:36 Sent To  
Notes
2023-05-08 07:26:17PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 DO NOTE EXCEED THE LIMITATIONS FOR GUARD OPENINGS OF
 LESS THAN 4" AND EXCEPTION OF LESS THAN 4 3/8" AT OPEN
 SIDE OF STAIRS AS PER SECTION 312.1.3 OF THE FBC
 RESIDENTIAL CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-08 Cont ID  
Sent By shill Date 2023-02-08 Time 10:52 Rev Time 0.00
Received By pvalenti Date 2023-02-08 Time 10:26 Sent To  
Notes
2023-02-08 11:42:11PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL G
  
 BUILDING REVIEW DENIED:
  
  
 1.) NOTICE: ALL PLAN PAGES NEED TO HAVE A VALID
 SIGNATURE/SEAL, SEE BELOW:
  
 A.) DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND
 SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A
 VALID DIGITAL SIGNATURE.
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C.
 B.) SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  
 2.) FBC B 107.2.1, PROVIDE DIMENSIONS OF LANDINGS AND
 STAIR WIDTH.
  
 3.) FBC B 107.2.1, PROVIDE DETAILS OF FINISH DECKING
 (EXAMPLE 2"X 6" P.T. OR 5/4" P.T. DECK BOARDS).
  
 4.) FBC B 107.2.1, PROVIDE CONNECTION DETAILS FOR 2"X
 6" JOIST TO 2"X 8" SIDE GIRDERS.
  
 5.) FBC B 107.2.1 & FBC B 1607.8.1.1, PROVIDE MORE
 DETAILS OF HAND RAILS INCLUDING CONNECTIONS. INDICATE
 ON PLANS THAT THE HANDRAILS SHALL BE DESIGNED TO RESIST
 A CONCENTRATED LOAD OF 200 POUNDS IN ACCORDANCE WITH
 ASCE-7.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-08 Cont ID  
Sent By pvalenti Date 2023-05-08 Time 07:26 Rev Time 0.00
Received By pvalenti Date 2023-04-26 Time 16:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-08 Cont ID  
Sent By pvalenti Date 2023-02-08 Time 11:47 Rev Time 0.00
Received By pvalenti Date 2023-01-26 Time 13:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-08 Cont ID  
Sent By pvalenti Date 2023-05-08 Time 07:26 Rev Time 0.00
Received By pvalenti Date 2023-05-08 Time 06:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-02-08 Cont ID  
Sent By pvalenti Date 2023-02-08 Time 10:43 Rev Time 0.00
Received By pvalenti Date 2023-02-08 Time 10:26 Sent To  
Notes
2023-02-08 10:48:42PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 SIGNATURE REVIEW DENIED:
  
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-01 Cont ID  
Sent By vbroglia Date 2023-05-01 Time 14:38 Rev Time 0.00
Received By vbroglia Date 2023-05-01 Time 14:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-02-06 Cont ID  
Sent By vbroglia Date 2023-02-06 Time 13:14 Rev Time 0.00
Received By vbroglia Date 2023-02-06 Time 13:14 Sent To  
Notes
2023-02-06 13:19:042/6/2023 FAILED
  
 PLEASE PROVIDE A SITE PLAN OR SURVEY INDICATING THE
 LOCATION OF THE DECK AREA, PLEASE PROVIDE SETBACKS FROM
 THE PROPERTY LINE
  
 **** REVIEWD BY ****
 VALENTINA BROGLIA
 PLANNER
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved