Plan Review Details - Permit 23010806
| Plan Review Stops For Permit 23010806 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-25 |
Time |
05:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-24 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-23 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2023-01-23 16:14:11 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: THE TENT WIND LOAD CALCULATIONS SUBMITTED FOR | | | REVIEW ARE FOR A 20X40 TENT. SUBMIT ENGINEERING FOR THE | | | 30X60 TENT THATS BEING INSTALLED. | | | | | | 1. FOR TEMPORARY MEMBRANE STRUCTURES (TENTS) WITH A | | | SPAN OF 40 FEET OR GREATER IN ANY DIRECTION: | | | | | | A. PROVIDE DETAILS OF STRUCTURAL CONNECTIONS. INCLUDE | | | BASEPLATE/TIEDOWN DETAILS. | | | B. PROVIDE STRUCTURAL EVALUATION PER FBC CHPT 16/ ASCE | | | 7-16 OF STRUCTURE. | | | | | | THESE DOCUMENTS SHALL BE REVIEWED, SIGNED AND SEALED BY | | | A DESIGN PROFESSIONAL. (SEE SIGNATURE REVIEW COMMENTS) | | | | | | NO EXCEPTIONS BY ORDER OF THE BUILDING OFFICIAL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-18 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2023-01-18 16:19:48 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. FOR TEMPORARY MEMBRANE STRUCTURES (TENTS) WITH A | | | SPAN OF 40 FEET OR GREATER IN ANY DIRECTION: | | | | | | A. PROVIDE DETAILS OF STRUCTURAL CONNECTIONS. INCLUDE | | | BASEPLATE/TIEDOWN DETAILS. | | | B. PROVIDE STRUCTURAL EVALUATION PER FBC CHPT 16/ ASCE | | | 7-16 OF STRUCTURE. | | | | | | THESE DOCUMENTS SHALL BE REVIEWED, SIGNED AND SEALED BY | | | A DESIGN PROFESSIONAL. (SEE SIGNATURE REVIEW COMMENTS) | | | | | | NO EXCEPTIONS BY ORDER OF THE BUILDING OFFICIAL | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-18 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2023-01-18 15:58:20 | FIRE COMMENTS: | | | | | | NO COOKING, BBQS, OPEN FLAMES NOR | | | PROPANE HEATERS UNDER THE TENTS | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
16:20 |
Rev Time |
|
| Received By |
cthroop |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-25 |
Time |
05:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-25 |
Time |
05:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-23 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-18 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2023-01-18 16:20:33 | TENT WIND LOAD CALC'S SHALL BE SIGNED AND SEALED BY A | | | DESIGN PROFESSIONAL. CT |
|
|
|