Plan Review Details - Permit 23010640
| Plan Review Stops For Permit 23010640 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-13 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-13 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2023-02-13 14:02:41 | UPDATED PERMIT APPLICANT UPLOADED, ADDRESS APPROVED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-07 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-07 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2023-02-07 13:27:04 | UNIT 404 HAS BEEN MENTIONED FOR THIS PERMIT HOWEVER I | | | BELIEVE THAT THE ADDRESS FOR THE SCOPE OF WORK IS FOR | | | 404 57TH ST AND NOT 5715 N FLAGLER DR UNIT 404, PLEASE | | | CONFIRM THAT THAT IS THE CORRECT ADDRESS. PLEASE | | | CONTACT [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-21 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-07 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-06 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-21 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-21 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2023-02-07 07:34:37 | 1ST REVIEW FMC | | | PERMIT: 23010640 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THERE APPEARS TO BE MORE THAN ONE STRUCTURE ON THIS | | | PROPERTY. IDENTIFY WHICH STRUCTURE IS TO RECEIVE THIS | | | NEW MECHANICAL SYSTEM. FBC 107.3.5 | | | | | | 2) OUR RECORDS DO NOT SHOW THERE WAS EVER A MECHANICAL | | | SYSTEM PERMITTED FOR THIS ADDRESS. PROVIDE THE ENERGY | | | CALCULATIONS FOR THIS PROJECT. FEC 101.5.1.1 | | | | | | 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS PROJECT. FRC M1401.3 | | | | | | 4) THE CONDENSER MODEL NUMBERS ON THE DRAWING DO NOT | | | MATCH WHAT IS ON THE SUBMITTED AHRI SHEET. THEY WILL | | | NEED TO MATCH. FBC 107.3.5 | | | | | | 5) THE DESIGNER OF THE DRAWING MUST PRINT AND SIGN | | | THEIR NAME ON THE DRAWING. FBC 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
|