Plan Review Details - Permit 23010638
Plan Review Stops For Permit 23010638
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-05 Cont ID  
Sent By lbond Date 2023-06-05 Time 16:41 Rev Time 0.00
Received By lbond Date 2023-06-05 Time 16:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-05-15 Cont ID  
Sent By lbond Date 2023-05-15 Time 10:22 Rev Time 0.00
Received By lbond Date 2023-05-15 Time 10:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-06-05 Cont ID  
Sent By ppetty Date 2023-06-05 Time 10:59 Rev Time 0.00
Received By ppetty Date 2023-06-05 Time 10:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-15 Cont ID  
Sent By ppetty Date 2023-05-15 Time 08:24 Rev Time 0.00
Received By ppetty Date 2023-05-15 Time 08:13 Sent To  
Notes
2023-05-15 08:27:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-13 Cont ID  
Sent By asangele Date 2023-06-13 Time 09:55 Rev Time 0.00
Received By asangele Date 2023-06-13 Time 09:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-25 Cont ID  
Sent By aoliver Date 2023-05-25 Time 08:52 Rev Time 0.00
Received By aoliver Date 2023-05-12 Time 07:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-06-05 Cont ID  
Sent By ccole Date 2023-06-05 Time 10:39 Rev Time 0.00
Received By ccole Date 2023-06-05 Time 10:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By ccole Date 2023-05-19 Time 15:54 Rev Time 0.00
Received By ccole Date 2023-05-19 Time 15:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-05 Cont ID  
Sent By ppetty Date 2023-06-05 Time 11:03 Rev Time 0.00
Received By ppetty Date 2023-06-05 Time 11:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-15 Cont ID  
Sent By lbond Date 2023-05-15 Time 10:22 Rev Time 0.00
Received By lbond Date 2023-05-15 Time 10:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-06-13 Cont ID  
Sent By asangele Date 2023-06-13 Time 09:55 Rev Time 0.00
Received By asangele Date 2023-06-13 Time 09:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By asangele Date 2023-05-24 Time 10:53 Rev Time 0.00
Received By asangele Date 2023-05-24 Time 10:53 Sent To  
Notes
2023-05-24 10:54:43FAILED
 5/24/2023
  
  
 PLEASE LABEL PPOL EQUIPMENT SETBACK ON SURVEY
  
 ARTICLE X. SECTION 94-305
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR
 FEET INTO A SETBACK.
  
  
  
  
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]