| Plan Review Stops For Permit 23010382 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-15 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-15 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2023-02-15 07:57:31 | FLOOR PLAN RECIEVED AND 730 ACTIVATED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-14 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-14 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2023-02-14 13:42:15 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-01-17 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-01-17 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2023-01-17 07:02:40 | IN 2011 THE SUITES 720 AND 730 MERGED TO CREATE A | | | SINGLE UNIT, SUITE 730 WAS RETIRED AND IS NO LONGER AN | | | ACTIVE SUITE ADDRESS, THE OFFICICIAL ADDRESS FOR THE | | | COMBINED UNITS IS 525 OKEECHOBEE BLVD 720, PLEASE | | | CONTACT [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-14 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-13 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-24 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2023-01-24 11:23:20 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-14 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-13 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-24 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2023-01-24 11:22:38 | | | | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23010382 | | | ADD: 525 OKEECHOBEE BLVD # 730 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. 01/24/23 | | | ACTION: DENIED | | | | | | 1) THE SUBMITTED FLOOR PLANS HAVE THE ADDRESS OF 525 | | | OKEECHOBEE BLVD. # 730 BUT NOT THE APPLICATION. SEE | | | ADDRESS STOP FOR STEPS REQUIRED TO GET SUITE 730 | | | REASSIGNED. 2020 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-19 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-19 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-18 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2023-01-18 11:44:53 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-14 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-09 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-01-24 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-01-17 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-24 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-13 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-13 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-18 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-18 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2023-01-18 10:44:08 | 1ST REVIEW FMC | | | PERMIT: 23010382 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE DEMO SHEET SHOWS THIS AREA BEING TAKEN BACK TO | | | AN EMPTY UNIT WITH NO INTERIOR WALLS. SHEET M1: PROVIDE | | | THE SPECS FOR THE EXISTING VAV???S.. FBC 107.3.5 | | | | | | 2) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH | | | OCCUPANCY CLASSIFICATION IN THIS TENANT SPACE ACCORDING | | | TO FMC TABLE 403.3.1.1. FMC 403.3.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-18 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-18 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-13 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-13 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-19 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-19 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2023-01-19 16:09:17 | ALL PLANS PASSED SIGNATURE REVIEW.MP | | 2023-01-18 10:44:46 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | | 2023-01-18 10:21:39 | PLUMB PLANS PASSED |
|
|