Plan Review Details - Permit 23010259
| Plan Review Stops For Permit 23010259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-06 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-06 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-11 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2023-01-11 11:03:33 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE REQUIRED HOURLY FIRE RATING FOR THE | | | ADDED STEEL COLUMNS AND BEAM - FBC 601 | | | | | | 2) ROOF TOP EQUIPMENT STANDS AND DUCT - PLEASE SHOW THE | | | CLEARANCE FROM THE TOP OF THE ROOFING TO THE BOTTOM OF | | | THE ROOF TOP EQUIPMENT STAND AND DUCT - FBC 1510.10 | | | | | | 3) PLEASE SHOW IF TERMITE PROTECTION IS REQUIRED AT THE | | | NEW FOUNDATION - FBC 1816.1.2 | | | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE | | | PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL | | | SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL | | | TREATMENT, INCLUDING SPACES BOXED OR FORMED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-23 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-20 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-10 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-03 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-01-24 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-01-09 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-17 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-17 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2023-01-17 10:38:36 | 1ST REVIEW FMC | | | PERMIT: 23010259 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A NOTE ON THE MECHANICAL DRAWINGS STATING | | | THE NEW KITCHEN HOOD WILL REQUIRE A SEPARATE PERMIT | | | APPLICATION ALONG WITH ALL DATA AND DRAWINGS FOR THE | | | HOOD. THE HOOD WILL REQUIRE A SEPARATE REVIEW AS IT | | | WILL NOT BE REVIEWED UNDER THIS SUBMITTAL. PLEASE | | | REMOVE ALL DOCUMENTS ASSOCIATED WITH THE HOOD DESIGN | | | AND SUBMIT THEM UNDER THE HOOD PERMIT. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-10 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-10 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-01-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-11 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2023-01-24 |
Time |
15:24 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2023-01-24 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |