Plan Review Details - Permit 23010156
Plan Review Stops For Permit 23010156
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-16 Cont ID  
Sent By rmcphers Date 2023-03-16 Time 15:09 Rev Time 0.00
Received By rmcphers Date 2023-03-16 Time 15:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-01 Cont ID  
Sent By rmcphers Date 2023-02-01 Time 14:14 Rev Time 0.00
Received By rmcphers Date 2023-02-01 Time 14:14 Sent To  
Notes
2023-02-01 14:17:02FLOOR REPAIR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING S4 IS MISSING - THERE ARE CUT SECTIONS THAT
 REFER TO S4.
  
 2) PLEASE SHOW JOIST ANCHORAGE FBC 107
  
 3) SIGNED AND SEALED DRAWINGS NEED TO BE DIGITALLY
 SIGNED BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
 I CHECK THE ELECTRONIC SIGNATURE BY OPENING THEM IN
 ???ADOBE READER???. THE ???ADOBE READER??? STATES
 WHETHER THEY ARE AN ORIGINAL ELECTRONICALLY SIGNED
 DOCUMENT. WHEN ELECTRONICALLY SIGNED DRAWINGS ARE
 PRINTED OUT, THEY LOSE THEIR ELECTRONIC SIGNATURE.
 ELECTRONICALLY SIGNED DRAWINGS NEED TO BE MOVED AROUND
 IN THE COMPUTER FROM PLACE TO PLACE. FROM THE
 ARCHITECT???S OR ENGINEER???S COMPUTER TO YOUR COMPUTER
 TO THE CITY???S ELECTRONIC PLAN REVIEW (PROJECTDOX).
 MAYBE YOURS WERE PRINTED OUT AT SOME TIME?

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-03-16 Cont ID  
Sent By cwalker Date 2023-03-16 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-01-10 Cont ID  
Sent By cwalker Date 2023-01-10 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-16 Cont ID  
Sent By rmcphers Date 2023-03-16 Time 15:13 Rev Time 0.00
Received By rmcphers Date 2023-03-15 Time 08:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-01 Cont ID  
Sent By rmcphers Date 2023-02-01 Time 14:23 Rev Time 0.00
Received By rmcphers Date 2023-01-09 Time 08:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-16 Cont ID  
Sent By rmcphers Date 2023-03-16 Time 15:09 Rev Time 0.00
Received By rmcphers Date 2023-03-16 Time 15:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-02-01 Cont ID  
Sent By rmcphers Date 2023-02-01 Time 14:17 Rev Time 0.00
Received By rmcphers Date 2023-02-01 Time 14:17 Sent To  
Notes
2023-02-01 14:21:22SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) ALL SIGNED AND SEALED DRAWINGS NEED TO BE DIGITALLY
 SIGNED.
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
 I CHECK THE ELECTRONIC SIGNATURE BY OPENING THEM IN
 ???ADOBE READER???. THE ???ADOBE READER??? STATES
 WHETHER THEY ARE AN ORIGINAL ELECTRONICALLY SIGNED
 DOCUMENT. WHEN ELECTRONICALLY SIGNED DRAWINGS ARE
 PRINTED OUT, THEY LOSE THEIR ELECTRONIC SIGNATURE.
 ELECTRONICALLY SIGNED DRAWINGS NEED TO BE MOVED AROUND
 IN THE COMPUTER FROM PLACE TO PLACE. FROM THE
 ARCHITECT???S OR ENGINEER???S COMPUTER TO YOUR COMPUTER
 TO THE CITY???S ELECTRONIC PLAN REVIEW (PROJECTDOX).
 MAYBE YOURS WERE PRINTED OUT AT SOME TIME?


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved