Plan Review Details - Permit 23010071
Plan Review Stops For Permit 23010071
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-02-02 Cont ID  
Sent By rrossano Date 2023-02-02 Time   Rev Time 0.00
Received By rrossano Date 2023-02-02 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-01-17 Cont ID  
Sent By rrossano Date 2023-01-17 Time   Rev Time  
Received By rrossano Date 2023-01-17 Time   Sent To  
Notes
2023-01-17 11:52:00PLEASE ADDRESS FIRE COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-02-07 Cont ID  
Sent By pleduc Date 2023-02-07 Time   Rev Time 0.00
Received By pleduc Date 2023-02-07 Time 12:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-02-02 Cont ID  
Sent By pleduc Date 2023-02-02 Time   Rev Time 0.00
Received By pleduc Date 2023-02-02 Time 10:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-01-12 Cont ID  
Sent By pleduc Date 2023-01-12 Time   Rev Time 0.00
Received By pleduc Date 2023-01-11 Time 11:51 Sent To  
Notes
2023-01-11 11:51:55THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS A SITE PLAN PROVIDED. HOWEVER, THIS IS NO
 SPECIFIC LOCATION INDICATED FOR THE PROPOSED FIRE LINE.
  
 FOR THE OFFICIAL RECORD AND CLARIFICATIONS, PLEASE
 PROVIDE A HIGHLIGHTED LOCATION FOR THE PROPOSED FIRE
 LINE.
  
  
 1A) THERE ARE NO INDICATIONS OF COMPLIANCE WITH NFPA
 24.
  
 THE PROPOSED SHALL BE INSTALLED, INSPECTED AND TESTED
 PER NFPA AND MANUFACTURES SPECIFICATIONS.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A NOTE
 OF ACKNOWLEDGMENT ON THE PLAN SHEETS.
  
  
 1B) THERE ARE NO MANUFACTURES SPECIFICATION SHEETS FOR
 THE PROPOSED DDCV THAT INDICATES COMPLIANCE WITH NFPA.
  
 PLEASE PROVIDE SPECIFIC DETAILS.
  
  
 1C) ENSURE THE APPLICABLE JOINT RESTRAINTS ARE
 INSTALLED AND TORQUED PER MANUFACTURES SPECS AND JOINTS
 SHALL NOT BE COVERED OVER PRIOR TO FIRE INSPECTION.
  
 A TORQUE WRENCH SHALL BE ON SITE WITH THE INSTALLING
 CONTRACTOR FOR CONFIRMATION AND VERIFICATION AT THE
 TIME OF FIRE INSPECTION.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A NOTE
 OF ACKNOWLEDGMENT ON THE PLAN SHEETS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-02-07 Cont ID  
Sent By lmarchan Date 2023-02-07 Time 16:02 Rev Time 0.00
Received By lmarchan Date 2023-02-06 Time 12:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-03 Cont ID  
Sent By mpeterso Date 2023-02-03 Time 15:46 Rev Time 0.00
Received By mpeterso Date 2023-02-01 Time 17:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-19 Cont ID  
Sent By mpeterso Date 2023-01-19 Time 09:59 Rev Time 0.00
Received By mpeterso Date 2023-01-10 Time 10:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-02-06 Cont ID  
Sent By rgathrig Date 2023-02-06 Time 17:46 Rev Time 0.00
Received By rgathrig Date 2023-02-06 Time 17:46 Sent To  
Notes
2023-02-06 17:47:31VERIFIED SIGNATURE
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-02-03 Cont ID  
Sent By mpeterso Date 2023-02-03 Time 15:38 Rev Time 0.00
Received By mpeterso Date 2023-02-03 Time 15:38 Sent To  
Notes
2023-02-03 15:46:36SIGNATURE REVIEW FAILED
 1) THE DIGITAL SIGNATURE OF THE ENGINEER OF RECORD ON
 ALL DRAWINGS COULD NOT BE CERTIFIED USING ADOBE OR
 BLUEBEAM SOFTWARE. PLEASE CORRECT AS OUTLINED BELOW.
  
 DIGITALLY SUBMITTED DOCUMENTS MUST HAVE A SEAL WITH A
 DIGITAL SIGNATURE. PLEASE NOTE IT IS EXTREMELY
 IMPORTANT THAT ALL DIGITAL SIGNATURES ARE VERIFIABLE
 THROUGH ADOBE OR BLUEBEAM SOFTWARE
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-19 Cont ID  
Sent By mpeterso Date 2023-01-19 Time 09:57 Rev Time 0.00
Received By mpeterso Date 2023-01-19 Time 09:53 Sent To  
Notes
2023-01-19 09:59:49SIGNATURE REVIEW FAILED
 1) PLANS IN BOTH DRAWING AND SIGNATURE FOLDER FAILED
 SIGNATURE REVIEW
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  