Plan Review Details - Permit 23010042
Plan Review Stops For Permit 23010042
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-03-22 Cont ID  
Sent By rwbrown Date 2023-03-22 Time 05:54 Rev Time 0.00
Received By rwbrown Date 2023-03-22 Time 05:54 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2023-03-06 Cont ID  
Sent By rwbrown Date 2023-03-06 Time 10:52 Rev Time 0.00
Received By rwbrown Date 2023-03-06 Time 10:52 Sent To  
Notes
2023-03-06 11:06:15TO ANSWER YOUR QUESTION:
  
 [A] 102.1 GENERAL. WHERE THERE IS A CONFLICT BETWEEN A
 GENERAL
 REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE. WHERE, IN ANY SPECIFIC
 CASE,
 DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT
 MATERIALS,
 METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN.
  
 WHEN THERE ARE TWO MATERIALS BEING USED, THERE ARE TWO
 DIFFERENT TABLES. THE MORE RESTRICTIVE TABLE MUST BE
 USED. YOU CANNOT GET MORE FLOW FROM ONE SECTION OF PIPE
 AND LESS FLOW FROM ANOTHER SECTION OF PIPE AND
 EFFECTIVELY SIZE THE PIPING SYSTEM USING THE LONGEST
 RUN METHOD OR BRANCH METHOD. CSST HAS MORE FRICTION AND
 LOSS THAN METALLIC PIPE. USING THE SAME PRESSURRES AND
 PIPE SIZES SHOWS THAT CSST HAS LESS OUTPUT THAN
 METALLIC PIPE. YOU MUST USE THE MORE RESTRICTIVE TABLE.
  
 IT CONTINUES IN THE APPENDIX THAT EXPLAINS PIPE SIZING
 AND DESCRIBES ONLY USING "ONE LINE FROM ONE SIZING
 TABLE" FOR EACH SYSTEM (WHICH IS FROM REGULATOR TO
 REGULATOR).
  
 WITH THAT BEING SAID, USING TABLE 402.4(5), AT 125 FT
 (THE NEXT LINE CONSIDERING THE LONGEST RUN IS 120) THE
 MAXIMUM LOAD ALLOWED FOR 1/2" PIPE IS 414K BTU, AND YOU
 ARE RUNNING 689K BTU. REGARDLESS OF THE ABOVE
 MENTIONED, YOU ARE UNDERSIZED.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 09:52 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 09:52 Sent To  
Notes
2023-02-28 10:00:071ST GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC G2413.4.1 - WHEN COMBINING MATERIALS SUCH
 AS CSST AND GALVANIZED, AND USING THE LONGEST RUN
 METHOD, YOU CAN ONLY USE ONE SIZING CHART PER "SYSTEM".
 THE 2 POUND SYSTEM USING CHART 402.4(18), IT APPEARS
 YOU ARE UNDERSIZED FOR THE BTU LOAD. (USING THE 150FT
 LINE ON THE CHART). COMPARE THE 2 CHARTS AND USE THE
 MOST RESTRICTIVE.
 A) THE 1ST LEG HAS 689K BTU - AND THE SIZE CHART SAYS
 YOU WOULD HAVE TO HAVE 1" ALL THE WAY TO THE POOL
 HEATER.
 B) AFTER THE POOL HEATER, YOU WOULD NEED AT LEAST 3/4"
 GOING UP THE WALL.
 C) YOU WOULD ALSO NEED 3/4" ALL THE WAY TO THE TWH
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-03-23 Cont ID  
Sent By aoliver Date 2023-03-23 Time 08:34 Rev Time 0.00
Received By aoliver Date 2023-03-15 Time 16:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-06 Cont ID  
Sent By rwbrown Date 2023-03-06 Time 11:06 Rev Time 0.00
Received By rwbrown Date 2023-03-03 Time 15:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-28 Cont ID  
Sent By shill Date 2023-02-28 Time 11:42 Rev Time 0.00
Received By shill Date 2023-02-03 Time 15:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2023-03-22 Cont ID  
Sent By rwbrown Date 2023-03-22 Time 05:54 Rev Time 0.00
Received By rwbrown Date 2023-03-22 Time 05:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2023-03-06 Cont ID  
Sent By rwbrown Date 2023-03-06 Time 09:51 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 10:00 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 09:47 Sent To  
Notes
2023-02-28 10:01:40PLUMBING UNDER MASTER 22070580 AND PLUMBING SUB
 22120103

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-02-28 Cont ID  
Sent By shill Date 2023-02-28 Time 11:42 Rev Time 0.00
Received By shill Date 2023-02-28 Time 11:42 Sent To  
Notes
2023-02-28 11:42:24INSPECTIONS ONLY - DOCS W/MASTER
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 10:02 Rev Time  
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***