Plan Review Details - Permit 23010042
| Plan Review Stops For Permit 23010042 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-03-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-22 |
Time |
05:54 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-22 |
Time |
05:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-06 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-06 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2023-03-06 11:06:15 | TO ANSWER YOUR QUESTION: | | | | | | [A] 102.1 GENERAL. WHERE THERE IS A CONFLICT BETWEEN A | | | GENERAL | | | REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. WHERE, IN ANY SPECIFIC | | | CASE, | | | DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT | | | MATERIALS, | | | METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. | | | | | | WHEN THERE ARE TWO MATERIALS BEING USED, THERE ARE TWO | | | DIFFERENT TABLES. THE MORE RESTRICTIVE TABLE MUST BE | | | USED. YOU CANNOT GET MORE FLOW FROM ONE SECTION OF PIPE | | | AND LESS FLOW FROM ANOTHER SECTION OF PIPE AND | | | EFFECTIVELY SIZE THE PIPING SYSTEM USING THE LONGEST | | | RUN METHOD OR BRANCH METHOD. CSST HAS MORE FRICTION AND | | | LOSS THAN METALLIC PIPE. USING THE SAME PRESSURRES AND | | | PIPE SIZES SHOWS THAT CSST HAS LESS OUTPUT THAN | | | METALLIC PIPE. YOU MUST USE THE MORE RESTRICTIVE TABLE. | | | | | | IT CONTINUES IN THE APPENDIX THAT EXPLAINS PIPE SIZING | | | AND DESCRIBES ONLY USING "ONE LINE FROM ONE SIZING | | | TABLE" FOR EACH SYSTEM (WHICH IS FROM REGULATOR TO | | | REGULATOR). | | | | | | WITH THAT BEING SAID, USING TABLE 402.4(5), AT 125 FT | | | (THE NEXT LINE CONSIDERING THE LONGEST RUN IS 120) THE | | | MAXIMUM LOAD ALLOWED FOR 1/2" PIPE IS 414K BTU, AND YOU | | | ARE RUNNING 689K BTU. REGARDLESS OF THE ABOVE | | | MENTIONED, YOU ARE UNDERSIZED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-28 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-28 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2023-02-28 10:00:07 | 1ST GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC G2413.4.1 - WHEN COMBINING MATERIALS SUCH | | | AS CSST AND GALVANIZED, AND USING THE LONGEST RUN | | | METHOD, YOU CAN ONLY USE ONE SIZING CHART PER "SYSTEM". | | | THE 2 POUND SYSTEM USING CHART 402.4(18), IT APPEARS | | | YOU ARE UNDERSIZED FOR THE BTU LOAD. (USING THE 150FT | | | LINE ON THE CHART). COMPARE THE 2 CHARTS AND USE THE | | | MOST RESTRICTIVE. | | | A) THE 1ST LEG HAS 689K BTU - AND THE SIZE CHART SAYS | | | YOU WOULD HAVE TO HAVE 1" ALL THE WAY TO THE POOL | | | HEATER. | | | B) AFTER THE POOL HEATER, YOU WOULD NEED AT LEAST 3/4" | | | GOING UP THE WALL. | | | C) YOU WOULD ALSO NEED 3/4" ALL THE WAY TO THE TWH | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-23 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-23 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-15 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-06 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-02-03 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-22 |
Time |
05:54 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-22 |
Time |
05:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-06 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-28 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-28 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2023-02-28 10:01:40 | PLUMBING UNDER MASTER 22070580 AND PLUMBING SUB | | | 22120103 |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-02-28 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2023-02-28 11:42:24 | INSPECTIONS ONLY - DOCS W/MASTER | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-28 |
Time |
10:02 |
Rev Time |
|
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|