Plan Review Details - Permit 22121291
| Plan Review Stops For Permit 22121291 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-12 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-12 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2023-07-12 10:17:10 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS A1-312 - DOES NOT SHOW AS DIGITALLY SIGNED | | | IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-26 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-26 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2023-04-26 08:40:50 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A0-102 THE ACCESSIBLE PARKING NEEDS TO BE | | | NEAR THE ELEVATORS AND MATCH DRAWING A1-102 - FBC | | | 208.3.1 | | | | | | 7) DRAWINGS A0-101, A0-103, A0-104, A0-105, A0-107, | | | A1-101,A1-107, A1-108,A1-109,A1-201, A1-206,A1-312, | | | A1-311, A1-321, A1-322, A1-326, A1-327, A1-328, A1-329, | | | A1-320,A2-101, A2-102, A2-103,A2-104, A2-105, A2-106, | | | A2-219, A2-220, A2-221, A2-222, A3-102, A5-101, A5-102, | | | A5-301 - DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2023-01-25 08:35:52 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A0-102 THE ACCESSIBLE PARKING NEEDS TO BE | | | NEAR THE ELEVATORS AND MATCH DRAWING A1-102 - FBC | | | 208.3.1 | | | | | | 2) DRAWING A1-314 - UNIT B1 813 - SHOWER DOES NOT | | | APPEAR TO HAVE THE CLEAR FLOOR SPACE REQUIRED - FBC FHA | | | REQUIREMENT 7 (2) (B) (VII) | | | | | | 3) DRAWING A0-106 - THE OCCUPANT LOAD CHART SHOWS 653 | | | OCCUPANTS - THE DOOR OPENINGS AT 160 PERSONS EACH X 4 = | | | 640 WHICH DOES NOT MEET THE OCCUPANT LOAD - FBC | | | 1005.3.2 | | | | | | 4) DRAWING A1-324 - UNIT A3 PLEASE SHOW THE DIMENSION | | | FBC FHA REQUIREMENT 7 (1) (B) CLEARANCE BETWEEN | | | COUNTERS AND ALL OPPOSING BASE CABINETS, COUNTERTOPS, | | | APPLIANCES OR WALLS IS AT LEAST 40 INCHES. | | | | | | 5) DRAWING A1-325 - UNIT A4 AND A5 PLEASE SHOW THE | | | DIMENSION FBC FHA REQUIREMENT 7 (1) (B) CLEARANCE | | | BETWEEN COUNTERS AND ALL OPPOSING BASE CABINETS, | | | COUNTERTOPS, APPLIANCES OR WALLS IS AT LEAST 40 INCHES. | | | | | | 6) DRAWING A1-106 - FITNESS ROOM - DOOR 703B IS SHOWN | | | AS 2' 8" WHICH IS NOT A USEABLE DOOR WITH A CLEAR WIDTH | | | OF 32" - IT SHOULD BE A USEABLE DOOR WITH 32" CLEARANCE | | | PER FBC FHA REQUIREMENT 2 (14) | | | | | | 7) THE ARCHITECTURAL DRAWINGS - DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-28 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-28 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-03 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-02 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-12 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-04-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-01-23 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-20 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-19 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-24 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-24 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2023-04-24 17:20:47 | 2ND REVIEW FBC-2020 FUEL GAS | | | PERMIT- 22121291 | | | 4/24/2023 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P402: BASED ON THE LOW PRESSURE TABLE 402.4(1) | | | SPECIFIED ON THE DRAWING, PLEASE SHOW MINIMUM 1-INCH | | | GAS PIPES FROM THE REGULATORS TO THE POOL HEATERS. | | | | | | 2) P101A & P402: THE REVISED SHEET P101A SHOWS A 2-INCH | | | MAIN GAS PIPE, THE REVISED RISER SHOWS AN 1-1/4 INCH. | | | PLEASE FIX ONE OR THE OTHER- SEC. 107.2.1 WPB. | | | | | | 3) P101A: THE LOCATION OF THE GAS METER IS NOT SHOWN ON | | | THE REVISED PLAN- SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-25 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-25 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2023-01-25 15:20:23 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 22121291 | | | 1/25/2023 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P105: PLEASE PROVIDE A BRIEF NARRATIVE TO | | | CLARIFY THE CHANGES MADE TO THE GAS PLANS AS INDICATED | | | BY REVISION CLOUD 4 AND SUBMIT ANY OTHER REVISED PLANS | | | OR RISER DRAINGS AFFECTED BY THE CHANGE- SEC. 107.2.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-11 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-04 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-19 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-03 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-01-20 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2023-07-17 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2023-07-17 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-04 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-04 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-24 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-24 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2023-01-24 10:27:37 | 1ST REVIEW FMC | | | PERMIT: 22121291 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL NARRATIVE STATES EQUIPMENT WAS ADDED | | | AND SEVERAL PIECES WERE MOVED THE VALUE OF THE REVISION | | | IS LISTED AS $0, PLEASE PROVIDE THE ADDED VALUE OF | | | THESE REVISIONS. | | | | | | 2) SHEET M4-01: THERE IS NO NEW REVISED DRAWING. THE | | | SHEET SUBMITTED IS THE SAME DRAWING. THEY BOTH ARE FOR | | | REVISION 1 BDC 02-14-2022. PROVIDE THE REVISED DRAWING | | | FOR THE REVISION MENTION ON THE NARRATIVE SHEET. FBC | | | 107.3.5 | | | | | | 3) SHEET M4-02: THERE IS NO NEW REVISED DRAWING. THE | | | SHEET SUBMITTED IS THE SAME DRAWING. THEY BOTH ARE FOR | | | REVISION 1 BDC 02-14-2022. PROVIDE THE REVISED DRAWING | | | FOR THE REVISION MENTION ON THE NARRATIVE SHEET. FBC | | | 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-20 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-19 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2023-07-20 10:02:18 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22121291 | | | 7/20/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P101A: PROVIDE A VENT FOR THE FLOOR DRAIN IN THE PET | | | WASH 129 ROOM- SEC. 901.2.1 FBC P. | | | | | | 2) P310: CONCERNING THE USE OF THE SOVENT SYSTEM, THE | | | SYSTEM IS DEFINED AS AN ALTERNATIVE ENGINEERED DESIGN | | | WHICH REQUIRES THE ENGINEER OF RECORD TO SUBMIT | | | TECHNICAL DATA TO SUBSTANTIATE THE PROPOSED ALTERNATIVE | | | DESIGN AND TO PROVE THE PERFORMANCE MEETS THE INTENT OF | | | THE CODE- SEC. 316.1.3. PLEASE PROVIDE THE FOLLOWING | | | ITEMS- | | | | | | A) ENGINEER'S LETTER TO THE BUILDING OFFICIAL WITH | | | SUFFICIENT EVIDENCE TO REQUEST APPROVAL OF THE | | | ALTERNATIVE SYSTEM. | | | | | | B) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS WITH ENGINEER'S APPROVAL STAMP. | | | | | | C) SITE SPECIFIC INSTALLATION DETAILS ON THE PLANS. | | | | | | D) REVISED RISER DRAWINGS. THE REVISED SHEET 310 SHOWS | | | SOVENT DEAERATORS INSTALLED AT RISERS SS-1, 6, 8, 12, | | | 15, 18, 22, 25, 27, 28, 33, 41, 54, 60, 62, 66, 69, 72 | | | & 76. PLEASE SUBMIT REVISED RISER PLANS SHEETS P305, | | | P306, P307, P308, P309 SHOWING THE NEW SOVENT | | | DEAERATORS AT THE RISERS. PLEASE NOTE RELIEF VENTS ARE | | | REQUIRED FOR WASTE AND SOIL STACKS HAVING MORE THAN 10 | | | BRANCH INTERVALS.THE REVISED DRAWINGS SHALL SHOW | | | COMPLIANCE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-24 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-24 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2023-04-24 16:56:43 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22121291 | | | 4/24/2023 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P101A: THE REVISED SHEET SHOWS SOME KEY ITEMS | | | HAVE BEEN CHANGED OR DELETED. PLEASE PROVIDE A COMPLETE | | | NARRATIVE TO CLARIFY THE FOLLOWING ITEMS. | | | A) DOMESTIC AND IRRIGATION WATER SERVICE ENTRANCE | | | LOCATIONS ARE NOT SHOWN. | | | B) BUILDING DRAINS AND SEWER DRAIN SIZES HAVE BEEN | | | REDUCED ON THE EAST SIDE. | | | C) DFU CALCULATIONS HAVE BEEN REMOVED. | | | D) SEWER DRAIN CLEANOUT LOCATIONS HAVE BEEN REMOVED ON | | | THE EAST SIDE. | | | E) FLOOR DRAIN REMOVED FROM THE PET WASH. | | | F) GAS METER LOCATION REMOVED. | | | | | | 2) P101A: BASED ON THE CHANGES SHOWN PLEASE SUBMIT A | | | REVISED SANITARY ISOMETRIC DRAWING- SEC. 107.2.1 WPB. | | | | | | 3) P105: PLEASE PROVIDE A CLOUD AND REVISION NUMBER TO | | | SHOW THE LOCATION OF THE NEW PANTRY SINK ON THE FLOOR | | | PLAN- SEC. 107.2.1 WPB. | | | | | | 4) P105: PLEASE REPLACE THE REMOVED UNIT IDENTIFICATION | | | NUMBERS- SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-25 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-23 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2023-01-25 15:12:18 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22121291 | | | 1/25/2023 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SEC. 107.2.1 WPB: REVISION NARRATIVE #4 SUBMITTED BY | | | JGP ENGINEERING GROUP DOES NOT LIST ALL THE REVISED | | | SHEETS IN THE SET AND DOES NOT PROVIDE ANY EXPLANATION | | | FOR THE CHANGES MADE TO THE PLAN. PLEASE PROVIDE A | | | COMPLETE NARRATIVE THAT CLARIFIES ALL CHANGES MADE TO | | | THE ORIGINAL PLANS- SEC. 107.2.1 WPB. | | | A) MISSING FROM THE NARRATIVE ARE THE UPLOADED SHEETS | | | P101A, P103, P105, P106, P202, P203, P204 & P204A. | | | B) SHEETS LISTED IN THE NARRATIVE THAT ARE MISSING FROM | | | THE PLAN SETS ARE- P101, P106A, P107 & P108. | | | | | | 2) P106 & P202: PLEASE PROVIDE REVISION CLOUDS AND | | | DATES ON P106 TO HIGHLIGHT THE CHANGES MADE TO THE B-1 | | | BATHROOMS AS SHOWN ON P202- SEC. 107.2.1 WPB. | | | | | | 3) P202 UNIT B1: BASED ON PAGE 7.58 FAIR HOUSING DESIGN | | | ACT MANUAL, THE NEW SHOWER DEPTH DIMENSION SHALL BE | | | MINIMUM 36-INCHES. THE DRAWING SHOWS 2 FT- 8 INCHES. | | | | | | A) PROVIDE A 30-INCH X 48-INCH CLEAR FLOOR SPACE | | | DIAGRAM POSITIONED FOR A PARALLEL APPROACH TO THE NEW | | | SHOWER AND FLUSH WITH THE CONTROL WALL. PLEASE NOTE NO | | | OTHER FIXTURES MAY OBSTRUCT THE CLEAR FLOOR SPACE | | | REQUIRED FOR THE SHOWER EXCEPT A LAVATORY MAY OVERLAP A | | | MAXIMUM OF 6-INCHES IF KNEE SPACE IS PROVIDED IN THE | | | OVERLAP OR A REMOVABLE CABINET- PAGES 7.56-7.578 FHDA | | | MANUAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-12 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-12 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2023-07-12 10:19:15 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS A1-312, M101, M102, M104, M105A, M105B, | | | M106A, M200, M203, M204, M205, M206, M207, M300, M403 - | | | DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-26 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-26 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2023-04-26 08:45:35 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS A0-101, A0-103, A0-104, A0-105, A0-107, | | | A1-101,A1-107, A1-108,A1-109,A1-201, A1-206,A1-312, | | | A1-311, A1-321, A1-322, A1-326, A1-327, A1-328, A1-329, | | | A1-320,A2-101, A2-102, A2-103,A2-104, A2-105, A2-106, | | | A2-219, A2-220, A2-221, A2-222, A3-102, A5-101, A5-102, | | | A5-301, M101, M102, M104, M105A, M105B, M106A, M200, | | | M203, M204, M205, M206, M207, M300, M403 - DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2023-01-25 09:05:03 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ALL OF THE ARCHITECTURAL DRAWINGS AND M1-01, M1-02, | | | M1-04, M1-05A, M1-05B, M1-06A, M2-00 M1-03, M2-04, | | | M2-05, M2-06, M2-07, M3-00, M4-01, M4-03 DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | 2023-01-24 10:25:55 | ALL MECHANICAL SHEETS EXCEPT FOR M103, M107 AND M402 | | | NEED THE DESIGNERS DIGITAL SIGNATURE. ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2023-02-24 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2023-02-24 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2023-02-24 12:34:06 | PRIOR TO CO, PLEASE SUBMIT AN APPLICATION FOR A MINOR | | | SITE PLAN AMENDMENT AND PROVIDE THE AS-BUILT DRAWINGS. |
|
|
|