| Plan Review Stops For Permit 22121260 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-28 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-22 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2023-02-28 14:05:54 | HALF ADDRESS RETIRED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-14 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-14 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2023-02-14 14:12:40 | RESPONCE TO COMMENTS STATE THAT THE WORK IS BEING DONE | | | ON 522 NORTHWOOD RD. HALF ADDRESS ISSUE STILL | | | OUTSTANDING, PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO DISCUSS | | | ADDRESS ISUES. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-01-03 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-01-03 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2023-01-03 13:06:13 | THREE ADDRESSES ON THIS PARCEL, 522, 522 1/2 AND 524 | | | NORTHWOOD RD, PLEASE CONFIRM WHICH UNITS ARE INCLUDED | | | IN THIS SCOPE OF WORK, ALSO PLEASE HAVE THE BUILDING | | | OWNER CONTACT ME SO THAT THE HALF ADDRESS CAN BE | | | READDRESSED, PLEASE EMAIL [email protected] OR CALL | | | 561-805-6659. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-14 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-13 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2023-02-13 09:24:05 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING | | | THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS | | | PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM | | | BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION | | | WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-17 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2023-01-17 16:24:14 | | | | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING | | | THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS | | | PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM | | | BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION | | | WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-14 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-13 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-13 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2023-02-13 09:47:37 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT:22121260 | | | ADD: 522 NORTHWOOD RD. | | | CONT: DANIEL CHASE DEVELOPMENT | | | TEL: 561-718-0747 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. FEB. 13TH/2023 | | | ACTION: BUILDING PROVISOS: | | | | | | 1) BUILDING PROVISO: 2020 FBC-ACCESSIBILITY CODE FIGURE | | | 604.8.1.6 SHOWS AN OUTSWING DOOR. PLEASE REVIEW SECTION | | | 603.2.3. EXCEPTION 2. WHERE TOILET ROOMS ARE FOR | | | INDIVIDUAL USE AND A CLEAR FLOORS SPACE COMPLYING WITH | | | 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE | | | DOOR SWING. | | | | | | 2) BUILDING PROVISOS: 2020 FBC-ACCESSIBILITY CODE | | | FIGURE 604.8.1.6 SHOWS AN OUTSWING DOOR. PLEASE REVIEW | | | SECTION 603.2.3. DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE OR CLEARANCES REQUIRED FOR ANY FIXTURE. | | | DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED | | | TURNING SPACE. PLEASE SEE EXCEPTION 2. WHERE TOILET | | | ROOMS ARE FOR INDIVIDUAL USE AND A CLEAR FLOORS SPACE | | | COMPLYING WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND | | | THE ARC OF THE DOOR SWING. WHAT IS MISSING IS THE | | | REQUIRED 30X48 INCH CLEAR FLOOR SPACE BEYOND THE ARC OF | | | THE DOOR. USUALLY AT A 45% ANGLE TO THE DOOR ENTRANCE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-17 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2023-01-17 17:18:40 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT:22121260 | | | ADD: 522 NORTHWOOD RD. | | | CONT: DANIEL CHASE DEVELOPMENT | | | TEL: 561-718-0747 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JAN. 17TH/2023 | | | ACTION: DENIED | | | 1) THE COVERSHEET INDICATES THE SCOPE OF WORK NEW | | | TENANT IMPROVEMENTS FOR AN EXISTING BEAUTY STUDIO. | | | PLEASE NOTE TO DATE THERE HAS NEVER BEEN A LICENSED | | | BEAUTY SALON AT THIS ADDRESS, IT APPEARS ALL NEW WORK. | | | REVIEWING THE PERMITS PULLED IN THE PAST FOR THIS | | | ADDRESS WE DO NOT FIND PERMITS FOR A BEAUTY SALON. | | | | | | 2) THE OCCUPANCY LOAD FACTOR IS BEING FIGURED AT 150 | | | SQ. FT./ OCCUPANT. YOU ROUNDED DOWN BUT YOU SHOULD | | | ROUND UP TO THE NEXT FULL PERSON. SHEET A-2 SHOWS 4 | | | CHAIRS FOR NAILS 12 CHAIRS FOR HAIR A RECEPTIONIST 2 | | | WAX SERVICE ROOMS AND THAT IS WITHOUT EMPLOYEES FOR | | | NAILS OR HAIR ATTENDANTS THE INCREASED OCCUPANT LOAD IS | | | CLOSER TO 24 PEOPLE. 2020 FBC-BUILDING 1004.2 THIS IS | | | CLOSER TO THE DESIGN OCCUPANT LOAD OF THIS FOOTPRINT. | | | WITH THE HIGHER OCCUPANT LOAD THIS MAY AFFECT THE | | | REQUIRED FRESH AIR REQUIRED. | | | | | | 3) SHEET A-1.THE FLOOR PLAN INDICATES THE UNISEX | | | RESTROOM IS EXISTING THE PLANS DO NOT PROVIDE WALL | | | FINISHES. 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS & | | | SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED | | | A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | | | 4) THE FLOOR PLAN A-1 INDICATES A NEW HAND SINK, PLEASE | | | PROVIDE THE HEIGHT OF THE RIM OF THE SINK. 2020 | | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES | | | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE | | | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-03-15 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-03-15 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-02-13 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-02-13 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-12 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-11 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2023-01-12 09:34:28 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE NON-DWELLING LOAD CALCULATION IN ACCORDANCE | | | WITH NEC 220 TO CONFIRM CAPACITY IS ADEQUATE FOR | | | EXISTING ELECTRICAL PANELS A AND B, AND EXISTING | | | SERVICES A AND B.. | | | NOTE: IT IS A BARBER SHOP AND BEAUTY PARLOR WITH SHOW | | | WINDOW AND KITCHEN. | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-13 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-12-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-12-29 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2022-12-29 11:39:57 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF NAIL STATIONS; HOWEVER, I | | | DO NOT SEE MECHANICAL PLANS INDICATING THE MINIMUM CFM | | | REQUIREMENTS AT EACH STATION. | | | | | | PER FLORIDA ADMINSTRATIVE CODE | | | | | | 61G5-20.002 SALON REQUIREMENTS. | | | | | | 1. VENTILATION AND CLEANLINESS: EACH SALON SHALL BE | | | KEPT WELL VENTILATED. .....EACH SALON WHICH PROVIDES | | | SERVICES FOR THE EXTENDING OR SCULPTURING OF NAILS | | | SHALL PROVIDE SUCH SERVICES IN A | | | SEPARATE AREA WHICH IS ADEQUATELY VENTILATED FOR THE | | | SAFE DISPERSION OF ALL FUMES RESULTING FROM THE | | | SERVICES. | | | | | | ANY PROPOSED VENTILATION SYSTEM SHALL COMPLY WITH THE | | | APPLICABLE REQUIRERMENTS OF NFPA 90A. | | | | | | PLEASE REVIEW AND FOR THE OFFICIAL RECORD, PLEASE | | | PROVIDE THE DETAILS SHOWING COMPLIANCE WITH THE | | | MECHAINCAL CODE. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-19 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-11 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-14 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-05 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-17 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-07 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-15 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-10 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-01-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2022-12-28 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-17 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-19 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-19 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-14 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-14 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2023-04-14 08:31:09 | 4TH REVIEW FMC | | | PERMIT: 22121260 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS NAIL SALON REQUIRES A TOTAL OF 693 CFMS OF | | | OUTDOOR AIR FOR THE 28 PEOPLE AND THE SPACE. | | | | | | 2) THIS NAIL SALON ALSO REQUIRES A TOTAL OF 663 CFMS OF | | | EXHAUST. THE 50 CFMS FOR THE STATIONS CAN BE PART OF | | | THIS TOTAL IF WHERE ONE OR MORE REQUIRED SOURCE CAPTURE | | | SYSTEMS OPERATE CONTINUOUSLY DURING OCCUPANCY, THE | | | EXHAUST RATE FROM SUCH SYSTEMS SHALL BE PERMITTED TO BE | | | APPLIED TO THE EXHAUST FLOW RATE REQUIRED BY TABLE | | | 403.3.1.1 FOR THE NAIL SALON. PLEASE SHOW IF ALL OR | | | SOME WILL BE CONTINUOUS ON THE DRAWING. WE MUST ALSO | | | COUNT THE BATHROOM EXHAUST WHICH IS SHOWN IN THE BATH | | | FAN SCHEDULE TO BE 110 CFMS WHICH WOULD MEAN THE TOTAL | | | REQUIRED EXHAUST FOR THIS SPACE IS 773 CFMS. | | | | | | 3) SHEET M-1: THE RTUS INDICATED TO BE 2-TON UNITS. | | | PROVIDE THE SPECS FOR THESE UNITS INDICATING THE | | | OUTDOOR AIR THAT CAN BE BROUGHT IN FROM THE | | | MANUFACTURE. TYPICALLY, A 5-TON UNIT CAN ONLY CONDITION | | | 350 CFMS OF OUTDOOR AIR. | | | | | | 4) SHEET M-2 EXHAUST DETAILS 5 STATES; EXHAUST OF ALL | | | EXTRACTED AIR FROM THE NAIL SALON TO THE OUTDOOR | | | ATMOSPHERE. | | | | | | 5) THIS NAIL SALON IS REQUIRED TO HAVE 693 CFMS OF | | | OUTDOOR AIR BROUGHT IN FOR THE 28 PEOPLE AND THE SPACE. | | | THIS NAIL SALON IS ALSO REQUIRED TO EXHAUST 763 CFMS OF | | | AIR. PLEASE SHOW HOW THIS WILL BE BALANCED. FMC | | | 403.3.1.5 | | | | | | 6) SHEET M-1: PLEASE EXPLAIN THE 4 INCH DUCT AUTO FRESH | | | AIR DAMPER AND DUCT. THE UNITS CONDITIONING THE SPACE | | | ARE RTUS. WHAT IS THE PURPOSE OF THIS DUCT? IF THIS IS | | | BRINGING AIR INTO THE SPACE IT WILL NEED TO BE | | | CONDITIONED AS HUMIDITY WILL BE AN ISSUE. | | | | | | 7) SHEET M-1: THE RTUS INDICATED TO BE 2-TON UNITS. | | | PROVIDE THE SPECS FOR THESE UNITS INDICATING THE | | | OUTDOOR AIR THAT CAN BE BROUGHT IN FROM THE | | | MANUFACTURE. TYPICALLY, A 5-TON UNIT CAN ONLY CONDITION | | | 350 CFMS OF OUTDOOR AIR. THE CLOUD ON THE DRAWINGS | | | INDICATE 430 CFMS IS BEING INTRODUCED TO THE RETURN AIR | | | SYSTEM. HOW WILL THIS AIR BE INTRODUCED AND THEN | | | CONDITIONED BY THE 2 2-TON RTUS? | | | | | | | | | | | | 8) SUMMARY: | | | PROVIDE A COMPLETE DESIGN FOR THE NAIL EXHAUST SYSTEM. | | | IT APPEARS THAT THE 430 CFMS THAT IS BEING INTRODUCED | | | TO EACH RTU ON SHEET M-1 IS ALSO MIXING WITH THE RETURN | | | AIR FROM THE SPACE: SHEET M-2 DETAIL 4. THERE IS NO | | | RETURN AIR DUCT SYSTEM SHOWN ON M-1. THE RTU BRINGS | | | OUTDOOR AIR FROM OUTSIDE, HOW IS THIS ADDITIONAL AIR | | | BEING CONDITIONED FROM THESE 2-TON RTUS? HOW MUCH | | | OUTDOOR AIR ARE THE RTUS BRINGING INTO THIS SPACE? HOW | | | WILL THE 2-TON RTUS CONDITION THE ADDITIONAL 860 CFMS? | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-08 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-08 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2023-03-08 17:44:50 | 3RD REVIEW FMC | | | PERMIT: 22121260 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEWLY ADDED DRYER DUCT MATERIAL SHALL MEET THE | | | MATERIAL REQUIREMENTS OF FMC 504.8.1 | | | | | | 2) PROVIDE A DETAIL DRAWING OF THE MANICURE AND | | | PEDICURE STATIONS EXHAUST SYSTEM, INCLUDE HOW EACH WILL | | | BE SECURED AT EACH STATION TO MEET THE REQUIREMENTS OF | | | FMC 502.20. | | | | | | 3) THE VENTILATION MUST SHOW THE REQUIRED OUTDOOR AIR | | | AND THE REQUIRED EXHAUST FOR THIS NAIL SALON. THE NAIL | | | SALON VENTILATION SHOULD BE CALCULATED FOR 28 PEOPLE. | | | 28 X 20 = 560; THE SPACE IS- 1105 X .12 = 133; 560 + | | | 133 = 693 CFM???S OF OUTDOOR AIR REQUIRED. PLEASE SHOW | | | THE REQUIRED EXHAUST FOR THE BATH ROOMS AND THE NAIL | | | STATIONS ??? NAIL STATIONS 663 CFM???S + BATH EXHAUST | | | 160 CFM = 823. WHERE WILL THE MAKEUP FOR THE EXHAUST | | | AIR COME FROM? FMC TABLE 403.3.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-14 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-14 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2023-02-14 15:15:15 | 2ND REVIEW FMC | | | PERMIT: 22121260 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON TABLE | | | 403.3.1.1 AND NOT THE ASHRAE 62.1. THE OCCUPANT COUNT | | | SHALL BE BASED FROM THE OCCUPANCY CLASSIFICATION AND | | | OCCUPANCY DENSITY OF TABLE 403.3.1.1. FMC 403.3.1.1 | | | | | | 2) THERE IS NO REFERENCE IN THE 2020 FMC FOR A PORTABLE | | | EXHAUST FAN, REMOVE THESE FROM THE DRAWING AND PROVIDE | | | AN EXHAUST SYSTEM FOR EACH NAIL STATION THAT COMPLIES | | | WITH FMC TABLE 403.3.1.1 FOOTNOTE H AND WITH FMC 502.20 | | | | | | 3) THE DRYER DUCT LENGTH, SIZE, MATERIAL AND | | | TERMINATION LOCATION MUST BE INCLUDED IN THIS NEW | | | TENANT DESIGN. A FLEXIBLE HOSE IS NOT AN OPTION IN THE | | | 2020 FMC SECTION 504 | | | | | | 4) THE CONDENSATE DRAINS SHALL NOT DRAIN TO STREET, | | | ALLEY OR OTHER AREAS SO AS TO CREATE A NUISANCE. FMC | | | 307.2.1 | | | | | | 5) THE CONDENSATE DRAINPIPE SHALL MEET THE MATERIAL | | | REQUIREMENTS OF FMC 307.2.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-06 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-06 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2023-01-06 08:41:01 | THE COVER SHEET HAS A MECHANICAL SHEET LISTED BUT NO | | | MECHANICAL SHEET WAS IN THE DRAWINGS. PROVIDE A | | | COMPLETE MECHANICAL DESIGN FOR THIS NAIL SALON. FBC | | | 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-08 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-08 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-15 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-15 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-06 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-06 |
Time |
06:31 |
Sent To |
|
|
| Notes |
| 2023-01-06 06:47:14 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. PAGE P-1 - 2020 FPC 912.1 - THE WATER CLOSET IS NOT | | | SHOWN AS BEING VENTED. THE LAVATORY TYPICALLY VENTS THE | | | WATER CLOSET FIXTURE DRAIN. ANY FIXTURES THAT ARE NOT | | | CONSIDERED BATHROOM GROUP FIXTURES CANNOT DISCHARGE | | | INTO THE LAV AND WATER CLOSET VENTING SYSTEM (WET | | | VENT). ALL OTHER FIXTURES (I.E. WASHER, HAND SINK, | | | SERVICE SINK) MUST | | | DISCHARGE DOWNSTREAM OF THE WET VENT SYSTEM. | | | | | | 2. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE DETAIL THE | | | WATER PIPING SYSTEM. WHEN DETAILING THE HOT WATER | | | SYSTEM, SHOW DETAILS THAT COMPLY WITH 2020 FPC 607.1.1 | | | - AND 2020 FPC 607.1.2. INCLUDE A WATER HEATER DETAIL | | | THAT INCLUDES WHERE THE T&P DISCHARGES, DRAIN PAN | | | TERMINATION POINT, AND DISTANCE TO FARTHEST FIXTURE | | | (NOT TO EXCEED 50 FEET WITHOUT A RECIRC LINE). | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-19 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-19 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-14 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-14 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-14 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-08 17:45:45 | MECHANICAL DIGITAL SIGNATURE APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-15 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-14 15:15:48 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-17 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|