Plan Review Details - Permit 22121194
Plan Review Stops For Permit 22121194
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-03 Cont ID  
Sent By aoliver Date 2023-02-03 Time 10:24 Rev Time 0.00
Received By aoliver Date 2023-02-01 Time 11:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-27 Cont ID  
Sent By lmarchan Date 2023-01-27 Time 11:13 Rev Time 0.00
Received By lmarchan Date 2023-01-25 Time 10:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-02-02 Cont ID  
Sent By ccole Date 2023-02-02 Time 07:46 Rev Time 0.00
Received By ccole Date 2023-02-02 Time 07:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-26 Cont ID  
Sent By ccole Date 2023-01-26 Time 08:02 Rev Time 0.00
Received By ccole Date 2023-01-26 Time 07:48 Sent To  
Notes
2023-01-26 08:03:231ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22121194
 1/26/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SUBMITTED DOUBLE CHECK VALVE ASSEMBLY IS NOT AN
 APPROVED BACKFLOW DEVICE FOR IRRIGATION SYSTEMS
 CONNECTED TO PUBLIC WATER SERVICE PER TABLE 1.1 WPB
 UTILITIES CROSS-CONNECTION MANUAL. THE MANUAL STATES A
 PVB SHALL BE INSTALLED IF BACKPRESSURE CANNOT DEVELOP
 IN THE SYSTEM, OR AN RPZ IF BACKPRESSURE COULD DEVELOP
 IN THE DOWNSTREAM PIPING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status P Date 2023-02-03 Cont ID  
Sent By aoliver Date 2023-02-03 Time 10:23 Rev Time 0.00
Received By aoliver Date 2023-02-03 Time 10:23 Sent To  
Notes
2023-02-03 10:24:15APPROVED BY DALTON GRIFFITHS -AO

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status F Date 2023-01-31 Cont ID  
Sent By lmarchan Date 2023-01-27 Time 11:13 Rev Time 0.00
Received By lmarchan Date 2023-01-27 Time 11:13 Sent To  
Notes
2023-01-31 09:19:34PER DGRIFFITHS - THIS IS AN APPROVED DEVICE FOR LOW
 HAZARD ONLY, SO IT CANNOT BE USED FOR IRRIGATION