| Plan Review Stops For Permit 22121052 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
2023-01-26 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
2023-01-26 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-27 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-27 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-22 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-22 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2023-06-22 15:34:30 | COMMERCIAL ADDITION/REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) REVISED DRAWING SP.1 - THE ACCESSIBLE PARKING SPACE | | | ACCESS AISLE NO LONGER SHOWS - PLEASE SHOW THE ALL OF | | | THE DIMENSIONS FOR THE ACCESSIBLE PARKING SPACE AND THE | | | ACCESS AISLE - FBC A 502 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-26 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-26 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2023-05-26 13:01:48 | COMMERCIAL ADDITION/REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING LSP1.0 SHOWS SEATING AT THE EXTERIOR BAR - | | | PLEASE SHOW THE OUTDOOR BAR ACCESSIBLE LOCATION, | | | COUNTER TOP HEIGHT, KNEE AND TOE CLEARANCES PER FBC A | | | 902.3 | | | | | | 2) DRAWING A1.0 HAS A SECTION REFERRING TO DRAWING A2.1 | | | - DRAWING A2.1 NEEDS TO BE SIGNED AND SEALED BY THE | | | DESIGNER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-04 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2023-05-04 11:24:00 | COMMERCIAL ADDITION/REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR BE | | | LISTED ON THE DRAWINGS BY THE PRODUCT APPROVAL NUMBER. | | | THE REVISED DRAWINGS DO NOT SHOW THE PRODUCT APPROVAL | | | NUMBERS FOR THE WINDOWS AND DOORS. FBC 107.3.4 | | | | | | 2) PLEASE SHOW THE SOUTH WALL OF THE BUILDING WHICH IS | | | 7 1/2 FEET FROM THE CENTER OF THE ALLY TO BE 1 HOUR | | | FIRE RATED PER FBC TABLE 602 (THE NOTE FOR THE WALL HAS | | | BEEN REMOVED ON THE REVISED DRAWINGS). | | | | | | 3) PLEASE SHOW THE OUTDOOR SERVING COUNTER TO BE | | | ACCESSIBLE PER FBC A 904.4 OR 902.3 (THE NOTE SAYING | | | STAFF ONLY HAS BEEN REMOVED ON THE REVISED DRAWINGS) | | | (THE FOOT REST IS BACK ON THE REVISED DRAWING). | | | | | | 4) PLEASE PROVIDE DETAILS OR PRODUCT APPROVALS SHOWING | | | ATTACHMENTS ETC. FOR THE EXTERIOR CORRUGATED METAL WALL | | | FINISH - FBC 1609.1 | | | | | | 5) DRAWINGS SP1.2, A2.1, NEED TO BE SIGNED AND SEALED | | | BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-15 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-15 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2023-03-15 10:05:04 | COMMERCIAL ADDITION/REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE HIGHER ROOF SCUPPERS NEED TO BE LEVEL WITH THE | | | ROOF - THE HIGHER ROOF OVER FLOW SCUPPERS NEED TO BE AS | | | SHOWN ON THE PLAN - BOTH ARE REQUIRED - | | | | | | 1503.4.2 SCUPPERS. | | | WHERE REQUIRED FOR ROOF DRAINAGE, A SCUPPER SHALL BE | | | PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR | | | PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY | | | THE SLOPE AND THE CONTRIBUTING AREA OF THE ROOF. THE | | | EXTERIOR FACING OR LINING OF A SCUPPER, IF METAL, SHALL | | | BE THE SAME AS FLASHING MATERIAL REQUIRED BY SECTIONS | | | 1503 THROUGH 1510 FOR THE PARTICULAR TYPE OF COVERING | | | SPECIFIED FOR THE BUILDING. FOR OTHER TYPE MATERIALS, | | | FOLLOW MANUFACTURER???S SPECIFICATIONS. | | | | | | 1503.4.2.1 OVERFLOW SCUPPERS. | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. | | | | | | 2) PLEASE SHOW THE STORM WATER DRAINAGE FLOW AWAY FROM | | | THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE | | | SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN - FBC | | | WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | | WATER RETAINING SWALES) | | | | | | 3) DRAWINGS CVR, G1.0, G1.1, G1.2, SP1.0, SP1.1, SP1.2, | | | LSP1.0, D1.0, D2.0, A1.0, A1.1, A1.2, A1.3, A1.4, A1.5, | | | A2.1, A2.0, A3.0, A3.1, A4.0, A5.0, A5.1, A6.0, A6.1, | | | A6.2, A7.0, S1.0, S2.1, S2.2, S4.4 NEED TO BE SIGNED | | | AND SEALED BY THE DESIGNER - SIGNED AND SEALED DRAWINGS | | | IN PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY | | | SIGNED TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2023-01-25 15:20:05 | COMMERCIAL ADDITION/REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND | | | ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD FBC WPB 107.3.4 | | | | | | 2) PLEASE SHOW THE SOUTH WALL OF THE BUILDING WHICH IS | | | 7 1/2 FEET FROM THE CENTER OF THE ALLY TO BE 1 HOUR | | | FIRE RATED PER FBC TABLE 602 | | | | | | 3) PLEASE SHOW THE WINDOW AREA ON THE SOUTH WALL OF THE | | | BUILDING THAT IS WITHIN THE WALL AREA THAT IS 7 1/2 | | | FEET FROM THE CENTER OF THE ALLY TO BE 10 PERCENT OR | | | LESS OF THAT TOTAL WALL SPACE FBC TABLE 705.8 | | | | | | 4) PLEASE SHOW THE WALLS SURROUNDING THE MOP SINK TO | | | COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | | | | 5) PLEASE PROVIDE ROOF TOP MECHANICAL SCREENING DETAILS | | | - FBC 1609.1 | | | | | | 6) PLEASE PROVIDE DETAILS OR PRODUCT APPROVALS SHOWING | | | ATTACHMENTS ETC. FOR THE EXTERIOR CORRIGATED METAL WALL | | | FINISH - FBC 1609.1 | | | | | | 7) DRAWING S1 SHOWS WIND DESIGN SPEED AS 169MPH - WIND | | | SPEED SHOULD BE 170MPH FOR A RISK CATEGORY II BUILDING | | | PER FBC WPB SECTION 120 | | | | | | 8) PLEASE SHOW THE ROOF TOP OVER FLOW SCUPPERS FOR THE | | | HIGHER ROOF - FBC 1503.4.2.1 OVERFLOW SCUPPERS. | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | | SCUPPERS. | | | | | | 9) DRAWING A2.0 DETAIL 2 - PLEASE SHOW THE SHOWER GRAB | | | BAR LOCATIONS PER FBC A 608.3.2 | | | | | | 10) ACCESSIBLE SHOWER - PLEASE PROVIDE A SHOWER SEAT | | | DETAIL PER FBC A 610 | | | | | | 11) PLEASE SHOW THE OUTDOOR SERVING COUNTER TO BE | | | ACCESSIBLE PER FBC A 904.4 OR 902.3 | | | | | | 12) PLEASE SHOW THE STORM WATER DRAINAGE FLOW AWAY FROM | | | THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE | | | SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN - FBC | | | WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | | WATER RETAINING SWALES) | | | | | | 13) A SEPARATE PERMIT IS REQUIRED FOR - SITE WALL, | | | PARKING LOT, FENCES | | | | | | 14) SIDING DETAILS, WINDOW,DOOR AND ROOFING SYSTEM | | | PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING | | | ITEMS TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | FBC WPB 107.3.4.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-25 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-24 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-03-17 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-03-17 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2023-03-17 12:36:18 | SITE PLAN STILL UNDER REVIEW. | | | | | | THANKS, | | | | | | LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT (561) 494-1085 | | | [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-01-03 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2023-01-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-03 08:52:47 | A FORMAL ENGINEERING SUBMITTAL IS REQUIRED FOR NEW | | | WATER CONNECTIONS WITHIN THE RIGHT OF WAY. | | | | | | THANKS, | | | RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES | | | DEPT., 561-494-1098, FAX: 561-494-1116 [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-22 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-26 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-01-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-12-28 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2023-01-05 12:55:44 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | CAPT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-05 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-05 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-13 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-01-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-11 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2023-01-09 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2023-01-11 09:28:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22121052 2025 N DIXIE HWY | | | | | | GAS COMMENTS: DENIED | | | | | | 1. STEEL PIPING BETWEEN METER/REGULATOR AND THE WATER | | | HEATER APPEARS TO TRAVEL UNDERGROUND. PER FBC FG | | | 404.11, PROVIDE METHOD TO PROTECT UNDERGROUND PIPING | | | FROM CORROSION COMPLYING WITH FBC FG 404.11.1, | | | 404.11.2. IF PIPING IS TO BE ROUTED ABOVE GROUND, | | | PLEASE CLARIFY AND INDICATE ON THE PLAN. | | | | | | 2. PLEASE NOTE ON THE PLAN THAT A REGULATOR REDUCING | | | PRESSURE FROM 2 PSI TO THE PRESSURE REQUIREMENTS OF THE | | | WATER HEATER SHALL BE PROVIDED. FBC FG 410.1 | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-28 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-26 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-06-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-06-23 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-06-20 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-05 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-25 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-12 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-03 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-21 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-03-10 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-01-26 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-12-27 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-07-03 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2023-07-03 07:52:33 | EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2023-01-25 15:20:54 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-09 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-09 |
Time |
06:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-15 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-15 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2023-03-15 13:09:54 | 2ND REVIEW FMC | | | PERMIT: 22121052 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | | | | 1) PROVIDE A DETAIL FOR THE LAUNDRY, DRYER DUCT. | | | MATERIAL, SIZE, LENGTH AND TERMINATION LOCATION. FMC | | | 504 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-17 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-17 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2023-01-17 13:43:40 | 1ST REVIEW FMC | | | PERMIT: 22121052!0 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M6.1: THE RTU-2 AND RTU-3 DO NOT SHOW ANY | | | OUTDOOR AIR IN THE EQUIPMENT SCHEDULE. PLEASE SHOW THE | | | REQUIRED OUTDOOR AIR FOR EACH RTU AND PROVIDE THE | | | OUTDOOR AIR CALCULATION FOR EACH BASED ON THE OCCUPANCY | | | CLASSIFICATION. FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 2) SHEET M2.1: IT APPEARS THE RTU-3 IS RECEIVING RETURN | | | AIR FROM A STORAGE ROOM BY THE OFFICE. IF THIS IS A | | | RETURN PLEASE REMOVE THIS RETURN DUCT FROM THE CLOSET. | | | FMC 601.5 7 | | | | | | 3) SHOW THAT EACH RTU WILL MEET THE SMOKE DETECTOR | | | REQUIREMENTS OF FMC 606.2.1 AND 606.2.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-22 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-22 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-05 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-05 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-13 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2023-03-13 16:30:03 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | 2. THIS COMMENT NOT ADDRESSED. THIS COMMENT IS FOR HOT | | | WATER DELIVERY. YOUR RESPONSE ADDRESSES TEMPERED WATER. | | | THE WATER HEATER DETAIL SHOULD SHOW A MIXING VALVE. | | | PER FBC 607.1.1, 613.1, PROVIDE A TEMPERATURE-ACTUATED | | | MIXING VALVE, INSTALLED TO REDUCE WATER TEMPERATURES TO | | | DEFINED LIMITS, SHALL COMPLY WITH ASSE 1017. SUCH VALVE | | | SHALL BE INSTALLED AT THE HOT WATER SOURCE. THIS | | | PROTECTION LEVEL IS IN ADDITION TO THE REQUIREMENTS | | | NEEDED FOR PUBLIC HAND WASHING DICTATED BY FBC PL | | | 419.5, 607.1.2. | | | | | | 3. DONE | | | | | | 4. DONE | | | | | | 5. 2020 FPC 905.4 - THE VENTS FOR THE SHOWERS ARE NOT | | | ALLOWED TO BE HORIZONTAL WHILE DRY. EACH VENT MUST | | | REMAIN VERTICAL UNTIL 6" ABOVE THE FIXTURE(S) SERVED. | | | | | | 6. 2020 FPC 918.8 - AN AIR ADMITTANCE VALVE CANNOT BE | | | USED TO VENT THE GREASE TRAP. THIS CREATES AN "AIR | | | BOUND" TRAP. A VENT TO THE OPEN AIR IS REQUIRED. | | | | | | 7. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE | | | AT THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | | EMAILING A COMPLETED PERMIT APPLICATION TO | | | [email protected]. AFTER YOU HAVE THE PERMIT(S) | | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | | LETTER AND I WILL COMPLY THIS COMMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-09 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2023-01-04 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2023-01-09 16:24:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22121052 2025 N DIXIE HWY | | | | | | 1ST REVIEW | | | | | | A SEPARATE PERMIT FOR GREASE INTERCEPTOR IS REQUIRED TO | | | BE SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT | | | (AS APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" | | | (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR | | | SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO | | | [email protected] . YOU WILL RECEIVE INSTRUCTIONS | | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS | | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | | AND UPLOAD PLANS AT THE SAME TIME. A SEPARATE PERMIT IS | | | REQUIRED HOWEVER A REVIEW OF THE SYSTEM UNDER THE MAIN | | | PERMIT IS ALSO REQUIRED. | | | AFTER YOU HAVE THE PERMIT(S) GENERATED, PLEASE NOTIFY | | | ME AT [email protected] AND CC SAMANTHA HILL, CHIEF PLANS | | | EXAMINER AT [email protected] AND RYAN BROWN, CHIEF | | | PLUMBING INSPECTOR AT [email protected] VIA EMAIL WITH | | | THE PERMIT NUMBER(S). | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | | PROCESS (SEE FBC PL 404.1) BUT IS TYPICALLY ADDRESSED | | | ON THE ARCHITECTURAL PLANS. ANY COMMENTS CONCERNING | | | THESE REQUIREMENTS MUST BE SATISFACTORILY ADDRESSED | | | PRIOR TO A PLUMBING REVIEW APPROVAL. | | | ***A) PLAN G1.2: PROVIDE ADDITIONAL DETAILS (PLAN AND | | | ELEVATION) FOR STANDARD ROLL IN SHOWER WITH SEAT | | | SHOWING DIMENSIONS, LOCATIONS AND HEIGHTS OF GRAB BARS, | | | CONTROL VALVE, FAUCETS, SHOWER SPRAY UNIT. COMPLY WITH | | | FBC ACC 608.2.2, 608.3.2, 608.5.2, 608.6, 609.4, 610.3, | | | 610.3.1. | | | ***B) PROVIDE DETAIL FOR ACCESSIBLE WASHER AND DRYER | | | SHOWING COMPLIANCE WITH FBC ACC 611.3 | | | ***C) PROVIDE CLEAR FLOOR SPACE FOR ACCESSIBLE WASHER | | | AND DRYER SHOWING COMPLIANCE WITH FBC ACC 611.2, 305. | | | | | | 2. PER FBC 607.1.1, 613.1, PROVIDE A | | | TEMPERATURE-ACTUATED MIXING VALVE, INSTALLED TO REDUCE | | | WATER TEMPERATURES TO DEFINED LIMITS, SHALL COMPLY WITH | | | ASSE 1017. SUCH VALVE SHALL BE INSTALLED AT THE HOT | | | WATER SOURCE. THIS PROTECTION LEVEL IS IN ADDITION TO | | | THE REQUIREMENTS NEEDED FOR PUBLIC HAND WASHING | | | DICTATED BY FBC PL 419.5, 607.1.2. | | | | | | 3. IT APPEARS THE HOT WATER PIPING FROM THE HOT WATER | | | SOURCE TO THE PUBLIC LAVATORIES EXCEEDS 2 FEET. REFER | | | TO TABLE C404.5.1 FBC EC- THE 1/2 -INCH HOT WATER PIPE | | | TO THE LAVATORY SHALL NOT EXCEED 2 FEET FROM THE HOT | | | WATER SOURCE. | | | | | | 4. RE: P-2.1, P-5.1; CIRCUIT VENTED BRANCH FOR WATER | | | CLOSETS | | | ***A) THE CIRCUIT VENT CONNECTION SHALL BE LOCATED | | | BETWEEN THE TWO MOST UPSTREAM FIXTURE DRAINS (WATER | | | CLOSETS). FBC PL 914.2 | | | ***B) FIXTURES OTHER THAN THE CIRCUIT VENTED FIXTURES | | | DISCHARGING TO THE CIRCUIT VENTED BRANCH SHALL BE | | | INDIVIDUALLY OR COMMON VENTED. FBC PL 914.5 | | | | | | 5. RE: P-2.1, P-5.1; SHOWER DRAINS | | | ***A) BRANCH SHALL BE SIZED 3 INCH TO THE CONNECTION | | | WITH MOST UPSTREAM SHOWER FIXTURE DRAIN. FBC PL TABLE | | | 915.2.2 | | | ***B) VENT SHALL CONNECT ABOVE THE CENTERLINE OF THE | | | DRAIN OF THE HORIZONTAL DRAIN AND SHALL RISE VERTICALLY | | | TO A POINT NOT LESS THAN 6 INCHES ABOVE THE FLOOD LEVEL | | | RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED | | | PER FBC PL 905.3 AND 905.4. O BE CLEAR, THERE SHALL BE | | | NO HORIZONTAL TRAVEL BETWEEN THE BRANCH AND THE | | | VERTICAL PORTION OF THE VENT. | | | ***C) PER FBC PL 915.2.5, SHOWER FIXTURE DRAINS SHALL | | | NOT EXCEED THE MAXIMUM ALLOWABLE DISTANCE FROM TRAP TO | | | VENT AS ALLOWED IN FBC PL TABLE 909.1 UNLESS SIZED THE | | | SAME AS THE BRANCH. | | | | | | 6. TRAPPED FLOOR SINK DISCHARGING TO GREASE INTERCEPTOR | | | SHALL BE VENTED. FBC PL 909.1 | | | PLEASE NOTE, A SEPARATE PERMIT FOR THE GREASE | | | INTERCEPTOR IS REQUIRED. | | | | | | 7. PLEASE PROVIDE SIZES AND MINIMUM SLOPES OF PRIMARY | | | AND SECONDARY STORM DRAINS. FBC PL 1106.2, TABLE 1106.2 | | | | | | 8. PLEASE PROVIDE OVERFLOW SCUPPERS FOR PADEL COURT | | | ROOF. FBC PL 1108.1 | | | | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-15 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-15 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2023-03-15 10:07:56 | ROOFING SYSTEM TO BE DEFERRED |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-25 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2023-01-25 15:21:26 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-27 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-27 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-22 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-22 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-26 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-26 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2023-05-26 13:02:19 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A2.1 NEEDS TO BE SIGNED AND SEALED BY THE | | | DESIGNER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-04 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2023-05-04 11:25:04 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS SP1.2, A2.1, NEED TO BE SIGNED AND SEALED | | | BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-15 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-15 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2023-03-15 10:30:32 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS CVR, G1.0, G1.1, G1.2, SP1.0, SP1.1, SP1.2, | | | LSP1.0, D1.0, D2.0, A1.0, A1.1, A1.2, A1.3, A1.4, A1.5, | | | A2.1, A2.0, A3.0, A3.1, A4.0, A5.0, A5.1, A6.0, A6.1, | | | A6.2, A7.0, S1.0, S2.1, S2.2, S4.4 DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-24 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-01-24 13:24:08 | ALL PLANS PASSED SIGNATURE REVIEW. MP | | 2023-01-17 13:44:30 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-06-28 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-06-28 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2023-06-28 09:13:40 | 6/28/23 ??? PASSED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [SATISFIED] | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). | | | [SATISFIED] | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; [WITHDRAWN] | | | B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN] | | | C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN] | | | D. EXISTING USE(S); [SATISFIED] | | | E. PROPOSED USE(S); [SATISFIED] | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | [SATISFIED] | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; [WITHDRAWN] | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED] | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED] | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [SATISFIED] | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [SATISFIED] | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED] | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [SATISFIED] | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED] | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | Q. EXISTING PARCEL LINES; [SATISFIED] | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | [WITHDRAWN] | | | S. EXISTING BUILDING HEIGHT; [WITHDRAWN] | | | T. PROPOSED BUILDING HEIGHT; [WITHDRAWN] | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; | | | [WITHDRAWN] | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | [WITHDRAWN] | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; [WITHDRAWN] | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | [WITHDRAWN] | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. [WITHDRAWN] | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | [WITHDRAWN] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED: | | | 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1., | | | PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE | | | CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418 | | | ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON | | | THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [WITHDRAWN] | | | 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY | | | OF TITLE FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE | | | PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE | | | CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010 | | | ON SHEET NUMBER SP1.0. [SATISFIED] | | | 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE | | | FOOTAGE CALCULATION FOR PARCEL NUMBER | | | 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1, | | | AND SP1.2. [SATISFIED] | | | 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT | | | DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND | | | SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK | | | DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL | | | LINE. [SATISFIED] | | | 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS | | | OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING | | | LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON | | | THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE | | | PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE | | | SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE | | | WALL NOTES. [SATISFIED] | | | 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY | | | 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING | | | BUILDING IS NOT A PART OF THE PRIVATE PROPERTY, | | | THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED | | | PLANS. [SATISFIED] | | | 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT | | | HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS | | | HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE, | | | PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS. | | | [SATISFIED] | | | 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO | | | LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET | | | FROM THE PERMIT APPLICATION FILE. [SATISFIED] | | | 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE | | | MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE | | | OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC. | | | [SATISFIED] | | | 19. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.J., IT | | | HAS BEEN IDENTIFIED THAT THE EXISTING AND PROPOSED OPEN | | | SPACE CALCULATIONS INDICATED ARE THE SAME, WHICH DOES | | | NOT REFLECT THE PROPOSAL. THEREFORE, PLEASE UPDATE | | | ACCORDINGLY. [SATISFIED] | | | 20. IN REFERENCE TO PREVIOUS REVIEW COMMENTS 3.M. AND | | | 3.O., DISCREPANCIES HAVE BEEN IDENTIFIED FOR THE | | | PROPOSED BUILDING LOT COVERAGE CALCULATIONS INDICATED. | | | THEREFORE, PLEASE UPDATE ACCORDINGLY. [NOT SATISFIED]. | | | | | | PROVISO: | | | PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY: | | | 1. PROOF OF AN APPROVED AND RECORDED UNITY OF TITLE OF | | | THE TWO PARCELS MUST BE PROVIDED. | | | 2. APPROVAL OF INFORMAL SITE PLAN REVIEW 23-02 | | | (Z23040019) MUST BE OBTAINED. | | | 3. SEPARATE PERMITS FOR THE OVERALL SITE INCLUDING, BUT | | | NOT LIMITED TO, THE LANDSCAPE, SIGNAGE, PARKING, PADEL | | | COURTS, WALL/GATES, AND EXTERIOR LIGHTING MUST BE | | | OBTAINED. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2023-06-23 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-06-23 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-06-23 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2023-06-23 11:42:20 | 6/23/23 ??? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [SATISFIED] | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). | | | [SATISFIED] | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; [WITHDRAWN] | | | B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN] | | | C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN] | | | D. EXISTING USE(S); [SATISFIED] | | | E. PROPOSED USE(S); [SATISFIED] | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | [SATISFIED] | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; [WITHDRAWN] | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED] | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED] | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED] | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [SATISFIED] | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED] | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [SATISFIED] | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED] | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | Q. EXISTING PARCEL LINES; [SATISFIED] | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | [WITHDRAWN] | | | S. EXISTING BUILDING HEIGHT; [WITHDRAWN] | | | T. PROPOSED BUILDING HEIGHT; [WITHDRAWN] | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; | | | [WITHDRAWN] | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | [WITHDRAWN] | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; [WITHDRAWN] | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | [WITHDRAWN] | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. [WITHDRAWN] | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | [WITHDRAWN] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED: | | | 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1., | | | PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE | | | CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418 | | | ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON | | | THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [WITHDRAWN] | | | 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY | | | OF TITLE FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE | | | PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE | | | CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010 | | | ON SHEET NUMBER SP1.0. [SATISFIED] | | | 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE | | | FOOTAGE CALCULATION FOR PARCEL NUMBER | | | 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1, | | | AND SP1.2. [SATISFIED] | | | 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT | | | DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND | | | SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK | | | DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL | | | LINE. [SATISFIED] | | | 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS | | | OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING | | | LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON | | | THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE | | | PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE | | | SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE | | | WALL NOTES. [SATISFIED] | | | 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY | | | 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING | | | BUILDING IS NOT A PART OF THE PRIVATE PROPERTY, | | | THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED | | | PLANS. [SATISFIED] | | | 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT | | | HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS | | | HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE, | | | PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS. | | | [SATISFIED] | | | 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO | | | LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET | | | FROM THE PERMIT APPLICATION FILE. [SATISFIED] | | | 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE | | | MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE | | | OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC. | | | [SATISFIED] | | | 19. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.J., IT | | | HAS BEEN IDENTIFIED THAT THE EXISTING AND PROPOSED OPEN | | | SPACE CALCULATIONS INDICATED ARE THE SAME, WHICH DOES | | | NOT REFLECT THE PROPOSAL. THEREFORE, PLEASE UPDATE | | | ACCORDINGLY. | | | 20. IN REFERENCE TO PREVIOUS REVIEW COMMENTS 3.M. AND | | | 3.O., DISCREPANCIES HAVE BEEN IDENTIFIED FOR THE | | | PROPOSED BUILDING LOT COVERAGE CALCULATIONS INDICATED. | | | THEREFORE, PLEASE UPDATE ACCORDINGLY. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-06-05 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-06-05 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2023-06-05 11:07:09 | 6/5/23 ??? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [SATISFIED] | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT | | | SATISFIED] | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; [WITHDRAWN] | | | B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN] | | | C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN] | | | D. EXISTING USE(S); [SATISFIED] | | | E. PROPOSED USE(S); [SATISFIED] | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | [NOT SATISFIED] | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; [WITHDRAWN] | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | Q. EXISTING PARCEL LINES; [SATISFIED] | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | [WITHDRAWN] | | | S. EXISTING BUILDING HEIGHT; [WITHDRAWN] | | | T. PROPOSED BUILDING HEIGHT; [WITHDRAWN] | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; | | | [WITHDRAWN] | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | [WITHDRAWN] | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; [WITHDRAWN] | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | [WITHDRAWN] | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. [WITHDRAWN] | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | [WITHDRAWN] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED] | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED: | | | 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1., | | | PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE | | | CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418 | | | ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON | | | THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [WITHDRAWN] | | | 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY | | | OF TITLE FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE | | | PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE | | | CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010 | | | ON SHEET NUMBER SP1.0. [SATISFIED] | | | 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE | | | FOOTAGE CALCULATION FOR PARCEL NUMBER | | | 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1, | | | AND SP1.2. [NOT SATISFIED] | | | 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT | | | DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND | | | SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK | | | DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL | | | LINE. [SATISFIED] | | | 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS | | | OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING | | | LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON | | | THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE | | | PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE | | | SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE | | | WALL NOTES. [PARTIALLY SATISFIED] | | | 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY | | | 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING | | | BUILDING IS NOT A PART OF THE PRIVATE PROPERTY, | | | THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED | | | PLANS. | | | 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT | | | HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS | | | HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE, | | | PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS. | | | 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO | | | LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET | | | FROM THE PERMIT APPLICATION FILE. | | | 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE | | | MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE | | | OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-05-11 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-05-11 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2023-05-11 17:05:34 | 5/11/23 ??? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [SATISFIED] | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT | | | SATISFIED] | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; [WITHDRAWN] | | | B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN] | | | C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN] | | | D. EXISTING USE(S); [SATISFIED] | | | E. PROPOSED USE(S); [NOT SATISFIED] | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | [SATISFIED] | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; [WITHDRAWN] | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | Q. EXISTING PARCEL LINES; [PARTIALLY SATISFIED] | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | [WITHDRAWN] | | | S. EXISTING BUILDING HEIGHT; [WITHDRAWN] | | | T. PROPOSED BUILDING HEIGHT; [WITHDRAWN] | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; | | | [WITHDRAWN] | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | [WITHDRAWN] | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; [WITHDRAWN] | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | [WITHDRAWN] | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. [WITHDRAWN] | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | [WITHDRAWN] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [NOT | | | SATISFIED] | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [NOT | | | SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED: | | | 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1., | | | PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE | | | CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418 | | | ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON | | | THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [WITHDRAWN] | | | 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY | | | OF TITLE FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE | | | PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | [WITHDRAWN] | | | 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE | | | CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010 | | | ON SHEET NUMBER SP1.0. | | | 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE | | | FOOTAGE CALCULATION FOR PARCEL NUMBER | | | 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1, | | | AND SP1.2. | | | 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER | | | 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT | | | DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND | | | SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK | | | DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL | | | LINE. | | | 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS | | | OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING | | | LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON | | | THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE | | | PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE | | | SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE | | | WALL NOTES. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-03-21 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-03-21 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2023-03-21 09:46:24 | 3/21/23 ??? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). [SATISFIED] | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT | | | SATISFIED] | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; [PARTIALLY SATISFIED] | | | B. CURRENT ZONING DESIGNATIONS; [PARTIALLY SATISFIED] | | | C. FUTURE LAND USE CLASSIFICATIONS; [NOT SATISFIED] | | | D. EXISTING USE(S); [SATISFIED] | | | E. PROPOSED USE(S); [NOT SATISFIED] | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | [SATISFIED] | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; [NOT SATISFIED] | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED] | | | Q. EXISTING PARCEL LINES; [PARTIALLY SATISFIED] | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | [NOT SATISFIED] | | | S. EXISTING BUILDING HEIGHT; [NOT SATISFIED] | | | T. PROPOSED BUILDING HEIGHT; [NOT SATISFIED] | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; [NOT | | | SATISFIED] | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | [NOT SATISFIED] | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; [NOT SATISFIED] | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | [NOT SATISFIED] | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. [NOT SATISFIED] | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | [WITHDRAWN] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [NOT | | | SATISFIED] | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [NOT | | | SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED: | | | 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1., | | | PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE | | | CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418 | | | ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON | | | THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). | | | 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY | | | OF TITLE FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT | | | APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT | | | PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE | | | PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS | | | 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
KDefranc |
Date |
2023-01-06 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-01-06 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2023-01-06 14:00:29 | 1/6/23 ??? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE | | | OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE | | | ADJACENT PARCEL TO THE WEST (PARCEL NUMBER | | | 74-43-43-16-15-001-0070). | | | 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE | | | PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO | | | THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). | | | 3. PLEASE SUBMIT REVISED SITE PLANS | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL NUMBERS; | | | B. CURRENT ZONING DESIGNATIONS; | | | C. FUTURE LAND USE CLASSIFICATIONS; | | | D. EXISTING USE(S); | | | E. PROPOSED USE(S); | | | F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION; | | | G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO | | | PARCELS; | | | H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; | | | I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE | | | FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; | | | J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND | | | PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE | | | CALCULATION IN RELATION TO PARCEL NUMBER | | | 74-43-43-16-15-001-0010; | | | P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO | | | PARCEL NUMBER 74-43-43-16-15-001-0010; | | | Q. EXISTING PARCEL LINES; | | | R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES; | | | S. EXISTING BUILDING HEIGHT; | | | T. PROPOSED BUILDING HEIGHT; | | | U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; | | | V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS; | | | 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN | | | IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING: | | | A. EXISTING PARCEL LINES; | | | B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND | | | C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO | | | ALL PARCEL LINES. | | | 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE | | | PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT | | | ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND | | | DEVELOPMENT REGULATIONS SUBSECTION 94-306(A). | | | THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY. | | | | | | ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A | | | LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. | | | 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER ??? PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|