Plan Review Details - Permit 22121052
Plan Review Stops For Permit 22121052
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2023-01-26 Cont ID  
Sent By swelter Date 2023-01-26 Time 15:14 Rev Time 0.00
Received By swelter Date 2023-01-26 Time 15:14 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-01-25 Cont ID  
Sent By rmcphers Date 2023-01-25 Time 14:41 Rev Time 0.00
Received By rmcphers Date 2023-01-25 Time 14:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2023-06-27 Cont ID  
Sent By rmcphers Date 2023-06-27 Time 09:11 Rev Time 0.00
Received By rmcphers Date 2023-06-27 Time 09:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-06-22 Cont ID  
Sent By rmcphers Date 2023-06-22 Time 15:31 Rev Time 0.00
Received By rmcphers Date 2023-06-22 Time 15:31 Sent To  
Notes
2023-06-22 15:34:30COMMERCIAL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) REVISED DRAWING SP.1 - THE ACCESSIBLE PARKING SPACE
 ACCESS AISLE NO LONGER SHOWS - PLEASE SHOW THE ALL OF
 THE DIMENSIONS FOR THE ACCESSIBLE PARKING SPACE AND THE
 ACCESS AISLE - FBC A 502
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-05-26 Cont ID  
Sent By rmcphers Date 2023-05-26 Time 12:45 Rev Time 0.00
Received By rmcphers Date 2023-05-26 Time 12:45 Sent To  
Notes
2023-05-26 13:01:48COMMERCIAL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING LSP1.0 SHOWS SEATING AT THE EXTERIOR BAR -
 PLEASE SHOW THE OUTDOOR BAR ACCESSIBLE LOCATION,
 COUNTER TOP HEIGHT, KNEE AND TOE CLEARANCES PER FBC A
 902.3
  
 2) DRAWING A1.0 HAS A SECTION REFERRING TO DRAWING A2.1
 - DRAWING A2.1 NEEDS TO BE SIGNED AND SEALED BY THE
 DESIGNER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-05-04 Cont ID  
Sent By rmcphers Date 2023-05-04 Time 11:25 Rev Time 0.00
Received By rmcphers Date 2023-05-04 Time 11:09 Sent To  
Notes
2023-05-04 11:24:00COMMERCIAL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD OR BE
 LISTED ON THE DRAWINGS BY THE PRODUCT APPROVAL NUMBER.
 THE REVISED DRAWINGS DO NOT SHOW THE PRODUCT APPROVAL
 NUMBERS FOR THE WINDOWS AND DOORS. FBC 107.3.4
  
 2) PLEASE SHOW THE SOUTH WALL OF THE BUILDING WHICH IS
 7 1/2 FEET FROM THE CENTER OF THE ALLY TO BE 1 HOUR
 FIRE RATED PER FBC TABLE 602 (THE NOTE FOR THE WALL HAS
 BEEN REMOVED ON THE REVISED DRAWINGS).
  
 3) PLEASE SHOW THE OUTDOOR SERVING COUNTER TO BE
 ACCESSIBLE PER FBC A 904.4 OR 902.3 (THE NOTE SAYING
 STAFF ONLY HAS BEEN REMOVED ON THE REVISED DRAWINGS)
 (THE FOOT REST IS BACK ON THE REVISED DRAWING).
  
 4) PLEASE PROVIDE DETAILS OR PRODUCT APPROVALS SHOWING
 ATTACHMENTS ETC. FOR THE EXTERIOR CORRUGATED METAL WALL
 FINISH - FBC 1609.1
  
 5) DRAWINGS SP1.2, A2.1, NEED TO BE SIGNED AND SEALED
 BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-15 Cont ID  
Sent By rmcphers Date 2023-03-15 Time 10:05 Rev Time 0.00
Received By rmcphers Date 2023-03-15 Time 09:44 Sent To  
Notes
2023-03-15 10:05:04COMMERCIAL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE HIGHER ROOF SCUPPERS NEED TO BE LEVEL WITH THE
 ROOF - THE HIGHER ROOF OVER FLOW SCUPPERS NEED TO BE AS
 SHOWN ON THE PLAN - BOTH ARE REQUIRED -
  
 1503.4.2 SCUPPERS.
 WHERE REQUIRED FOR ROOF DRAINAGE, A SCUPPER SHALL BE
 PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR
 PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY
 THE SLOPE AND THE CONTRIBUTING AREA OF THE ROOF. THE
 EXTERIOR FACING OR LINING OF A SCUPPER, IF METAL, SHALL
 BE THE SAME AS FLASHING MATERIAL REQUIRED BY SECTIONS
 1503 THROUGH 1510 FOR THE PARTICULAR TYPE OF COVERING
 SPECIFIED FOR THE BUILDING. FOR OTHER TYPE MATERIALS,
 FOLLOW MANUFACTURER???S SPECIFICATIONS.
  
 1503.4.2.1 OVERFLOW SCUPPERS.
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT
 PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR
 PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4
 INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND
 SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED
 VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET
 SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING.
  
 2) PLEASE SHOW THE STORM WATER DRAINAGE FLOW AWAY FROM
 THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE
 SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN - FBC
 WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  
 3) DRAWINGS CVR, G1.0, G1.1, G1.2, SP1.0, SP1.1, SP1.2,
 LSP1.0, D1.0, D2.0, A1.0, A1.1, A1.2, A1.3, A1.4, A1.5,
 A2.1, A2.0, A3.0, A3.1, A4.0, A5.0, A5.1, A6.0, A6.1,
 A6.2, A7.0, S1.0, S2.1, S2.2, S4.4 NEED TO BE SIGNED
 AND SEALED BY THE DESIGNER - SIGNED AND SEALED DRAWINGS
 IN PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY
 SIGNED TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-25 Cont ID  
Sent By rmcphers Date 2023-01-25 Time 15:20 Rev Time 0.00
Received By rmcphers Date 2023-01-25 Time 11:00 Sent To  
Notes
2023-01-25 15:20:05COMMERCIAL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND
 ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD FBC WPB 107.3.4
  
 2) PLEASE SHOW THE SOUTH WALL OF THE BUILDING WHICH IS
 7 1/2 FEET FROM THE CENTER OF THE ALLY TO BE 1 HOUR
 FIRE RATED PER FBC TABLE 602
  
 3) PLEASE SHOW THE WINDOW AREA ON THE SOUTH WALL OF THE
 BUILDING THAT IS WITHIN THE WALL AREA THAT IS 7 1/2
 FEET FROM THE CENTER OF THE ALLY TO BE 10 PERCENT OR
 LESS OF THAT TOTAL WALL SPACE FBC TABLE 705.8
  
 4) PLEASE SHOW THE WALLS SURROUNDING THE MOP SINK TO
 COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 5) PLEASE PROVIDE ROOF TOP MECHANICAL SCREENING DETAILS
 - FBC 1609.1
  
 6) PLEASE PROVIDE DETAILS OR PRODUCT APPROVALS SHOWING
 ATTACHMENTS ETC. FOR THE EXTERIOR CORRIGATED METAL WALL
 FINISH - FBC 1609.1
  
 7) DRAWING S1 SHOWS WIND DESIGN SPEED AS 169MPH - WIND
 SPEED SHOULD BE 170MPH FOR A RISK CATEGORY II BUILDING
 PER FBC WPB SECTION 120
  
 8) PLEASE SHOW THE ROOF TOP OVER FLOW SCUPPERS FOR THE
 HIGHER ROOF - FBC 1503.4.2.1 OVERFLOW SCUPPERS.
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT
 PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR
 PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4
 INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND
 SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED
 VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET
 SCUPPERS.
  
 9) DRAWING A2.0 DETAIL 2 - PLEASE SHOW THE SHOWER GRAB
 BAR LOCATIONS PER FBC A 608.3.2
  
 10) ACCESSIBLE SHOWER - PLEASE PROVIDE A SHOWER SEAT
 DETAIL PER FBC A 610
  
 11) PLEASE SHOW THE OUTDOOR SERVING COUNTER TO BE
 ACCESSIBLE PER FBC A 904.4 OR 902.3
  
 12) PLEASE SHOW THE STORM WATER DRAINAGE FLOW AWAY FROM
 THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE
 SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN - FBC
 WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  
 13) A SEPARATE PERMIT IS REQUIRED FOR - SITE WALL,
 PARKING LOT, FENCES
  
 14) SIDING DETAILS, WINDOW,DOOR AND ROOFING SYSTEM
 PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING
 ITEMS TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS -
 FBC WPB 107.3.4.1

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-01-25 Cont ID  
Sent By mpeterso Date 2023-01-25 Time 09:04 Rev Time 0.00
Received By mpeterso Date 2023-01-24 Time 13:07 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2023-03-17 Cont ID  
Sent By lquinone Date 2023-03-17 Time 12:35 Rev Time 0.00
Received By lquinone Date 2023-03-17 Time 12:35 Sent To  
Notes
2023-03-17 12:36:18SITE PLAN STILL UNDER REVIEW.
  
 THANKS,
  
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By rrossano Date 2023-01-03 Time   Rev Time  
Received By rrossano Date 2023-01-03 Time   Sent To  
Notes
2023-01-03 08:52:47A FORMAL ENGINEERING SUBMITTAL IS REQUIRED FOR NEW
 WATER CONNECTIONS WITHIN THE RIGHT OF WAY.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES
 DEPT., 561-494-1098, FAX: 561-494-1116 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2023-06-22 Cont ID  
Sent By pleduc Date 2023-06-22 Time   Rev Time 0.00
Received By pleduc Date 2023-06-22 Time 16:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-05-26 Cont ID  
Sent By pleduc Date 2023-05-26 Time   Rev Time 0.00
Received By pleduc Date 2023-05-26 Time 10:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-04 Cont ID  
Sent By pleduc Date 2023-05-04 Time   Rev Time 0.00
Received By pleduc Date 2023-05-04 Time 10:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-01-05 Cont ID  
Sent By   Date 2023-01-05 Time   Rev Time 0.00
Received By bdolan Date 2022-12-28 Time 12:55 Sent To  
Notes
2023-01-05 12:55:44PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 CAPT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-05-05 Cont ID  
Sent By rwbrown Date 2023-05-05 Time 08:01 Rev Time 0.00
Received By rwbrown Date 2023-05-05 Time 08:01 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-03-13 Cont ID  
Sent By rwbrown Date 2023-03-13 Time 16:30 Rev Time 0.00
Received By rwbrown Date 2023-03-13 Time 16:30 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-01-11 Cont ID  
Sent By jesmith Date 2023-01-11 Time 09:28 Rev Time 0.00
Received By jesmith Date 2023-01-09 Time 16:30 Sent To  
Notes
2023-01-11 09:28:54CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22121052 2025 N DIXIE HWY
  
 GAS COMMENTS: DENIED
  
 1. STEEL PIPING BETWEEN METER/REGULATOR AND THE WATER
 HEATER APPEARS TO TRAVEL UNDERGROUND. PER FBC FG
 404.11, PROVIDE METHOD TO PROTECT UNDERGROUND PIPING
 FROM CORROSION COMPLYING WITH FBC FG 404.11.1,
 404.11.2. IF PIPING IS TO BE ROUTED ABOVE GROUND,
 PLEASE CLARIFY AND INDICATE ON THE PLAN.
  
 2. PLEASE NOTE ON THE PLAN THAT A REGULATOR REDUCING
 PRESSURE FROM 2 PSI TO THE PRESSURE REQUIREMENTS OF THE
 WATER HEATER SHALL BE PROVIDED. FBC FG 410.1
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-06-28 Cont ID  
Sent By aoliver Date 2023-06-28 Time 13:43 Rev Time 0.00
Received By aoliver Date 2023-06-26 Time 09:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-06-23 Cont ID  
Sent By lmarchan Date 2023-06-23 Time 11:50 Rev Time 0.00
Received By lmarchan Date 2023-06-20 Time 08:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-06-05 Cont ID  
Sent By aoliver Date 2023-06-05 Time 11:27 Rev Time 0.00
Received By aoliver Date 2023-05-25 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-05-12 Cont ID  
Sent By lmarchan Date 2023-05-12 Time 08:07 Rev Time 0.00
Received By lmarchan Date 2023-05-03 Time 09:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-21 Cont ID  
Sent By lmarchan Date 2023-03-21 Time 10:09 Rev Time 0.00
Received By lmarchan Date 2023-03-10 Time 13:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-26 Cont ID  
Sent By aoliver Date 2023-01-26 Time 10:24 Rev Time 0.00
Received By aoliver Date 2022-12-27 Time 16:03 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-07-03 Time 07:51 Sent To  
Notes
2023-07-03 07:52:33EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-01-25 Cont ID  
Sent By rmcphers Date 2023-01-25 Time 15:20 Rev Time 0.00
Received By rmcphers Date 2023-01-25 Time 15:20 Sent To  
Notes
2023-01-25 15:20:54PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-05-09 Cont ID  
Sent By medwards Date 2023-05-09 Time 06:30 Rev Time 0.00
Received By medwards Date 2023-05-09 Time 06:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-03-15 Cont ID  
Sent By medwards Date 2023-03-15 Time 13:09 Rev Time 0.00
Received By medwards Date 2023-03-15 Time 13:09 Sent To  
Notes
2023-03-15 13:09:542ND REVIEW FMC
 PERMIT: 22121052
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
  
  
 1) PROVIDE A DETAIL FOR THE LAUNDRY, DRYER DUCT.
 MATERIAL, SIZE, LENGTH AND TERMINATION LOCATION. FMC
 504
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-01-17 Cont ID  
Sent By medwards Date 2023-01-17 Time 13:43 Rev Time 0.00
Received By medwards Date 2023-01-17 Time 13:43 Sent To  
Notes
2023-01-17 13:43:401ST REVIEW FMC
 PERMIT: 22121052!0
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M6.1: THE RTU-2 AND RTU-3 DO NOT SHOW ANY
 OUTDOOR AIR IN THE EQUIPMENT SCHEDULE. PLEASE SHOW THE
 REQUIRED OUTDOOR AIR FOR EACH RTU AND PROVIDE THE
 OUTDOOR AIR CALCULATION FOR EACH BASED ON THE OCCUPANCY
 CLASSIFICATION. FMC 403.3.1.1 AND TABLE 403.3.1.1
  
 2) SHEET M2.1: IT APPEARS THE RTU-3 IS RECEIVING RETURN
 AIR FROM A STORAGE ROOM BY THE OFFICE. IF THIS IS A
 RETURN PLEASE REMOVE THIS RETURN DUCT FROM THE CLOSET.
 FMC 601.5 7
  
 3) SHOW THAT EACH RTU WILL MEET THE SMOKE DETECTOR
 REQUIREMENTS OF FMC 606.2.1 AND 606.2.2
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2023-06-22 Cont ID  
Sent By rwbrown Date 2023-06-22 Time 13:10 Rev Time 0.00
Received By rwbrown Date 2023-06-22 Time 13:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-05-05 Cont ID  
Sent By rwbrown Date 2023-05-05 Time 08:01 Rev Time 0.00
Received By rwbrown Date 2023-05-05 Time 08:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-03-13 Cont ID  
Sent By rwbrown Date 2023-03-13 Time 16:11 Rev Time 0.00
Received By rwbrown Date 2023-03-13 Time 16:11 Sent To  
Notes
2023-03-13 16:30:032ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
 2. THIS COMMENT NOT ADDRESSED. THIS COMMENT IS FOR HOT
 WATER DELIVERY. YOUR RESPONSE ADDRESSES TEMPERED WATER.
 THE WATER HEATER DETAIL SHOULD SHOW A MIXING VALVE.
 PER FBC 607.1.1, 613.1, PROVIDE A TEMPERATURE-ACTUATED
 MIXING VALVE, INSTALLED TO REDUCE WATER TEMPERATURES TO
 DEFINED LIMITS, SHALL COMPLY WITH ASSE 1017. SUCH VALVE
 SHALL BE INSTALLED AT THE HOT WATER SOURCE. THIS
 PROTECTION LEVEL IS IN ADDITION TO THE REQUIREMENTS
 NEEDED FOR PUBLIC HAND WASHING DICTATED BY FBC PL
 419.5, 607.1.2.
  
 3. DONE
  
 4. DONE
  
 5. 2020 FPC 905.4 - THE VENTS FOR THE SHOWERS ARE NOT
 ALLOWED TO BE HORIZONTAL WHILE DRY. EACH VENT MUST
 REMAIN VERTICAL UNTIL 6" ABOVE THE FIXTURE(S) SERVED.
  
 6. 2020 FPC 918.8 - AN AIR ADMITTANCE VALVE CANNOT BE
 USED TO VENT THE GREASE TRAP. THIS CREATES AN "AIR
 BOUND" TRAP. A VENT TO THE OPEN AIR IS REQUIRED.
  
 7. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE
 AT THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE
 SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR
 PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS
 APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. AFTER YOU HAVE THE PERMIT(S)
 GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE
 LETTER AND I WILL COMPLY THIS COMMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-09 Cont ID  
Sent By jesmith Date 2023-01-09 Time 16:30 Rev Time 0.00
Received By jesmith Date 2023-01-04 Time 16:48 Sent To  
Notes
2023-01-09 16:24:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22121052 2025 N DIXIE HWY
  
 1ST REVIEW
  
 A SEPARATE PERMIT FOR GREASE INTERCEPTOR IS REQUIRED TO
 BE SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT
 (AS APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD"
 (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR
 SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. A SEPARATE PERMIT IS
 REQUIRED HOWEVER A REVIEW OF THE SYSTEM UNDER THE MAIN
 PERMIT IS ALSO REQUIRED.
 AFTER YOU HAVE THE PERMIT(S) GENERATED, PLEASE NOTIFY
 ME AT [email protected] AND CC SAMANTHA HILL, CHIEF PLANS
 EXAMINER AT [email protected] AND RYAN BROWN, CHIEF
 PLUMBING INSPECTOR AT [email protected] VIA EMAIL WITH
 THE PERMIT NUMBER(S).
  
 PLUMBING COMMENTS: DENIED
  
 1. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS (SEE FBC PL 404.1) BUT IS TYPICALLY ADDRESSED
 ON THE ARCHITECTURAL PLANS. ANY COMMENTS CONCERNING
 THESE REQUIREMENTS MUST BE SATISFACTORILY ADDRESSED
 PRIOR TO A PLUMBING REVIEW APPROVAL.
 ***A) PLAN G1.2: PROVIDE ADDITIONAL DETAILS (PLAN AND
 ELEVATION) FOR STANDARD ROLL IN SHOWER WITH SEAT
 SHOWING DIMENSIONS, LOCATIONS AND HEIGHTS OF GRAB BARS,
 CONTROL VALVE, FAUCETS, SHOWER SPRAY UNIT. COMPLY WITH
 FBC ACC 608.2.2, 608.3.2, 608.5.2, 608.6, 609.4, 610.3,
 610.3.1.
 ***B) PROVIDE DETAIL FOR ACCESSIBLE WASHER AND DRYER
 SHOWING COMPLIANCE WITH FBC ACC 611.3
 ***C) PROVIDE CLEAR FLOOR SPACE FOR ACCESSIBLE WASHER
 AND DRYER SHOWING COMPLIANCE WITH FBC ACC 611.2, 305.
  
 2. PER FBC 607.1.1, 613.1, PROVIDE A
 TEMPERATURE-ACTUATED MIXING VALVE, INSTALLED TO REDUCE
 WATER TEMPERATURES TO DEFINED LIMITS, SHALL COMPLY WITH
 ASSE 1017. SUCH VALVE SHALL BE INSTALLED AT THE HOT
 WATER SOURCE. THIS PROTECTION LEVEL IS IN ADDITION TO
 THE REQUIREMENTS NEEDED FOR PUBLIC HAND WASHING
 DICTATED BY FBC PL 419.5, 607.1.2.
  
 3. IT APPEARS THE HOT WATER PIPING FROM THE HOT WATER
 SOURCE TO THE PUBLIC LAVATORIES EXCEEDS 2 FEET. REFER
 TO TABLE C404.5.1 FBC EC- THE 1/2 -INCH HOT WATER PIPE
 TO THE LAVATORY SHALL NOT EXCEED 2 FEET FROM THE HOT
 WATER SOURCE.
  
 4. RE: P-2.1, P-5.1; CIRCUIT VENTED BRANCH FOR WATER
 CLOSETS
 ***A) THE CIRCUIT VENT CONNECTION SHALL BE LOCATED
 BETWEEN THE TWO MOST UPSTREAM FIXTURE DRAINS (WATER
 CLOSETS). FBC PL 914.2
 ***B) FIXTURES OTHER THAN THE CIRCUIT VENTED FIXTURES
 DISCHARGING TO THE CIRCUIT VENTED BRANCH SHALL BE
 INDIVIDUALLY OR COMMON VENTED. FBC PL 914.5
  
 5. RE: P-2.1, P-5.1; SHOWER DRAINS
 ***A) BRANCH SHALL BE SIZED 3 INCH TO THE CONNECTION
 WITH MOST UPSTREAM SHOWER FIXTURE DRAIN. FBC PL TABLE
 915.2.2
 ***B) VENT SHALL CONNECT ABOVE THE CENTERLINE OF THE
 DRAIN OF THE HORIZONTAL DRAIN AND SHALL RISE VERTICALLY
 TO A POINT NOT LESS THAN 6 INCHES ABOVE THE FLOOD LEVEL
 RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED
 PER FBC PL 905.3 AND 905.4. O BE CLEAR, THERE SHALL BE
 NO HORIZONTAL TRAVEL BETWEEN THE BRANCH AND THE
 VERTICAL PORTION OF THE VENT.
 ***C) PER FBC PL 915.2.5, SHOWER FIXTURE DRAINS SHALL
 NOT EXCEED THE MAXIMUM ALLOWABLE DISTANCE FROM TRAP TO
 VENT AS ALLOWED IN FBC PL TABLE 909.1 UNLESS SIZED THE
 SAME AS THE BRANCH.
  
 6. TRAPPED FLOOR SINK DISCHARGING TO GREASE INTERCEPTOR
 SHALL BE VENTED. FBC PL 909.1
 PLEASE NOTE, A SEPARATE PERMIT FOR THE GREASE
 INTERCEPTOR IS REQUIRED.
  
 7. PLEASE PROVIDE SIZES AND MINIMUM SLOPES OF PRIMARY
 AND SECONDARY STORM DRAINS. FBC PL 1106.2, TABLE 1106.2
  
 8. PLEASE PROVIDE OVERFLOW SCUPPERS FOR PADEL COURT
 ROOF. FBC PL 1108.1
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2023-03-15 Cont ID  
Sent By rmcphers Date 2023-03-15 Time 10:06 Rev Time 0.00
Received By rmcphers Date 2023-03-15 Time 10:06 Sent To  
Notes
2023-03-15 10:07:56ROOFING SYSTEM TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-01-25 Cont ID  
Sent By rmcphers Date 2023-01-25 Time 15:21 Rev Time 0.00
Received By rmcphers Date 2023-01-25 Time 15:21 Sent To  
Notes
2023-01-25 15:21:26SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2023-06-27 Cont ID  
Sent By rmcphers Date 2023-06-27 Time 09:12 Rev Time 0.00
Received By rmcphers Date 2023-06-27 Time 09:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-06-22 Cont ID  
Sent By rmcphers Date 2023-06-22 Time 15:30 Rev Time 0.00
Received By rmcphers Date 2023-06-22 Time 15:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-05-26 Cont ID  
Sent By rmcphers Date 2023-05-26 Time 13:02 Rev Time 0.00
Received By rmcphers Date 2023-05-26 Time 13:02 Sent To  
Notes
2023-05-26 13:02:19SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A2.1 NEEDS TO BE SIGNED AND SEALED BY THE
 DESIGNER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-05-04 Cont ID  
Sent By rmcphers Date 2023-05-04 Time 11:25 Rev Time 0.00
Received By rmcphers Date 2023-05-04 Time 11:24 Sent To  
Notes
2023-05-04 11:25:04SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS SP1.2, A2.1, NEED TO BE SIGNED AND SEALED
 BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-03-15 Cont ID  
Sent By rmcphers Date 2023-03-15 Time 10:23 Rev Time 0.00
Received By rmcphers Date 2023-03-15 Time 10:23 Sent To  
Notes
2023-03-15 10:30:32SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS CVR, G1.0, G1.1, G1.2, SP1.0, SP1.1, SP1.2,
 LSP1.0, D1.0, D2.0, A1.0, A1.1, A1.2, A1.3, A1.4, A1.5,
 A2.1, A2.0, A3.0, A3.1, A4.0, A5.0, A5.1, A6.0, A6.1,
 A6.2, A7.0, S1.0, S2.1, S2.2, S4.4 DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-01-24 Cont ID  
Sent By mpeterso Date 2023-01-24 Time 13:23 Rev Time 0.00
Received By mpeterso Date 2023-01-24 Time 13:23 Sent To  
Notes
2023-01-24 13:24:08ALL PLANS PASSED SIGNATURE REVIEW. MP
2023-01-17 13:44:30MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 6 Status P Date 2023-06-28 Cont ID  
Sent By kdefranc Date 2023-06-28 Time 09:13 Rev Time 0.00
Received By kdefranc Date 2023-06-28 Time 09:13 Sent To  
Notes
2023-06-28 09:13:406/28/23 ??? PASSED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [SATISFIED]
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070).
 [SATISFIED]
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS; [WITHDRAWN]
 B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN]
 C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN]
 D. EXISTING USE(S); [SATISFIED]
 E. PROPOSED USE(S); [SATISFIED]
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 [SATISFIED]
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS; [WITHDRAWN]
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED]
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED]
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [SATISFIED]
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [SATISFIED]
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED]
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [SATISFIED]
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED]
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 Q. EXISTING PARCEL LINES; [SATISFIED]
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 [WITHDRAWN]
 S. EXISTING BUILDING HEIGHT; [WITHDRAWN]
 T. PROPOSED BUILDING HEIGHT; [WITHDRAWN]
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES;
 [WITHDRAWN]
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 [WITHDRAWN]
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES; [WITHDRAWN]
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 [WITHDRAWN]
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES. [WITHDRAWN]
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
 [WITHDRAWN]
  
 ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED]
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED]
  
 ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED:
 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1.,
 PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE
 CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418
 ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON
 THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [WITHDRAWN]
 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY
 OF TITLE FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE
 PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE
 CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010
 ON SHEET NUMBER SP1.0. [SATISFIED]
 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE
 FOOTAGE CALCULATION FOR PARCEL NUMBER
 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1,
 AND SP1.2. [SATISFIED]
 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT
 DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND
 SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK
 DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL
 LINE. [SATISFIED]
 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS
 OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING
 LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON
 THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE
 PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE
 SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE
 WALL NOTES. [SATISFIED]
 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY
 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING
 BUILDING IS NOT A PART OF THE PRIVATE PROPERTY,
 THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED
 PLANS. [SATISFIED]
 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT
 HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS
 HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE,
 PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS.
 [SATISFIED]
 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO
 LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET
 FROM THE PERMIT APPLICATION FILE. [SATISFIED]
 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE
 MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE
 OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC.
 [SATISFIED]
 19. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.J., IT
 HAS BEEN IDENTIFIED THAT THE EXISTING AND PROPOSED OPEN
 SPACE CALCULATIONS INDICATED ARE THE SAME, WHICH DOES
 NOT REFLECT THE PROPOSAL. THEREFORE, PLEASE UPDATE
 ACCORDINGLY. [SATISFIED]
 20. IN REFERENCE TO PREVIOUS REVIEW COMMENTS 3.M. AND
 3.O., DISCREPANCIES HAVE BEEN IDENTIFIED FOR THE
 PROPOSED BUILDING LOT COVERAGE CALCULATIONS INDICATED.
 THEREFORE, PLEASE UPDATE ACCORDINGLY. [NOT SATISFIED].
  
 PROVISO:
 PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY:
 1. PROOF OF AN APPROVED AND RECORDED UNITY OF TITLE OF
 THE TWO PARCELS MUST BE PROVIDED.
 2. APPROVAL OF INFORMAL SITE PLAN REVIEW 23-02
 (Z23040019) MUST BE OBTAINED.
 3. SEPARATE PERMITS FOR THE OVERALL SITE INCLUDING, BUT
 NOT LIMITED TO, THE LANDSCAPE, SIGNAGE, PARKING, PADEL
 COURTS, WALL/GATES, AND EXTERIOR LIGHTING MUST BE
 OBTAINED.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 5 Status F Date 2023-06-23 Cont ID  
Sent By kdefranc Date 2023-06-23 Time 11:42 Rev Time 0.00
Received By kdefranc Date 2023-06-23 Time 11:41 Sent To  
Notes
2023-06-23 11:42:206/23/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [SATISFIED]
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070).
 [SATISFIED]
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS; [WITHDRAWN]
 B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN]
 C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN]
 D. EXISTING USE(S); [SATISFIED]
 E. PROPOSED USE(S); [SATISFIED]
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 [SATISFIED]
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS; [WITHDRAWN]
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED]
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [SATISFIED]
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED]
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [SATISFIED]
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED]
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [SATISFIED]
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [PARTIALLY SATISFIED]
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 Q. EXISTING PARCEL LINES; [SATISFIED]
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 [WITHDRAWN]
 S. EXISTING BUILDING HEIGHT; [WITHDRAWN]
 T. PROPOSED BUILDING HEIGHT; [WITHDRAWN]
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES;
 [WITHDRAWN]
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 [WITHDRAWN]
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES; [WITHDRAWN]
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 [WITHDRAWN]
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES. [WITHDRAWN]
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
 [WITHDRAWN]
  
 ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED]
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED]
  
 ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED:
 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1.,
 PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE
 CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418
 ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON
 THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [WITHDRAWN]
 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY
 OF TITLE FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE
 PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE
 CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010
 ON SHEET NUMBER SP1.0. [SATISFIED]
 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE
 FOOTAGE CALCULATION FOR PARCEL NUMBER
 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1,
 AND SP1.2. [SATISFIED]
 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT
 DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND
 SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK
 DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL
 LINE. [SATISFIED]
 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS
 OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING
 LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON
 THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE
 PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE
 SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE
 WALL NOTES. [SATISFIED]
 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY
 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING
 BUILDING IS NOT A PART OF THE PRIVATE PROPERTY,
 THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED
 PLANS. [SATISFIED]
 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT
 HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS
 HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE,
 PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS.
 [SATISFIED]
 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO
 LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET
 FROM THE PERMIT APPLICATION FILE. [SATISFIED]
 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE
 MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE
 OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC.
 [SATISFIED]
 19. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.J., IT
 HAS BEEN IDENTIFIED THAT THE EXISTING AND PROPOSED OPEN
 SPACE CALCULATIONS INDICATED ARE THE SAME, WHICH DOES
 NOT REFLECT THE PROPOSAL. THEREFORE, PLEASE UPDATE
 ACCORDINGLY.
 20. IN REFERENCE TO PREVIOUS REVIEW COMMENTS 3.M. AND
 3.O., DISCREPANCIES HAVE BEEN IDENTIFIED FOR THE
 PROPOSED BUILDING LOT COVERAGE CALCULATIONS INDICATED.
 THEREFORE, PLEASE UPDATE ACCORDINGLY.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 4 Status F Date 2023-06-05 Cont ID  
Sent By kdefranc Date 2023-06-05 Time 11:08 Rev Time 0.00
Received By kdefranc Date 2023-06-05 Time 11:06 Sent To  
Notes
2023-06-05 11:07:096/5/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [SATISFIED]
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT
 SATISFIED]
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS; [WITHDRAWN]
 B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN]
 C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN]
 D. EXISTING USE(S); [SATISFIED]
 E. PROPOSED USE(S); [SATISFIED]
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 [NOT SATISFIED]
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS; [WITHDRAWN]
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 Q. EXISTING PARCEL LINES; [SATISFIED]
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 [WITHDRAWN]
 S. EXISTING BUILDING HEIGHT; [WITHDRAWN]
 T. PROPOSED BUILDING HEIGHT; [WITHDRAWN]
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES;
 [WITHDRAWN]
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 [WITHDRAWN]
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES; [WITHDRAWN]
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 [WITHDRAWN]
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES. [WITHDRAWN]
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
 [WITHDRAWN]
  
 ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [SATISFIED]
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [SATISFIED]
  
 ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED:
 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1.,
 PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE
 CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418
 ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON
 THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [WITHDRAWN]
 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY
 OF TITLE FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE
 PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE
 CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010
 ON SHEET NUMBER SP1.0. [SATISFIED]
 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE
 FOOTAGE CALCULATION FOR PARCEL NUMBER
 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1,
 AND SP1.2. [NOT SATISFIED]
 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT
 DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND
 SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK
 DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL
 LINE. [SATISFIED]
 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS
 OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING
 LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON
 THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE
 PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE
 SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE
 WALL NOTES. [PARTIALLY SATISFIED]
 15. IT HAS BEEN IDENTIFIED THAT THE APPROXIMATELY
 12-FOOT WIDE BY 50-FOOT LONG AREA EAST OF THE EXISTING
 BUILDING IS NOT A PART OF THE PRIVATE PROPERTY,
 THEREFORE, PLEASE PROVIDE A CURRENT SURVEY AND REVISED
 PLANS.
 16. IN REFERENCE TO PREVIOUS REVIEW COMMENT 3.F., IT
 HAS BEEN IDENTIFIED THAT TWO DIFFERENT CALCULATIONS
 HAVE BEEN PROVIDED ON SHEET NUMBER SP1.0. THEREFORE,
 PLEASE PROVIDE CONSISTENT INFORMATION ON THE PLANS.
 17. SINCE YOU HAVE INDICATED SHEET NUMBER SP1.2 IS NO
 LONGER A PART OF THE SCOPE, PLEASE REMOVE SAID SHEET
 FROM THE PERMIT APPLICATION FILE.
 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 14., PLEASE
 MAKE THOSE REVISIONS TO THE PLANS THAT DEMONSTRATE THE
 OVERALL SITE, SUCH AS SHEET NUMBER SP1.1, ETC.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 3 Status F Date 2023-05-11 Cont ID  
Sent By kdefranc Date 2023-05-11 Time 17:05 Rev Time 0.00
Received By kdefranc Date 2023-05-11 Time 17:04 Sent To  
Notes
2023-05-11 17:05:345/11/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [SATISFIED]
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT
 SATISFIED]
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS; [WITHDRAWN]
 B. CURRENT ZONING DESIGNATIONS; [WITHDRAWN]
 C. FUTURE LAND USE CLASSIFICATIONS; [WITHDRAWN]
 D. EXISTING USE(S); [SATISFIED]
 E. PROPOSED USE(S); [NOT SATISFIED]
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 [SATISFIED]
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS; [WITHDRAWN]
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 Q. EXISTING PARCEL LINES; [PARTIALLY SATISFIED]
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 [WITHDRAWN]
 S. EXISTING BUILDING HEIGHT; [WITHDRAWN]
 T. PROPOSED BUILDING HEIGHT; [WITHDRAWN]
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES;
 [WITHDRAWN]
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 [WITHDRAWN]
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES; [WITHDRAWN]
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 [WITHDRAWN]
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES. [WITHDRAWN]
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
 [WITHDRAWN]
  
 ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [NOT
 SATISFIED]
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [NOT
 SATISFIED]
  
 ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED:
 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1.,
 PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE
 CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418
 ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON
 THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [WITHDRAWN]
 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY
 OF TITLE FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE
 PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 [WITHDRAWN]
 11. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.C., PLEASE IDENTIFY/INDICATE THE FUTURE LAND USE
 CLASSIFICATION OF PARCEL NUMBER 74-43-43-16-15-001-0010
 ON SHEET NUMBER SP1.0.
 12. PLEASE IDENTIFY/INDICATE THE AREA ACREAGE/SQUARE
 FOOTAGE CALCULATION FOR PARCEL NUMBER
 74-43-43-16-15-001-0010 ON SHEET NUMBERS SP1.0, SP1.1,
 AND SP1.2.
 13. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER
 3.Q., PLEASE DEMONSTRATE/DELINEATE THE PARCEL LINE THAT
 DIVIDES THE TWO PARCELS ON SHEET NUMBERS SP1.1 AND
 SP1.2. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE SETBACK
 DIMENSION OF THE BUILDING FROM THAT SPECIFIC PARCEL
 LINE.
 14. PLEASE GRAY OUT THE PROPOSED SITE WORK IMPROVEMENTS
 OUTSIDE OF THE BUILDING AREA (INCLUDING THE PARKING
 LOT, PADEL COURTS, SITE LIGHTING, SITE WALL, ETC.) ON
 THE PLANS. PLEASE PROVIDE NOTES, ON THE PLANS FOR THE
 PROPOSED SITE WORK IMPROVEMENTS, STATING REQUIRE
 SEPARATE PERMITS SIMILAR TO THE PARKING LOT AND SITE
 WALL NOTES.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 2 Status F Date 2023-03-21 Cont ID  
Sent By kdefranc Date 2023-03-21 Time 09:46 Rev Time 0.00
Received By kdefranc Date 2023-03-21 Time 09:45 Sent To  
Notes
2023-03-21 09:46:243/21/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070). [SATISFIED]
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070). [NOT
 SATISFIED]
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS; [PARTIALLY SATISFIED]
 B. CURRENT ZONING DESIGNATIONS; [PARTIALLY SATISFIED]
 C. FUTURE LAND USE CLASSIFICATIONS; [NOT SATISFIED]
 D. EXISTING USE(S); [SATISFIED]
 E. PROPOSED USE(S); [NOT SATISFIED]
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 [SATISFIED]
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS; [NOT SATISFIED]
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010; [NOT SATISFIED]
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010; [NOT SATISFIED]
 Q. EXISTING PARCEL LINES; [PARTIALLY SATISFIED]
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 [NOT SATISFIED]
 S. EXISTING BUILDING HEIGHT; [NOT SATISFIED]
 T. PROPOSED BUILDING HEIGHT; [NOT SATISFIED]
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES; [NOT
 SATISFIED]
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 [NOT SATISFIED]
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES; [NOT SATISFIED]
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 [NOT SATISFIED]
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES. [NOT SATISFIED]
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
 [WITHDRAWN]
  
 ADDITIONAL REVIEW COMMENTS (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM. [NOT
 SATISFIED]
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [NOT
 SATISFIED]
  
 ADDITIONAL REVIEW COMMENTS TO BE ADDRESSED:
 8. IN REFERENCE TO PREVIOUS REVIEW COMMENT NUMBER 1.,
 PLEASE PROVIDE THE FINAL ORDER ASSOCIATED WITH THE
 CLASS B SPECIAL USE PERMIT APPROVAL (ZBA CASE NO. 3418
 ??? Z22080030) FOR THE PROPOSED PARKING LOT LOCATED ON
 THE ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070).
 9. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 SITE REQUIRES PRIOR APPROVAL AND RECORDATION OF A UNITY
 OF TITLE FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
 10. IN ACCORDANCE WITH THE CLASS B SPECIAL USE PERMIT
 APPROVAL (ZBA CASE NO. 3418 ??? Z22080030), THE SUBJECT
 PROJECT REQUIRES PRIOR APPROVAL OF AN INFORMAL SITE
 PLAN REVIEW APPLICATION FOR BOTH PARCEL NUMBERS
 74-43-43-16-15-001-0070 AND 74-43-43-16-15-001-0010.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-01-06 Cont ID  
Sent By KDefranc Date 2023-01-06 Time 14:00 Rev Time 0.00
Received By kdefranc Date 2023-01-06 Time 14:00 Sent To  
Notes
2023-01-06 14:00:291/6/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. A CLASS B SPECIAL USE PERMIT APPROVAL MUST BE
 OBTAINED FOR THE PROPOSED PARKING LOT LOCATED ON THE
 ADJACENT PARCEL TO THE WEST (PARCEL NUMBER
 74-43-43-16-15-001-0070).
 2. A REZONING APPROVAL MUST BE OBTAINED FOR THE
 PROPOSED PADEL COURT LOCATED ON THE ADJACENT PARCEL TO
 THE WEST (PARCEL NUMBER 74-43-43-16-14-001-0070).
 3. PLEASE SUBMIT REVISED SITE PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL NUMBERS;
 B. CURRENT ZONING DESIGNATIONS;
 C. FUTURE LAND USE CLASSIFICATIONS;
 D. EXISTING USE(S);
 E. PROPOSED USE(S);
 F. TOTAL SITE AREA ACREAGE/SQUARE FOOTAGE CALCULATION;
 G. AREA ACREAGE/SQUARE FOOTAGE CALCULATIONS FOR THE TWO
 PARCELS;
 H. EXISTING IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010;
 I. PROPOSED IMPERMEABLE SURFACE LOT COVERAGE SQUARE
 FOOTAGE AND PERCENTAGE CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010;
 J. PROPOSED OPEN SPACE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 K. PROPOSED LANDSCAPE AREA SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 L. EXISTING BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 M. PROPOSED BUILDING LOT COVERAGE SQUARE FOOTAGE AND
 PERCENTAGE CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 N. EXISTING BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 O. PROPOSED BUILDING FLOOR AREA SQUARE FOOTAGE
 CALCULATION IN RELATION TO PARCEL NUMBER
 74-43-43-16-15-001-0010;
 P. PROPOSED TOTAL FLOOR AREA CALCULATION IN RELATION TO
 PARCEL NUMBER 74-43-43-16-15-001-0010;
 Q. EXISTING PARCEL LINES;
 R. PROPOSED SETBACK DIMENSIONS TO ALL PARCEL LINES;
 S. EXISTING BUILDING HEIGHT;
 T. PROPOSED BUILDING HEIGHT;
 U. PROPOSED NUMBER OF BICYCLE PARKING SPACES;
 V. DEPICTION/TYPICAL DETAIL OF THE PROPOSED BIKE RACKS;
 4. PLEASE SUBMIT A REVISED SITE LIGHTING PLAN
 IDENTIFYING/INDICATING/DEMONSTRATING THE FOLLOWING:
 A. EXISTING PARCEL LINES;
 B. PROPOSED HEIGHT OF ALL OUTDOOR ILLUMINATION; AND
 C. PROPOSED INTENSITY OF ALL OUTDOOR ILLUMINATION TO
 ALL PARCEL LINES.
 5. IT HAS BEEN IDENTIFIED THAT THE HEIGHT OF THE
 PROPOSED STAIR ENCLOSURE EXCEEDS THE MAXIMUM HEIGHT
 ALLOWED ACCORDING TO THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS SUBSECTION 94-306(A).
 THEREFORE, PLEASE REVISE THE ELEVATIONS, ACCORDINGLY.
  
 ADDITIONAL REVIEW COMMENT (THAT REQUIRES A SEPARATE
 PERMIT) TO BE ADDRESSED:
 6. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION OR A
 LANDSCAPE CONDITIONAL APPROVAL PERMIT FORM.
 7. PLEASE SUBMIT A SIGN PERMIT APPLICATION.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  