Plan Review Details - Permit 22121038
| Plan Review Stops For Permit 22121038 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-03 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-03 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-03-20 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-03-20 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-02-15 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-02-15 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2023-02-15 13:11:03 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. REVIEW THE ONE-LINE DIAGRAM, WHICH IS SHOWING THE | | | 60A DISC CU-1 POWERED FROM THE ELECTRICAL METER AND | | | PANEL A SCHEDULE SHOWS A 60 AMPS BREAKER. NEC 215.5 | | | 2. A/C UNIT MAIN HOUSE - PANEL A SCHEDULE ONLY SHOWS | | | INFORMATION OF THE AIR HANDLER UNIT FEEDER. IT IS NOT | | | SHOWING INFORMATION OF THE A/C CONDENSER FEEDER AND | | | PROTECTION. NEC 408.4(A) | | | 3. PROVIDE INFORMATION OF THE EGC FOR THE PANEL PNL 'A' | | | 200A AND THE SUB PNL 'B' CABANA 60A POWERED FROM THE | | | PANEL PNL 'A' 200A. NEC 250.122 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-12-30 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-12-30 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-21 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-16 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-03 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-02-13 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-15 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-15 |
Time |
06:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-17 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-15 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-15 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-21 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-21 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-03 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-03 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2023-03-03 09:46:32 | ARCHITECT SIGNATURE DIGIITALLY APPROVED | | 2023-02-15 16:20:35 | PLUMBING RISER & ELECTRIC- SHEET A1.21 APPROVED. | | 2023-02-15 06:34:05 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-12-30 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-12-30 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy