| Plan Review Stops For Permit 22120974 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-01-03 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-03 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-12-27 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-12-27 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2022-12-27 10:45:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PLAN STATES OCCUPANCY CLASSIFICATION IS R2. THIS | | | OCCUPANCY REQUIRES USE OF THE FLORIDA BUILDING CODE, | | | BUILDING (APARTMENTS, RESIDENTIAL CONDOS). IT APPEARS | | | THAT THIS IS A SINGLE FAMILY HOME SO CORRECT OCCUPANCY | | | IS ONE-OR-TWO-FAMILY DWELLING WHICH WOULD BE GOVERNED | | | BY THE FBC RESIDENTIAL CODE. PLEASE REVISE PLAN | | | ACCORDINGLY. | | | | | | IF THIS IS R2, ADVISE, AND THE PERMIT TYPE WIILL BE | | | CHANGED, A FIRE PLAN REVIEW WILL BE REQUIRED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-10 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-10 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2022-12-28 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2022-12-28 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2022-12-28 08:36:15 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. | | | NEC 215.2, 220 | | | | | | 2. DRAWING IS NOT SHOWING INFORMATION OF ELECTRICAL | | | PANEL (LOCATION, CIRCUITS OR PANEL SCHEDULE, RATING, | | | ETC) AS PER NEC 230 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-02-07 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-12-30 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-12-30 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-12-22 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-28 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-28 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-03 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-29 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-12-29 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-02-07 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-02-07 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2022-12-28 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2022-12-28 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2022-12-28 14:05:33 | THE PRIVATE PROVIDER PLAN REVIEW AUSIT FAILED | | | THE NOTICE TO BUILDING OFFICIAL IS SIGNED BY THE | | | CONTRACOR NOT THE FEE OWNER . 553.791 (2)(A) F.S. SAYS | | | THE FEE OWNER???S CONTRACTOR UPON WRITTEN AUTHORIZATION | | | FROM THE FEE OWNER MAY CHOOSE TO USE A PRIVATE | | | PROVIDER. | | | PLEASE PROVIDE THE FEE OWNER???S AUTHORIZATION FOR THE | | | CONTRACTOR TO USE A PRIVATE PROVIDER | | | | | | ALSO THE CERTIFICATE OF INSURANCE IS REQUIRED FOR THIS | | | PERMIT AND THE RESUMES FOR THE PRIVATE PROVIDER AND ANY | | | AUTHORIZED INSPECTOR OF THE PRIVATE PROVIDER FIRM | | | | | | | | | RICHARD GATHRIGHT | | | ASSISTANT BUILDING OFFICIAL | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-28 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-28 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|