Plan Review Details - Permit 22120924
| Plan Review Stops For Permit 22120924 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-13 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-13 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-09 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-09 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2023-01-09 08:34:12 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING 2ND REVIEW DENIED: | | | | | | FBC - R 301.2.1.2 SUBMIT AN INSTALLATION SCHEDULE AND | | | KEY PLAN FOR THE STORM PANELS. SPECIFY THE OPENING | | | SIZE, THE WIND PRESSURES, TYPE OF ANCHOR, ANCHOR | | | SPACING, EDGE DISTANCE, PANEL LENGTH, PANEL SPAN, | | | SEPARATION DISTANCE FROM PANEL TO GLASS AND THE | | | APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | | DRAWINGS. FOR YOUR CONVENIENCE I HAVE INCLUDED AN | | | INSTALLATION SCHEDULE WITHIN YOUR DIGITAL PORTAL THAT | | | HAS MAY BE USED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-05 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-05 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2023-01-05 14:18:15 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC - R 301.2.1.2 SUBMIT AN INSTALLATION SCHEDULE AND | | | KEY PLAN FOR THE STORM PANELS. SPECIFY THE OPENING | | | SIZE, THE WIND PRESSURES, TYPE OF ANCHOR, ANCHOR | | | SPACING, EDGE DISTANCE, PANEL LENGTH, PANEL SPAN, | | | SEPARATION DISTANCE FROM PANEL TO GLASS AND THE | | | APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | | DRAWINGS. FOR YOUR CONVENIENCE I HAVE INCLUDED AN | | | INSTALLATION SCHEDULE WITHIN YOUR DIGITAL PORTAL THAT | | | HAS MAY BE USED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-13 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-12 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-09 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-06 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-05 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-20 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-05 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-05 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |