Plan Review Details - Permit 22120704
| Plan Review Stops For Permit 22120704 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-02-03 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-02-03 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-01-23 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-01-23 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2023-01-23 09:05:43 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SITE PLAN AND SURVEY DO NOT MATCH. PLEASE | | | CLARIFY. FBC 107.2.1 | | | | | | 2) THE STRUCTURAL PLANS DO NOT SHOW THE SUNSHELF OR SPA | | | THAT IS SHOWN ON THE SURVEY. FBC 107.2.1 | | | | | | 3) I COULD NOT FIND THE PERMIT FOR THE FENCE. IN ORDER | | | FOR THE EXISTING FENCE TO BE USED AS THE SWIMMING POOL | | | BARRIER, IT IS REQUIRED TO BE PERMITTED AND BE LOCATED | | | ON THE POOL OWNER'S PROPERTY AND BE UNDER THE CONTROL | | | OF THE POOL OWNER. FBC-R4501.17 | | | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2022-12-20 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2022-12-20 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-02-03 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-01-26 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-01-23 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-12-16 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-22 |
Time |
06:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-22 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-02-03 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-02-03 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-22 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-22 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-31 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-31 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-03 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-03 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2023-01-03 09:18:19 | 1/3/2022 | | | FAILED | | | | | | THE SITE PLAN AND SURVEY ARE SHOWING TWO DIFFERENT POOL | | | LAYOUTS AND SETBACKS. | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] |
|
|
|