| Plan Review Stops For Permit 22120570 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-14 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-27 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2023-02-27 16:07:16 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVAL PENDING APPROVAL OF SIGNATURE | | | REVIEW. | | | | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. THE ENGINEER'S LETTER IDENTIFIED AS "PV14 LETTER | | | BRADLEY" LOCATED WITHIN THE SUPPORTING DOCUMENTS | | | APPEARS TO BE A SCAN OF AN ORIGINAL ENGINEER HAND | | | SIGNED/SEALED LETTER. | | | | | | A. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND | | | SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A | | | VALID DIGITAL SIGNATURE. | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C. | | | B. PLEASE SUBMIT ENGINEER'S LETTER WITH A VALID DIGITAL | | | SIGNATURE. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | 2. FBC B TABLE 1604.5 & FBC B 1609. THE WIND LOAD SHOWN | | | ON THE ENGINEER'S LETTER, IDENTIFIED AS "PV14 LETTER | | | BRADLEY", IS FOR 169 MPH. THIS APPEARS TO BE FOR A RISK | | | CATEGORY 2. AS PER THE FLORIDA BUILDING CODE THE WIND | | | LOAD, WITHIN THE ENGINEER'S LETTER, NEEDS TO BE | | | ADJUSTED TO 170 MPH. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-06 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-06 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2023-02-06 10:55:22 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVAL PENDING APPROVAL OF SIGNATURE | | | REVIEW. | | | | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ELECTRIC PLAN SHEETS AND ENGINEER'S LETTER DO | | | NOT HAVE 3RD PARTY VERIFIABLE DIGITAL SIGNATURES FROM | | | DESIGN PROFESSIONAL. | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND | | | SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A | | | VALID DIGITAL SIGNATURE. | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C. | | | | | | 2. SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-02-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-23 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-23 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-01 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-01 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-01-23 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-03 |
Time |
17:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-10 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-06 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-19 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-14 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-27 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2023-02-27 16:09:36 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW DENIED: | | | | | | THE ENGINEER'S LETTER IDENTIFIED AS "PV14 LETTER | | | BRADLEY" APPEARS TO BE A SCAN OF AN ORIGINAL ENGINEER | | | HAND SIGNED/SEALED LETTER. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED DOCUMENT IS NOT CONSIDERED AN ORIGINAL. | | | | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) DOCUMENT: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | 2023-02-23 14:39:27 | ELECTRICAL PAGE SIGNATURE APPROVED JLEAHY |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-06 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-06 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2023-02-06 10:45:36 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW DENIED: | | | | | | THE ENGINEER'S LETTER AND ALL ELECTRIC PLAN SHEETS DO | | | NOT HAVE 3RD PARTY VERIFIABLE DIGITAL SIGNATURES FROM | | | DESIGN PROFESSIONAL. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | 2023-02-01 14:06:09 | SIGNATURE ON ELECTRICAL PAGES NOT VERIFIABLE, JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-22 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-22 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-01-23 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-01-23 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|