| Plan Review Stops For Permit 22120478 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-01-10 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-01-10 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2023-01-10 15:40:16 | SECONDARY ADDRESS NOT REQUIRED AS ZONING HAS NOT | | | APPROVED A SECONDARY UNIT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-12-13 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-12-13 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2022-12-13 11:39:17 | ADDRESS APPROPRIATE FOR THE FRONT BUILDING, THE REAR | | | BUILDING IS BEING CHANGED FROM A GARAGE INTO HABITABLE | | | SPACE. A SECONDARY ADDRESS MAY NEED TO BE ASSIGNED IF | | | ZONING APPROVES A SECONDARY UNIT. PLEASE CONTACT | | | [email protected] OR CALL 561-805-6659 ONCE ZONING | | | APPROVES THEIR REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
Cthroop |
Date |
2023-01-18 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-17 |
Time |
06:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-30 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-30 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2022-12-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2022-12-16 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2022-12-16 14:53:58 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. | | | NEC 215.2, 220, 408.30 | | | | | | 2. SMOKE ALARMS (SMOKE DETECTION) SYSTEM AND CO (CARBON | | | MONOXIDE) DETECTION SYSTEM SHALL BE PROVIDED IN | | | ACCORDANCE WITH NFPA 72, FBC 907, IRC 314, IRC 315 | | | | | | 3. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER | | | NEC 440.14 OR IRC E4101.5 | | | DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN | | | SIGHT FROM AND READILY ACCESSIBLE??? FROM THE | | | AIR-CONDITIONING EQUIPMENT. | | | | | | 4. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11 | | | THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION | | | FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS | | | APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING | | | OCCUPANCIES | | | | | | 5. THE ONE-LINE DIAGRAM IS NOT SHOWING INFORMATION OF | | | SERVICE EQUIPMENT DISCONNECT (SERVICE OVERCURRENT | | | PROTECTION) AS PER NEC 230 | | | | | | 6. AT LEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT | | | SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN | | | ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC | | | POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS AS PER | | | NEC 210.11(C)(4) | | | | | | 7. AT LEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT | | | SHALL BE PROVIDED TO SUPPLY THE BATHROOM(S) RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS AS | | | PER NEC 210.11(C)(3) | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-17 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-17 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-12-20 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-12-20 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2022-12-20 12:56:17 | PLEASE ENSURE THAT ALL WINDOWS WILL HAVE EXTERNAL | | | DIMENSIONAL MUNTINS AND CLEAR GLASS (LOW E PERMITTED ON | | | SIDES AND REAR) | | | | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-31 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-24 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-18 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-02-07 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-03 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2023-02-07 07:53:13 | NO IMPACT FEES DUE. LEM | | 2023-02-03 13:45:50 | EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-17 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2023-01-18 10:50:55 | NEW ELECTRICAL AND PLUMBING PLANS REQUIRED. CT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-21 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-21 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-25 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-25 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-14 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-12-13 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2022-12-14 08:47:55 | 1ST PLUMBING REVIEW GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC P3107.1 - THE WATER CLOSET CANNOT USE A | | | SINK ON ANOTHER FLOOR LEVEL IN CONJUCTION AS A COMMON | | | VENT. IF COMMON VENTED, THE TWO FIXTURES MUST BE ON THE | | | SAME LEVEL. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-17 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2023-01-18 10:22:35 | NO ROOFING PROPOSED FOR THIS SUBMITTAL. EXISTING | | | ROOFING TO REMAIN. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-31 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-31 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-18 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-17 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2022-12-21 16:50:35 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
hist |
Date |
2022-12-20 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-12-20 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2022-12-20 12:39:53 | REAR BUILDING NOT PERMITTED AS ADDITIONAL UNIT, BUT IS | | | PERMITTED AS SHOWN IN PLANS AS HABITABLE SPACE. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|