Plan Review Details - Permit 22120478
Plan Review Stops For Permit 22120478
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-01-10 Cont ID  
Sent By cpuell Date 2023-01-10 Time 15:40 Rev Time 0.00
Received By cpuell Date 2023-01-10 Time 15:40 Sent To  
Notes
2023-01-10 15:40:16SECONDARY ADDRESS NOT REQUIRED AS ZONING HAS NOT
 APPROVED A SECONDARY UNIT.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-12-13 Cont ID  
Sent By cpuell Date 2022-12-13 Time 11:39 Rev Time 0.00
Received By cpuell Date 2022-12-13 Time 11:39 Sent To  
Notes
2022-12-13 11:39:17ADDRESS APPROPRIATE FOR THE FRONT BUILDING, THE REAR
 BUILDING IS BEING CHANGED FROM A GARAGE INTO HABITABLE
 SPACE. A SECONDARY ADDRESS MAY NEED TO BE ASSIGNED IF
 ZONING APPROVES A SECONDARY UNIT. PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 ONCE ZONING
 APPROVES THEIR REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-01-18 Cont ID  
Sent By Cthroop Date 2023-01-18 Time 10:49 Rev Time 0.00
Received By cthroop Date 2023-01-17 Time 06:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-01-30 Cont ID  
Sent By rperdomo Date 2023-01-30 Time 11:14 Rev Time 0.00
Received By rperdomo Date 2023-01-30 Time 11:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By rperdomo Date 2022-12-16 Time 14:54 Rev Time 0.00
Received By rperdomo Date 2022-12-16 Time 13:26 Sent To  
Notes
2022-12-16 14:53:58FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE.
 NEC 215.2, 220, 408.30
  
 2. SMOKE ALARMS (SMOKE DETECTION) SYSTEM AND CO (CARBON
 MONOXIDE) DETECTION SYSTEM SHALL BE PROVIDED IN
 ACCORDANCE WITH NFPA 72, FBC 907, IRC 314, IRC 315
  
 3. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER
 NEC 440.14 OR IRC E4101.5
 DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN
 SIGHT FROM AND READILY ACCESSIBLE??? FROM THE
 AIR-CONDITIONING EQUIPMENT.
  
 4. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES
  
 5. THE ONE-LINE DIAGRAM IS NOT SHOWING INFORMATION OF
 SERVICE EQUIPMENT DISCONNECT (SERVICE OVERCURRENT
 PROTECTION) AS PER NEC 230
  
 6. AT LEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT
 SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN
 ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC
 POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS AS PER
 NEC 210.11(C)(4)
  
 7. AT LEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT
 SHALL BE PROVIDED TO SUPPLY THE BATHROOM(S) RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS AS
 PER NEC 210.11(C)(3)
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2023-01-17 Cont ID  
Sent By rwbrown Date 2023-01-17 Time 12:45 Rev Time 0.00
Received By rwbrown Date 2023-01-17 Time 12:33 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-12-20 Cont ID  
Sent By amhamilt Date 2022-12-20 Time 12:54 Rev Time 0.00
Received By amhamilt Date 2022-12-20 Time 12:54 Sent To  
Notes
2022-12-20 12:56:17PLEASE ENSURE THAT ALL WINDOWS WILL HAVE EXTERNAL
 DIMENSIONAL MUNTINS AND CLEAR GLASS (LOW E PERMITTED ON
 SIDES AND REAR)
  
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-31 Cont ID  
Sent By mpeterso Date 2023-01-31 Time 11:41 Rev Time 0.00
Received By mpeterso Date 2023-01-24 Time 12:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-18 Cont ID  
Sent By cthroop Date 2023-01-18 Time 10:49 Rev Time 0.00
Received By cthroop Date 2023-01-18 Time 10:49 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-02-07 Cont ID  
Sent By lmarchan Date 2023-02-07 Time 07:53 Rev Time 0.00
Received By lmarchan Date 2023-02-03 Time 13:45 Sent To  
Notes
2023-02-07 07:53:13NO IMPACT FEES DUE. LEM
2023-02-03 13:45:50EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-01-18 Cont ID  
Sent By cthroop Date 2023-01-18 Time 10:49 Rev Time 0.00
Received By cthroop Date 2023-01-17 Time 06:41 Sent To  
Notes
2023-01-18 10:50:55NEW ELECTRICAL AND PLUMBING PLANS REQUIRED. CT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-12-21 Cont ID  
Sent By medwards Date 2022-12-21 Time 16:49 Rev Time 0.00
Received By medwards Date 2022-12-21 Time 16:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-01-25 Cont ID  
Sent By rwbrown Date 2023-01-25 Time 07:55 Rev Time 0.00
Received By rwbrown Date 2023-01-25 Time 07:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-12-14 Cont ID  
Sent By rwbrown Date 2022-12-14 Time 08:42 Rev Time 0.00
Received By rwbrown Date 2022-12-13 Time 06:42 Sent To  
Notes
2022-12-14 08:47:551ST PLUMBING REVIEW GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC P3107.1 - THE WATER CLOSET CANNOT USE A
 SINK ON ANOTHER FLOOR LEVEL IN CONJUCTION AS A COMMON
 VENT. IF COMMON VENTED, THE TWO FIXTURES MUST BE ON THE
 SAME LEVEL.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-01-18 Cont ID  
Sent By cthroop Date 2023-01-18 Time 10:21 Rev Time 0.00
Received By cthroop Date 2023-01-17 Time 06:41 Sent To  
Notes
2023-01-18 10:22:35NO ROOFING PROPOSED FOR THIS SUBMITTAL. EXISTING
 ROOFING TO REMAIN. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-01-31 Cont ID  
Sent By mpeterso Date 2023-01-31 Time 11:38 Rev Time 0.00
Received By mpeterso Date 2023-01-31 Time 11:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-01-18 Cont ID  
Sent By cthroop Date 2023-01-18 Time 10:47 Rev Time 0.00
Received By cthroop Date 2023-01-17 Time 06:41 Sent To  
Notes
2022-12-21 16:50:35MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-12-20 Cont ID  
Sent By hist Date 2022-12-20 Time 12:38 Rev Time 0.00
Received By amhamilt Date 2022-12-20 Time 12:38 Sent To  
Notes
2022-12-20 12:39:53REAR BUILDING NOT PERMITTED AS ADDITIONAL UNIT, BUT IS
 PERMITTED AS SHOWN IN PLANS AS HABITABLE SPACE.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  