| Plan Review Stops For Permit 22120141 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-04-11 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-04-11 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2023-04-11 10:29:09 | ZONING DID NOT APPROVE A SECONDARY UNIT, NO ADDITIONAL | | | ADDRESS NEEDED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-14 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2023-02-14 15:43:33 | PARCEL NEEDS TO BE READDRESSED PLEASE SEE COMMENTS | | | UNDER 22120135. A SECONDARY ADDRESS MAY NEED TO BE | | | ASSIGNED IF ZONING APPROVES A SECONDARY UNIT. PLEASE | | | CONTACT [email protected] OR CALL 561-805-6659 ONCE | | | ZONING APPROVES THEIR REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-26 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-26 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2023-07-26 14:37:36 | ACCESSORY STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE PLANS HAVE BEEN REVISED TO SHOW A WOOD ROOF DECK | | | - PRODUCT APPROVAL 17-0511.03 IS FOR A STEEL ROOF DECK | | | - PLEASE REVISE THE ROOF SYSTEM PRODUCT APPROVAL. IN | | | THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK - | | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | | ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON | | | THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL | | | SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT | | | OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A | | | HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | | APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE | | | PRODUCT APPROVAL. | | | | | | 2) PLEASE PROVIDE A PRODUCT APPROVAL FOR THE TILE | | | ROOFING - PLEASE CIRCLE THE ROOF TILE ATTACHMENT TYPE | | | IN THE PRODUCT APPROVAL. ALL PRODUCT APPROVALS NEED TO | | | BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD FBC WPB 107.3.4 | | | | | | 3) THE EXTERIOR WALL CLADDING SYSTEM ON DRAWING A-5.00 | | | IS DIFFERENT THEN THE STRUCTURAL DRAWINGS WHICH SHOW | | | STRUCTURAL SHEATHING THE PRODUCT APPROVAL PROVIDED IS | | | ALSO DIFFERENT - PLEASE SHOW ALL EXTERIOR WALL CLADDING | | | COMPONETS SIZE, THICKNESS AND ATTACHMENTS - FBC WPB | | | 107.2.1 | | | | | | 4) PLEASE SHOW THE EXTERIOR WALL WATER RESISTIVE | | | BARRIER - FBC R703.2 WATER-RESISTIVE BARRIER. | | | ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND | | | BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR | | | OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED | | | OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. | | | | | | 5) PRODUCT APPROVAL FOR THE EXTERIOR WALL CLADDING WILL | | | NEED TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD - FBC WPB 107.3.4 | | | | | | 6) PRODUCT APPROVAL FL20468 -R5 NEEDS TO BE REVIEWED | | | AND MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD | | | - FBC WPB 107.3.4 | | | | | | 7) PRODUCT APPROVAL FL23358-R5 NEEDS TO BE REVIEWED AND | | | MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD - | | | FBC WPB 107.3.4 | | | | | | 8) PRODUCT APPROVAL FL26095-R3 NEEDS TO BE REVIEWED AND | | | MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD - | | | FBC WPB 107.3.4 | | | | | | 9) PRODUCT APPROVAL NOA 19-0305.03 NEEDS TO BE REVIEWED | | | AND MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD | | | - FBC WPB 107.3.4 | | | | | | 10) PLEASE SHOW THE STAIR RISER AND TREAD DEPTH - FBC | | | R311.7.5.1 RISERS. FBC R311.7.5.2 TREADS. | | | | | | 11) PLEASE SHOW THE 2ND FLOOR DECKING/SHEATHING TYPE | | | AND ATTACHMENTS - FBC WPB 107.1 | | | | | | 12) PLEASE SHOW THE STAIR HANDRAIL DETAILS - FBC | | | R311.7.8 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-03 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2023-04-03 08:33:00 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK - | | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | | ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON | | | THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL | | | SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT | | | OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A | | | HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | | APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE | | | PRODUCT APPROVAL. | | | | | | 2) THE EXTERIOR WALL CLADDING SYSTEM ON DRAWING A-5.00 | | | IS DIFFERENT THEN THE PRODUCT APPROVAL PROVIDED - | | | PLEASE SHOW ALL EXTERIOR WALL CLADDING COMPONETS SIZE, | | | THICKNESS AND ATTACHMENTS - FBC WPB 107.2.1 | | | | | | 3) PRODUCT APPROVAL FOR THE EXTERIOR WALL CLADDING WILL | | | NEED TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD - FBC WPB 107.3.4 | | | | | | 4) ALL PRODUCT APPROVALS THAT ARE NOT LISTED ON THE | | | DRAWINGS BY THE PRODUCT APPROVAL NUMBER WILL NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD FBC WPB 107.3.4 | | | | | | 5) PLEASE SHOW ROOF SHEATHING/ STEEL DECKING TYPE, | | | THICKNESS (STEEL DESIGNATION ETC.) AND ATTACHMENTS | | | (TYPE SIZE AND ON CENTER SPACING) - FBC WPB 107.2.1 | | | | | | 6) THE LOT GRADING PLAN NEEDS TO BE SIGNED AND SEALED | | | BY THE DESIGNER FBC WPB 107.1 | | | | | | 7) PLEASE SHOW THE WALL AND CEILING INSULATION TYPE AND | | | "R" VALUE ON THE DRAWINGS (TO MATCH THE ENERGY | | | CALCULATIONS) - FBC ENERGY CONSERVATION | | | | | | 8) PLEASE SHOW THE STAIR RISER AND TREAD DEPTH - FBC | | | R311.7.5.1 RISERS. FBC R311.7.5.2 TREADS. | | | | | | 9) PLEASE SHOW THE 2ND FLOOR DECKING/SHEATHING TYPE AND | | | ATTACHMENTS - FBC WPB 107.1 | | | | | | 10) PLEASE SHOW THE STAIR HANDRAIL DETAILS - FBC | | | R311.7.8 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2023-02-27 10:23:23 | NEW SFR ACCESSORY STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE | | | BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE | | | SITE PLAN OR PROVIDE A STORM WATER PLAN - FBC WPB | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT | | | SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES) | | | | | | 2) PLEASE PROVIDE A ROOFING SYSTEM PRODUCT APPROVAL - | | | IN THE PRODUCT APPROVAL FOR THE FLAT DECK - PLEASE | | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE ROOFING | | | PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON THE | | | PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL SIGNED | | | AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT OR | | | ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A | | | HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | | APPROVAL - SEE GENERAL LIMITATION NOTES ON THE PRODUCT | | | APPROVAL. | | | | | | 3) PLEASE SHOW EXTERIOR WALL CLADDING ATTACHMENT OR | | | PROVIDE A PRODUCT APPROVAL - FBC WPB 107.2.1 | | | | | | 4) PLEASE SHOW ROOF SHEATHING/ STEEL DECKING | | | ATTACHMENTS - FBC WPB 107.2.1 | | | | | | 5) THE SURVEY, DRAWING G-1 AND ALL OF THE STRUCTURAL | | | DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-07 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-07 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-02-16 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-02-16 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2023-02-16 08:59:00 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. REVIEW THE EGC OF PANEL 'B' 125A MCB POWERED FROM | | | PANEL 'A' 400A MLO. NEC 250.122 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-13 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-13 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-26 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-24 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-04-11 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-03-30 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-03-09 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-02-09 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-27 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2023-02-27 10:26:36 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-13 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-13 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-26 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-26 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2023-07-26 14:44:44 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-03 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2023-04-03 08:33:35 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2023-02-27 10:23:57 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-26 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-26 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-03 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-03 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2023-04-03 08:35:46 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE LOT GRADING PLAN DOES NOT SHOW AS DIGITALLY | | | SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-27 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2023-02-27 10:26:02 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE SURVEY, DRAWING G-1 AND ALL OF THE STRUCTURAL | | | DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | 2023-02-17 09:03:43 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
AVolcy |
Date |
2023-03-09 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-03-09 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2023-03-09 14:17:01 | THIS IS FOR AN ACCESSORY BUILDING. NO SECOND | | | KITCHEN/RANGE PERMITTED AS THIS PROPERTY IS LOCATED IN | | | SF7. | | | THE ACCESSORY BUILDING CANNOT CONTAIN A FULL KITCHEN W/ | | | RANGE & CANNOT BE RENTED OUT AS AN APARTMENT. | | | | | | | | | | | | **** REVIEWD BY **** | | | GAISHA (ANNE CLERISSE) VOLCY | | | PLANNER | | | [email protected] | | | |
|
|