| Plan Review Stops For Permit 22111224 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-27 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-04-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-12 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-12 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2023-04-12 13:16:24 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 REVISE SCOPE OF WORK ON PERMIT | | | APPLICATION TO INCLUDE INCREASE VALUE FOR ROOF-TO-WALL | | | MITIGATION. WORK TO BE PERFORMED BY A LICENSED | | | RESIDENTIAL CONTRACTOR, LICENSED BUILDING CONTRACTOR OR | | | LICENSED GENERAL CONTRACTOR. PROVIDE CONTRACTORS NAME & | | | LICENSE NUMBER ON PERMIT APPLICATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-08 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-08 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2023-03-08 10:23:58 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC EB 706.8.1 EXISTING ROOF-TO-WALL LOAD PATH | | | CONNECTION ANALYSIS SHOWING COMPLIANCE WITH WIND LOADS | | | IN TABLE 706.8.1 MUST BE SUBMITTED & VALIDATED BY A | | | LICENSED FLORIDA DESIGN PROFESSIONAL. SUBMITTED UNIFORM | | | MITIGATION FORM VERIFICATION INSPECTION FORM DOES NOT | | | VERIFY ROOF-TO-WALL CONNECTIONS AS PER SECTION 4H; NO | | | ATTIC ACCESS. REPORT LISTS ADDRESS AS 230 CLEMATIS | | | STREET. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-09 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-09 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2023-01-09 10:19:46 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL16732-R24 | | | (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF | | | WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT | | | CONSIDER USING FL5680-R36 (NON-HVHZ). | | | 2. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER TO UPDATE PRODUCT | | | APPROVAL TO THE CURRENT APPROVED PRODUCT APPROVAL/NOA | | | TO BE USED; INCLUDE UPDATED SYSTEM NUMBER TO BE USED. | | | 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | | WALL CONNECTIONS WILL BE IMPROVED. THE 2020 FBC EB | | | APPLIES TO EXISTING STRUCTURE WITH A SAWN LUMBER, WOOD | | | PLANK OR WOOD STRUCTURAL PANEL ROOF DECK IS REMOVED AND | | | REPLACED ON A BUILDING THAT IS LOCATED IN THE | | | WIND-BORNE DEBRIS REGION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-03 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-03 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2023-01-03 08:58:20 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL16732-R23 HAS BEEN | | | REVISED TO FL16732-R24. PLEASE PROVIDE THE FOLLOWING: | | | COVER PAGE, EVALUATION REPORT PAGES 1-6 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. | | | 2. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER TO UPDATE PRODUCT | | | APPROVAL TO THE CURRENT APPROVED VERSION | | | FL16732-R24; INCLUDE UPDATED PAGE NUMBER. | | | 3. FBC B 107.2.1. PLEASE CLARIFY; IF THIS ROOFING | | | PROJECT IS A RECOVER & EXISTING INSULATION IS TO REMAIN | | | PROVIDE A SIGNED AND SEALED MOISTURE REPORT PREPARED BY | | | A FLORIDA REGISTERED DESIGN PROFESSIONAL. | | | 4. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | | WALL CONNECTIONS WILL BE IMPROVED. | | | 5. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW | | | POSITIVE DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-27 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-04-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-12 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-03 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-08 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-02-28 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-09 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-04 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-03 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-30 |
Time |
06:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-04-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-12 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-12 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-08 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-08 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-09 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-09 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2023-01-09 10:22:17 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | PENDING REVISED ENHANCED NAILING CALCULATIONS | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-03 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-03 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2023-01-03 09:00:09 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | PENDING REVISED ENHANCED NAILING CALCULATIONS. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|