| Plan Review Stops For Permit 22111092 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-14 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-12 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-12 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2022-12-12 14:08:53 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | | | | 2. PROVIDE COVER SHEETS FOR THE OVERHEAD DOOR PRODUCT | | | APPROVALS. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR | | | PROPOSED EXTERIOR DOORS. | | | PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION | | | REPORT AND INSTALLATION INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4.PROVIDE A WINDOW AND DOOR FLASHING DETAIL PER | | | R703.4FLASHING. | | | APPROVED METAL FLASHING, VINYL FLASHING, SELF-ADHERED | | | MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING | | | SHALL BE APPLIED SHINGLE-FASHION OR IN ACCORDANCE WITH | | | THE MANUFACTURER???S INSTRUCTIONS. | | | | | | 5. CLARIFICATION REQUIRED. | | | NOA 19-0227.07 FOR TARIMATEC HOLLOW COMPOSITE DECK HAS | | | BEEN SUBMITTED FOR REVIEW. PLEASE IDENTIFY THE LOCATION | | | OF THIS PRODUCT ON THE PLANS. IF NOT USED, PLEASE | | | REMOVE IT FROM YOUR SUBMITTAL DOCUMENTS. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-18 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-18 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2022-12-01 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2022-12-01 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2022-12-01 16:09:13 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. SERVICE RECEPTACLE | | | A SERVICE RECEPTACLE NEEDS TO BE INSTALLED NEAR THE | | | EQUIPMENT FOR THIS PURPOSE. A 125-VOLT, 15- AND | | | 20-AMPERE RECEPTACLE FOR SERVICING AIR-CONDITIONING AND | | | REFRIGERATION EQUIPMENT IS REQUIRED TO BE LOCATED NOT | | | LESS THAN 7.5 M (25 FT) FROM, | | | AND ON THE SAME LEVEL AS, THE EQUIPMENT ITSELF. THE | | | RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION | | | FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS | | | APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING | | | OCCUPANCIES NEC 210.63 OR IRC | | | E3901.11 | | | | | | END OF COMMENTS | | | | | | THANK YOU, | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-03 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-03 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-25 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-25 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2023-01-25 10:23:25 | FBC-0202 RES. FUEL GAS REVIEW. | | | PERMIT- 22111092 | | | 1/25/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P1 & P2 ARE NOT DIGITALLY SIGNED AND SEALED | | | BY THE ARCHITECT OF RECORD- FL. STATUTE 481.221 AND | | | SEC. 61G1-16.005 FAC. | | | | | | 2) SHEET P2 GAS RISER: THE PVC SLEEVES SPECIFIED FOR | | | THE PE PIPING ARE NOT APPROVED. REFER TO SEC. | | | G2415.17.1 & G2415.17.2 FBC RES AND PROVIDE ANODELESS | | | RISERS OR SERVICE HEAD ADAPTER RISERS FOR THE PE | | | PIPING. PLESASE NOTE ANODELESS RISERS AND TRANSITION | | | FITTINGS BETWEEN THE PE AND METALLIC PIPING SHALL | | | CONFORM TO ASTM D2513 CAT. 1 OR ASTM F1973 - SECS. | | | G2415.17.1 & G2415.17.2. | | | | | | 3) SHEET P2: PLEASE CORRECT THE 11 IN.WC. MAX PRESSURE | | | FOR THE TAKAGI WATER HEATERS. THE MAN. SPECS INDICATE | | | MAX 10.5 IN. W.C.- SEC. G2448.1 FBC RES. | | | | | | 4) P2 GAS RISER: PLEASE CORRECT THE 2LB. SYSTEM LABEL | | | TO INDICATE A LOW PRESSURE LESS THAN 2PSI SYSTEM BASED | | | ON THE PIPE SIZING TABLE 402.4(2) SPECIFIED ON THE | | | DRAWING- SEC. G2413.3 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-13 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-13 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2023-01-13 10:03:06 | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 22111092 | | | 1/3/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P2: THE GAS RISER SHOWS A 2LB METER, OR 2PSI, | | | HOWEVER THE NEW GAS PIPING NOTES ON THE PLAN REFERENCE | | | TABLE 402.4(2) WHICH IS A SIZING TABLE FOR LOW PRESSURE | | | (LESS THAN 2PSI) SCHED. 40 METALLIC. USING THE SIZING | | | TABLE AND THE 72 FT. DEVELOPED LENGTH OF THE SYSTEM THE | | | 3/4-INCH BRANCH LINE FROM THE TEE TO THE 199 MBH WATER | | | HEATER SHALL BE INCREASED TO MINIMUM 1-INCH, AND THE | | | 3/4-INCH SUPPLYING THE 120 MBH WATER HEATER SHALL BE | | | INCREASED TO 1-INCH. THE 1/2-INCH PIPE TO THE DRYER IS | | | SIZED ADEQUATELY. | | | | | | 1) SHEET M-1: THE COMBUSTION AIR THROUGH THE WALL VENTS | | | ARE NOT DESIGNED IN COMPLIANCE WITH SEC. G2407.5.3.1 | | | (304.5.3.1) FBC RES WHICH STATES EACH OPENING SHALL BE | | | NOT LESS THAN 100 SQUARE INCHES. THE 6X18 INCH LOUVERS | | | ALLOW ONLY 75 % FREE AREA OR 81 SQ. INCHES- SEC. | | | G2407.10 (304.10). PLEASE INCREASE THE SIZE OF THE | | | LOUVERS TO MEET COMPLIANCE. PLEASE NOTE A MINIMUM 1000 | | | CU. FT. INDOOR AIR VOLUME IS REQUIRED FOR COMBUSTION | | | AIR FOR THE DRYER- 2ND REQUEST TO PROVIDE THE | | | CALCULATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-02 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-02 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2022-12-02 08:44:56 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 22111092 | | | 12/2/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P-2: PROVIDE COMBUSTION AIR PLANS AND | | | CALCULATIONS FOR THE RANGE, FIREPLACE, DRYER AND | | | TANKLESS WATER HEATER IN THE LAUNDRY ROOM- SECS G2407.1 | | | FBC RES. IT APPEARS THE STANDARD METHOD OF USING INDOOR | | | AIR FOR THE RANGE AND FIREPLACE CAN BE USED WHICH IS 50 | | | CUBIC FT. OF SPACE PER 1000 BTU, HOWEVER THE DRYER AND | | | THE WATER HEATER ARE IN CONFINED SPACE AND CANNOT USE | | | THIS METHOD- SEE SECS. G2407.6- G2407.11 FOR ALTERNATE | | | METHODS. IF THE WATER HEATER USES A DIRECT | | | VENT/COMBUSTION AIR INTAKE SYSTEM, REFER TO SECS. | | | G2427.2.1, G2427.8 ITEM 3. | | | | | | 2) P-2: PROVIDE VENTING PLANS FOR THE FIREPLACE AND | | | WATER HEATER- SEC. G2427.1 FBC RES. | | | A) FIREPLACE- REFER TO SECS. G2429.1.1- G2435.1 AND | | | DETAIL REQUIRED VENTING SYSTEM FOR THE FIREPLACE BASED | | | ON MANUFACTURER'S SPECIFICATIONS. PLEASE INCLUDE A | | | DIAGRAM INDICATING TYPE AND SIZE OF VENT FLUE, FLUE RUN | | | AND TERMINATION LOCATION. | | | B) WATER HEATER- REFER TO SEC. G2448.1 AND PROVIDE A | | | VENTING PLAN BASED ON MANUFACTURER'S SPECIFICATIONS. | | | PLEASE INCLUDE A DIAGRAM INDICATING TYPE AND SIZE OF | | | VENT FLUE, FLUE RUN AND TERMINATION LOCATION. | | | | | | 3) CORRECT THE ENERGY FORM R405 TO SHOW COMPLIANCE DATA | | | FOR A GAS-FIRED TANKLESS WATER HEATER, NOT ELECTRIC- | | | SEC. R101.5 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-01-24 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-01-24 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-12-08 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-12-08 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-06 |
Time |
05:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-02 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-26 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-24 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-01-24 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-01-12 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-12 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-30 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-01-26 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-01-24 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2023-01-26 11:19:59 | 1/26/23 NO IMPACT FEES DUE, SEE EMAIL UPLOADED AO | | 2023-01-24 09:21:06 | 1/24/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-12 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-12 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2022-12-12 10:50:22 | IMPACT FEES | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-06 |
Time |
05:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-06 |
Time |
05:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-26 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-26 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2023-01-26 13:37:59 | THE ARCHITECT MUST DIGITALLY SIGN THE MECHANICAL | | | DOCUMENTS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-13 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-13 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2023-01-13 08:15:54 | 2ND REVIEW FMC | | | PERMIT: 22111092 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS REVISION HAS A NEW POOL HOUSE. THIS WILL | | | REQUIRE A SEPARATE PERMIT. FBC 107.3.5 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING FOR THE NEW | | | POOL HOUSE. FEC R403.7.1 | | | | | | 3) SHOW THAT THE TRANSFER GRILLES FOR RETURN AIR FROM | | | THE BEDROOM AREA WILL MEET FRC M1602.3 EXCEPTION 1. 1.5 | | | TIMES THE CROSS SECTIONAL AREA OF THE SUPPLY DUCT | | | ENTERING THE ROOM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-01 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-01 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-03 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-03 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-25 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-25 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2023-01-25 10:24:50 | FBC- 2020 RES. PLUMBING REVIEW | | | PERMIT- 22111092 | | | 1/25/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P1 & P2 ARE NOT DIGITALLY SIGNED AND SEALED | | | BY THE ARCHITECT OF RECORD- FL. STATUTE 481.221 AND | | | SEC. 61G1-16.005 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-13 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-02 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-02 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2022-12-02 08:46:39 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22111092 | | | 12/1/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P-1 & P-2: THE PLANS SHOW TWO DWELLINGS ON | | | THE SAME LOT WHICH WILL REQUIRE WATER USERS TO INSTALL | | | A BACKFLOW PREVENTION ASSEMBLY AT THE POINT OF | | | DELIVERY. A REDUCED PRESSURE ZONE BACKFLOW DEVICE WILL | | | BE REQUIRED FOR THE WATER METER PER THE CITY OF WEST | | | PALM CROSS UTILITIES DEPARTMENT AND SECS. C, D, & E WPB | | | CROSS-CONNECTION MANUAL. | | | | | | PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR | | | SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE | | | BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB | | | AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL | | | BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT | | | PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT. | | | PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS | | | DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. | | | | | | 2) P1 & P2: PROVIDE A CLEANOUT AT THE JUNCTION OF THE | | | MAIN HOUSE BUILDING DRAIN AND SEWER- SEC. P3005.2.3 FBC | | | RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-14 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-12 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-12 |
Time |
06:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-03 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-03 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-25 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2023-01-25 10:11:55 | DIGITAL SIGNATURE REVIEW | | | PERMIT- 22111092 | | | 1/25/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS T1, M1, P1, & P2 ARE NOT DIGITALLY SIGNED AND | | | SEALED BY THE ARCHITECT OF RECORD- FL. STATUTE 481.221 | | | AND SEC. 61G1-16.005 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-14 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2023-01-13 08:18:33 | DIGITAL MECHANICAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-12 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-12 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2022-12-01 17:15:21 | MECHANICAL DIGITAL SIGNATURE APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-01-24 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-01-24 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-12-08 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-12-08 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|