| Plan Review Stops For Permit 22110947 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-07 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-07 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-27 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2023-02-27 14:27:34 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 3RD BUILDING REVIEW DENIED: | | | | | | FBC B 107.2/FBC R 301.2, PROVIDE WINDLOAD INFORMATION | | | INCLUDING WIND SPEED, RISK FACTOR AND EXPOSURE CATEGORY | | | ON PLAN SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-01 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-01 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2023-02-01 08:40:52 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC B 107.2/FBC R 301.2, PROVIDE WINDLOAD INFORMATION | | | INCLUDING WIND SPEED, RISK FACTOR AND EXPOSURE CATEGORY | | | ON PLAN SHEET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-29 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-29 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2022-12-29 14:39:32 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2/FBC R 301.2, PROVIDE WINDLOAD INFORMATION | | | INCLUDING WIND SPEED, RISK FACTOR AND EXPOSURE CATEGORY | | | ON PLAN SHEET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-02-08 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2023-02-08 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2023-02-08 |
Time |
07:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2023-01-19 |
Time |
22:02 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2023-01-19 |
Time |
19:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-12-15 |
Time |
23:00 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-12-15 |
Time |
22:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-03 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-01 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-12 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-01 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-27 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-01 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-01 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-29 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-13 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-13 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-12-19 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-12-19 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|