Plan Review Details - Permit 22110944
Plan Review Stops For Permit 22110944
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-12-20 Cont ID  
Sent By jgomez Date 2022-12-20 Time 14:39 Rev Time 0.00
Received By jgomez Date 2022-12-20 Time 14:28 Sent To  
Notes
2022-12-20 14:29:05APPROVED WITH PROVISO:
 NEED REMOVABLE CHILD BARRIER AROUND POOL COMPLYING WITH
 SEC. R4501.17.1.13 FBC-RESIDENTIAL FOR POOL FINAL
 INSPECTION. UNDER A SEPARATE FENCE-POOL BARRIER PERMIT.
  
  
 12-20-22 EMAIL FROM MICHAEL CURCIO:
 JULIO,
 WE ARE INSTALLING A CHILD BARRIER FENCE FOR FINAL
 INSPECTION. PLEASE ADVISE THAT THIS IS SUFFICIENT FOR
 THIS FENCE APPROVAL.
 SENT FROM MY IPHONE
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-12-19 Cont ID  
Sent By jgomez Date 2022-12-19 Time 11:14 Rev Time 0.00
Received By jgomez Date 2022-12-19 Time 10:18 Sent To  
Notes
2022-12-19 11:15:15RESIDENTIAL(R3), SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22110944
 530 36TH ST
  
 ORIGINAL COMMENT:
 1- SURVEY SHOWS DOUBLE GATES (10 FOOT OPENING). NEED TO
 PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW THE
 DOUBLE GATE COMPLIES WITH THE SELF-CLOSING AND
 SELF-LATCHING REQUIREMENTS OF SEC. R4501.17.1.8
 FBC-RESIDENTIAL.
  
 RESPONSE:
 PROPOSED DOUBLE GATES WAS REVIEWED WITH RICHARD
 GATHRIGHT (ASSISTANT BUILDING OFFICIAL) FOR BUILDING
 CODE COMPLIANCE. PROPOSED DON'T SHOW HOW THE TWO
 OPERABLE GATES COMPLY WITH THE SELF-CLOSING AND
 SELF-LOCKING REQUIREMENTS.
  
 R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By jgomez Date 2022-12-16 Time 16:57 Rev Time 0.00
Received By jgomez Date 2022-12-16 Time 16:57 Sent To  
Notes
2022-12-16 17:09:53RESIDENTIAL (R3), BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22110944
 530 36TH ST
  
 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS:
 1-SURVEY SHOWS DOUBLE GATES (10 FOOT OPENING).
 TYPICALLY DOUBLE GATES DON???T COMPLY WITH THE
 SELF-CLOSING AND SELF-LATCHING REQUIREMENTS OF SEC.
 R4501.17.1.8 FBC-RESIDENTIAL. NEED TO PROVIDE DETAILS
 AND SPECIFICATIONS SHOWING HOW THE DOUBLE GATES WILL
 COMPLY WITH THESE REQUIREMENTS. PROPOSED INSTALLATION
 WILL NEED BUILDING OFFICIAL APPROVAL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-12-16 Cont ID  
Sent By amhamilt Date 2022-12-16 Time 11:08 Rev Time 0.00
Received By amhamilt Date 2022-12-16 Time 11:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-20 Cont ID  
Sent By jgomez Date 2022-12-20 Time 15:24 Rev Time 0.00
Received By jgomez Date 2022-12-20 Time 14:28 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-19 Cont ID  
Sent By jgomez Date 2022-12-19 Time 11:15 Rev Time 0.00
Received By jgomez Date 2022-12-17 Time 19:13 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-16 Cont ID  
Sent By asangele Date 2022-12-16 Time 17:09 Rev Time 0.00
Received By jgomez Date 2022-11-22 Time 17:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-12-07 Cont ID  
Sent By asangele Date 2022-12-07 Time 17:10 Rev Time 0.00
Received By asangele Date 2022-12-07 Time 17:10 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved