Plan Review Details - Permit 22110877
Plan Review Stops For Permit 22110877
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 13:41 Rev Time 0.00
Received By cthroop Date 2023-07-11 Time 12:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-05-22 Cont ID  
Sent By cthroop Date 2023-05-22 Time 17:12 Rev Time 0.00
Received By cthroop Date 2023-05-22 Time 16:42 Sent To  
Notes
2023-05-22 17:12:56APPROVAL OF THE BUILDING REVIEW IS PENDING APPROVAL OF
 THE SIGNATURE REVIEW. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-05-04 Cont ID  
Sent By cthroop Date 2023-05-04 Time 10:52 Rev Time 0.00
Received By cthroop Date 2023-05-04 Time 06:53 Sent To  
Notes
2023-05-04 10:55:453RD BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1. CORRECT ADDRESS ON PLAN PAGES M1-01 AND M1-02.
 SHOULD BE 3802 GREENWOOD AVE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-03 Cont ID  
Sent By cthroop Date 2023-03-03 Time 07:20 Rev Time 0.00
Received By cthroop Date 2023-03-02 Time 12:32 Sent To  
Notes
2023-03-03 07:38:222ND BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 NOTICE:
 THIS REVIEW IS FOR THE REAR STRUCTURE (3802 GREENWOOD
 AVE.).
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) (CR-01
 NOT SUBMITTED FOR REVIEW)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. CORRECTED
  
 3. CORRECTED
  
 4. CORRECTED
  
 5.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT.
 DOORS. (CR-01 NOT SUBMITTED FOR REVIEW)
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NEW COMMENTS:
  
 6. ADDRESS ON ALL PLAN SHEETS IS INCORRECT. REAR
 STRUCTURE HAS BEEN ASSIGNED AN ADDRESS OF 3802
 GREENWOOD AVE. PLEASE CORRECT.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-26 Cont ID  
Sent By cthroop Date 2023-01-26 Time 16:10 Rev Time 0.00
Received By cthroop Date 2023-01-26 Time 13:03 Sent To  
Notes
2023-01-26 16:13:531ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 NOTICE:
 THIS REVIEW IS FOR THE REAR STRUCTURE (3802 GREENWOOD
 AVE.).
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: VALUE HAS BEEN ADJUSTED TO $45,000 BASED ON THE
 EXTENT OF DEMOLITION.
  
 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. IDENTIFY CEILING AND WALL INSULATION TYPE AND
 R-VALUE ON PLANS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 3. THERE ARE TWO DIFFERENT WINDOW AND DOOR SCHEDULES.
 SEE PLAN PAGES A1-01 AND A1-02. PLEASE CLARIFY?
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 4. PROVIDE SMOKE ALARMS.
 FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A
 BUILDING.
 SMOKE ALARMS
 R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314.
  
 5.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT.
 DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2023-05-18 Cont ID  
Sent By rperdomo Date 2023-05-18 Time 13:56 Rev Time 0.00
Received By rperdomo Date 2023-05-18 Time 13:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2023-04-20 Cont ID  
Sent By rperdomo Date 2023-04-20 Time 10:50 Rev Time 0.00
Received By rperdomo Date 2023-04-20 Time 09:24 Sent To  
Notes
2023-04-20 10:53:32FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. IN ORDER TO PROCEED WITH THE ELECTRICAL PLAN REVIEW
 , A DEMOLITION PERMIT APPLICATION FOR APPROVAL IS
 NEEDED.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-02-27 Cont ID  
Sent By rperdomo Date 2023-02-27 Time 13:43 Rev Time 0.00
Received By rperdomo Date 2023-02-27 Time 13:10 Sent To  
Notes
2023-02-27 13:43:37FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS 471/
 481
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By rperdomo Date 2023-01-03 Time 10:40 Rev Time 0.00
Received By rperdomo Date 2023-01-02 Time 12:17 Sent To  
Notes
2023-01-03 10:40:20FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. REVIEW THE ELECTRICAL PANEL SCHEDULE AND ELECTRICAL
 LOAD CALCULATON TO BE IN ACCORDANCE WITH NEC NEC 220,
 408.4(A) AND .
 A. SMOKE ALARMS (SMOKE DETECTION) AC POWER W/BATTERY
 BACK UP, SMOKE DETERCTOR REQUIRED TO BE INTERCONNECTED
 FBC R314.4
 B. SMALL APPLIANCE PER NEC 210.52 (B)
  
 2. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER
 NEC 440.14 OR IRC E4101.5
 DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN
 SIGHT FROM AND READILY ACCESSIBLE??? FROM THE
 AIR-CONDITIONING EQUIPMENT.
  
 3. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 5 Status P Date 2023-07-14 Cont ID  
Sent By amhamilt Date 2023-07-14 Time 16:32 Rev Time 0.00
Received By amhamilt Date 2023-07-14 Time 16:32 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2023-06-01 Cont ID  
Sent By amhamilt Date 2023-06-01 Time 14:59 Rev Time 0.00
Received By amhamilt Date 2023-06-01 Time 14:58 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2023-05-10 Cont ID  
Sent By amhamilt Date 2023-05-10 Time 10:55 Rev Time 0.00
Received By amhamilt Date 2023-05-10 Time 10:55 Sent To  
Notes
2023-05-10 10:55:58PLEASE REVISE ELEVATIONS AS DISCUSSED

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By amhamilt Date 2023-03-29 Time 16:24 Rev Time 0.00
Received By amhamilt Date 2023-03-29 Time 16:23 Sent To  
Notes
2023-03-29 16:24:32THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By amhamilt Date 2023-01-03 Time 12:08 Rev Time 0.00
Received By amhamilt Date 2023-01-03 Time 12:08 Sent To  
Notes
2023-01-03 12:08:53THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PROPOSED HORIZONTAL ROLLER WINDOWS ARE NOT
 ARCHITECTURALLY APPROPRIATE. PLEASE REVISE TO MATCH
 EXISTING OPENINGS AND WINDOWS.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-07-17 Cont ID  
Sent By aoliver Date 2023-07-17 Time 08:28 Rev Time 0.00
Received By aoliver Date 2023-06-20 Time 11:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-06-02 Cont ID  
Sent By aoliver Date 2023-06-02 Time 08:36 Rev Time 0.00
Received By aoliver Date 2023-05-12 Time 09:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-05-10 Cont ID  
Sent By lmarchan Date 2023-05-10 Time 14:58 Rev Time 0.00
Received By lmarchan Date 2023-04-17 Time 15:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-30 Cont ID  
Sent By aoliver Date 2023-03-30 Time 12:31 Rev Time 0.00
Received By aoliver Date 2023-02-24 Time 07:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-26 Cont ID  
Sent By cthroop Date 2023-01-26 Time 16:22 Rev Time 0.00
Received By cthroop Date 2022-12-30 Time 17:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2023-06-29 Cont ID  
Sent By cmontell Date 2023-06-29 Time 13:25 Rev Time 0.00
Received By cmontell Date 2023-06-29 Time 13:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2023-05-25 Cont ID  
Sent By hmoser Date 2023-05-25 Time 15:16 Rev Time 0.00
Received By hmoser Date 2023-05-25 Time 15:06 Sent To  
Notes
2023-05-25 15:16:04PLAN DENIED
 PLANS NOT SIGNED DIGITALLY.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2023-04-24 Cont ID  
Sent By medwards Date 2023-04-24 Time 13:20 Rev Time 0.00
Received By medwards Date 2023-04-24 Time 13:20 Sent To  
Notes
2023-04-24 13:23:34ADDRESS PREVIOUS COMMENT BELOW:
  
 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS
 471/481.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-02-27 Cont ID  
Sent By medwards Date 2023-02-27 Time 08:55 Rev Time 0.00
Received By medwards Date 2023-02-27 Time 08:55 Sent To  
Notes
2023-02-27 08:57:191ST CYCLE MECHANICAL REVIEW WAS NOT ADDRESSED IN THIS
 SUBMITTAL. PLEASE ADRESS THE FOLLOWING COMMENTS FROM
 1ST CYCLE REVIEW.
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS NEW SYSTEM. FRC R403.7.1
  
 2) A MECHANICAL SUB PERMIT WILL BE REQUIRED TO BE
 COMPLETED BY A MECHANICAL LICENSED CONTRACTOR.
  
 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS
 471/481.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By medwards Date 2023-01-03 Time 11:23 Rev Time 0.00
Received By medwards Date 2023-01-03 Time 11:23 Sent To  
Notes
2023-01-03 11:23:571ST REVIEW FMC
 PERMIT: 22110877
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS NEW SYSTEM. FRC R403.7.1
  
 2) A MECHANICAL SUB PERMIT WILL BE REQUIRED TO BE
 COMPLETED BY A MECHANICAL LICENSED CONTRACTOR.
  
 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS
 471/481.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-22 Cont ID  
Sent By rwbrown Date 2023-06-22 Time 12:42 Rev Time 0.00
Received By rwbrown Date 2023-06-22 Time 12:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-04-18 Cont ID  
Sent By rwbrown Date 2023-04-18 Time 06:49 Rev Time 0.00
Received By rwbrown Date 2023-04-18 Time 06:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-01-03 Cont ID  
Sent By rwbrown Date 2023-01-03 Time 08:33 Rev Time 0.00
Received By rwbrown Date 2023-01-03 Time 08:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-01-26 Cont ID  
Sent By cthroop Date 2023-01-26 Time 14:48 Rev Time 0.00
Received By cthroop Date 2023-01-26 Time 13:03 Sent To  
Notes
2023-01-26 14:48:45PROVISO ON PLAN PAGE A1-03: A SEPERATE ROOFING PERMIT
 IS REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 13:41 Rev Time 0.00
Received By cthroop Date 2023-07-11 Time 12:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-05-22 Cont ID  
Sent By cthroop Date 2023-05-22 Time 17:10 Rev Time 0.00
Received By cthroop Date 2023-05-22 Time 16:42 Sent To  
Notes
2023-05-22 17:12:204TH SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: PLAN PAGES - CS-00, S1-03, A1-02, A1-03, M1-01,
 M1-02 & P1-01.
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-05-04 Cont ID  
Sent By cthroop Date 2023-05-04 Time 10:51 Rev Time 0.00
Received By cthroop Date 2023-05-04 Time 06:53 Sent To  
Notes
2023-05-04 10:52:503RD SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-03-03 Cont ID  
Sent By cthroop Date 2023-03-03 Time 07:45 Rev Time 0.00
Received By cthroop Date 2023-03-02 Time 12:32 Sent To  
Notes
2023-03-03 07:46:272ND SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By medwards Date 2023-01-03 Time 11:24 Rev Time 0.00
Received By medwards Date 2023-01-03 Time 11:24 Sent To  
Notes
2023-01-03 11:25:21THE EOR MUST DIGITALLY SIGNAND SEAL ALL DRAWINGS. FS
 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 5 Status P Date 2023-07-14 Cont ID  
Sent By amhamilt Date 2023-07-14 Time 16:32 Rev Time 0.00
Received By amhamilt Date 2023-07-14 Time 16:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2023-06-01 Cont ID  
Sent By amhamilt Date 2023-06-01 Time 14:59 Rev Time 0.00
Received By amhamilt Date 2023-06-01 Time 14:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2023-05-10 Cont ID  
Sent By amhamilt Date 2023-05-10 Time 10:56 Rev Time 0.00
Received By amhamilt Date 2023-05-10 Time 10:56 Sent To  
Notes
2023-05-10 10:56:27PLEASE REVISE ELEVATIONS AS DISCUSSED

Review Stop Z ZONING
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By amhamilt Date 2023-03-29 Time 16:23 Rev Time 0.00
Received By amhamilt Date 2023-03-29 Time 16:23 Sent To  
Notes
2023-03-29 16:23:47THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By amhamilt Date 2023-01-03 Time 12:00 Rev Time 0.00
Received By amhamilt Date 2023-01-03 Time 12:00 Sent To  
Notes
2023-01-03 12:07:58THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 THE PROPOSED SCOPE OF DEMOLITION GREATLY EXCEEDS THE
 AMOUNT OF DEMOLITION PERMISSIBLE TO KEEP THE LEGAL
 NONCONFORMING SECOND UNIT ON SITE. PLEASE REVISE TO
 ONLY REPLACING THE MINIMUM AMOUNT OF DAMAGED MATERIAL
 TO REHABILITATE THE BUILDING.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  