| Plan Review Stops For Permit 22110877 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-11 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-11 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-22 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-22 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2023-05-22 17:12:56 | APPROVAL OF THE BUILDING REVIEW IS PENDING APPROVAL OF | | | THE SIGNATURE REVIEW. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-04 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-04 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2023-05-04 10:55:45 | 3RD BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. CORRECT ADDRESS ON PLAN PAGES M1-01 AND M1-02. | | | SHOULD BE 3802 GREENWOOD AVE. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-03-03 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-02 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2023-03-03 07:38:22 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | NOTICE: | | | THIS REVIEW IS FOR THE REAR STRUCTURE (3802 GREENWOOD | | | AVE.). | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) (CR-01 | | | NOT SUBMITTED FOR REVIEW) | | | R401.2COMPLIANCE. | | | SECTION R405 AND THE PROVISIONS OF SECTIONS R401 | | | THROUGH R404 LABELED MANDATORY. | | | | | | 2. CORRECTED | | | | | | 3. CORRECTED | | | | | | 4. CORRECTED | | | | | | 5.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA | | | FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT. | | | DOORS. (CR-01 NOT SUBMITTED FOR REVIEW) | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NEW COMMENTS: | | | | | | 6. ADDRESS ON ALL PLAN SHEETS IS INCORRECT. REAR | | | STRUCTURE HAS BEEN ASSIGNED AN ADDRESS OF 3802 | | | GREENWOOD AVE. PLEASE CORRECT. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-26 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-26 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2023-01-26 16:13:53 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | NOTICE: | | | THIS REVIEW IS FOR THE REAR STRUCTURE (3802 GREENWOOD | | | AVE.). | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: VALUE HAS BEEN ADJUSTED TO $45,000 BASED ON THE | | | EXTENT OF DEMOLITION. | | | | | | 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) | | | R401.2COMPLIANCE. | | | SECTION R405 AND THE PROVISIONS OF SECTIONS R401 | | | THROUGH R404 LABELED MANDATORY. | | | | | | 2. IDENTIFY CEILING AND WALL INSULATION TYPE AND | | | R-VALUE ON PLANS. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. THERE ARE TWO DIFFERENT WINDOW AND DOOR SCHEDULES. | | | SEE PLAN PAGES A1-01 AND A1-02. PLEASE CLARIFY? | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 4. PROVIDE SMOKE ALARMS. | | | FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A | | | BUILDING. | | | SMOKE ALARMS | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314. | | | | | | 5.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA | | | FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT. | | | DOORS. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-05-18 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-05-18 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-20 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-20 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2023-04-20 10:53:32 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. IN ORDER TO PROCEED WITH THE ELECTRICAL PLAN REVIEW | | | , A DEMOLITION PERMIT APPLICATION FOR APPROVAL IS | | | NEEDED. | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-02-27 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-02-27 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2023-02-27 13:43:37 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS 471/ | | | 481 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-01-03 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-01-02 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2023-01-03 10:40:20 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. REVIEW THE ELECTRICAL PANEL SCHEDULE AND ELECTRICAL | | | LOAD CALCULATON TO BE IN ACCORDANCE WITH NEC NEC 220, | | | 408.4(A) AND . | | | A. SMOKE ALARMS (SMOKE DETECTION) AC POWER W/BATTERY | | | BACK UP, SMOKE DETERCTOR REQUIRED TO BE INTERCONNECTED | | | FBC R314.4 | | | B. SMALL APPLIANCE PER NEC 210.52 (B) | | | | | | 2. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER | | | NEC 440.14 OR IRC E4101.5 | | | DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN | | | SIGHT FROM AND READILY ACCESSIBLE??? FROM THE | | | AIR-CONDITIONING EQUIPMENT. | | | | | | 3. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11 | | | THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION | | | FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS | | | APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING | | | OCCUPANCIES | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
5 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-07-14 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-07-14 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-06-01 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-06-01 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-05-10 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-05-10 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2023-05-10 10:55:58 | PLEASE REVISE ELEVATIONS AS DISCUSSED |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-29 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-29 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2023-03-29 16:24:32 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-01-03 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-01-03 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2023-01-03 12:08:53 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PROPOSED HORIZONTAL ROLLER WINDOWS ARE NOT | | | ARCHITECTURALLY APPROPRIATE. PLEASE REVISE TO MATCH | | | EXISTING OPENINGS AND WINDOWS. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-07-17 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-20 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-02 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-12 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-10 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-04-17 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-30 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-30 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-02-24 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-26 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-30 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-29 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-29 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-25 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-25 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2023-05-25 15:16:04 | PLAN DENIED | | | PLANS NOT SIGNED DIGITALLY. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-24 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-24 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2023-04-24 13:23:34 | ADDRESS PREVIOUS COMMENT BELOW: | | | | | | 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS | | | 471/481. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-27 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-27 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2023-02-27 08:57:19 | 1ST CYCLE MECHANICAL REVIEW WAS NOT ADDRESSED IN THIS | | | SUBMITTAL. PLEASE ADRESS THE FOLLOWING COMMENTS FROM | | | 1ST CYCLE REVIEW. | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS NEW SYSTEM. FRC R403.7.1 | | | | | | 2) A MECHANICAL SUB PERMIT WILL BE REQUIRED TO BE | | | COMPLETED BY A MECHANICAL LICENSED CONTRACTOR. | | | | | | 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS | | | 471/481. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-03 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-03 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2023-01-03 11:23:57 | 1ST REVIEW FMC | | | PERMIT: 22110877 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS NEW SYSTEM. FRC R403.7.1 | | | | | | 2) A MECHANICAL SUB PERMIT WILL BE REQUIRED TO BE | | | COMPLETED BY A MECHANICAL LICENSED CONTRACTOR. | | | | | | 3) THE EOR MUST DIGITALLY SIGN THE DRAWINGS. FS | | | 471/481. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-22 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-22 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-18 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-04-18 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-04-18 |
Time |
06:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-03 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-26 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-26 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2023-01-26 14:48:45 | PROVISO ON PLAN PAGE A1-03: A SEPERATE ROOFING PERMIT | | | IS REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-11 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-11 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-22 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-22 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2023-05-22 17:12:20 | 4TH SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: PLAN PAGES - CS-00, S1-03, A1-02, A1-03, M1-01, | | | M1-02 & P1-01. | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-04 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-04 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2023-05-04 10:52:50 | 3RD SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-03-03 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-02 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2023-03-03 07:46:27 | 2ND SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-03 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-03 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2023-01-03 11:25:21 | THE EOR MUST DIGITALLY SIGNAND SEAL ALL DRAWINGS. FS | | | 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-07-14 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-07-14 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-06-01 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-06-01 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-05-10 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-05-10 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2023-05-10 10:56:27 | PLEASE REVISE ELEVATIONS AS DISCUSSED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-29 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-29 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2023-03-29 16:23:47 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-01-03 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-01-03 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2023-01-03 12:07:58 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | THE PROPOSED SCOPE OF DEMOLITION GREATLY EXCEEDS THE | | | AMOUNT OF DEMOLITION PERMISSIBLE TO KEEP THE LEGAL | | | NONCONFORMING SECOND UNIT ON SITE. PLEASE REVISE TO | | | ONLY REPLACING THE MINIMUM AMOUNT OF DAMAGED MATERIAL | | | TO REHABILITATE THE BUILDING. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|