Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-12-14 Cont ID  
Sent By jwitmer Date 2022-12-14 Time 12:58 Rev Time 0.00
Received By jwitmer Date 2022-12-14 Time 12:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-01-03 Cont ID  
Sent By jwitmer Date 2023-01-03 Time 07:36 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-14 Cont ID  
Sent By jwitmer Date 2022-12-14 Time 13:55 Rev Time 0.00
Received By jwitmer Date 2022-12-14 Time 12:56 Sent To  
Notes
2022-12-14 13:55:27WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22110868
 ADD: 380 COLUMBIA DR. # 100
 CONT: VERTEX CONSTRUCTION INC.
 TEL: 561-619-7722
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. DEC. 14TH/2022
 ACTION: DENIED
 1) FINISH FLOOR PLAN:
  
 1A) EXISTING ENLARGED RESTROOM AND NEW RESTROOM 103
 BOTH SHOW THE WALL FINISH P-1 BUILDING STANDARD WALL
 PAINT.
 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT
 IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON
 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS
 EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD,
 NON-ABSORBENT SURFACE
  
 1B) 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS
 A BASE FOR WALL TILE IN ACCORDANCE WITH
 MANUFACTURER???S RECOMMENDATIONS. WATER RESISTANT
 GYPSUM (MR BOARD) SHALL NOT BE USED FOR SHOWER & TUB
 ENCLOSURES BUT CAN BE USED FOR BACKING BOARD FOR A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE???S RECOMMENDATIONS.
  
 1C) THE JANITOR???S CLOSET HAS A TAG FOR FRP BUT THIS
 DESIGNATION IS NOT FOUND IN THE WALL FINISH SCHEDULE.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1. CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 1D) THE FLOOR PLAN DOES NOT SHOW A DRINKING FOUNTAINS.
 BUILDING CODE OCCUPANT LOAD TAKEN AT 150 SQ FT/
 OCCUPANT OR 2825/150= 19 OCCUPANTS. PLUMBING CODE TABLE
 410 STILL TAKES 100 SQ FT/ OCCUPANT OR 2895/ 10=29
 OCCUPANTS, REQUIRES DRINKING FOUNTAINS. PLEASE SHOW
 COMPLIANCE WITH 2020 FBC-ACCESSIBILITY CODE.
  
 1D)(1) 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
  
 1D)(2) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS
 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES
 AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT
 PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE
 CIRCULATION PATH.
  
 1D)(2) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 1D)(3) SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND FOR WHEELCHAIR BOUND INDIVIDUALS.
 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
 BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-11-28 Cont ID  
Sent By mpeterso Date 2022-11-28 Time 11:44 Rev Time 0.00
Received By mpeterso Date 2022-11-28 Time 11:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-11-22 Cont ID  
Sent By cwalker Date 2022-11-22 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-03 Cont ID  
Sent By jwitmer Date 2023-01-03 Time 07:36 Rev Time 0.00
Received By jwitmer Date 2022-12-22 Time 14:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-12-14 Time   Rev Time 0.00
Received By cdecoeur Date 2022-11-21 Time 06:52 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jwitmer Date 2022-12-14 Time 12:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-11-30 Cont ID  
Sent By medwards Date 2022-11-30 Time 15:54 Rev Time 0.00
Received By medwards Date 2022-11-30 Time 15:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-12-28 Cont ID  
Sent By rwbrown Date 2022-12-28 Time 06:15 Rev Time 0.00
Received By rwbrown Date 2022-12-28 Time 06:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-11-30 Cont ID  
Sent By rwbrown Date 2022-11-30 Time 14:15 Rev Time 0.00
Received By rwbrown Date 2022-11-30 Time 14:01 Sent To  
Notes
2022-11-30 15:39:221ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FAC - 202.3 - PLEASE SHOW YOUR ADA MEASUREMENTS
 INCLUDING CLEAR FLOOR SPACE FOR PLUMBING ELEMENTS,
 TURNING RADIUS', APPROACHES, ETC.
  
 2. 2020 FPC 607.1.1 - HOT WATER DELIVERY - PER THIS
 SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT
 SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER
 DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE.
 THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE
 INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1.
 THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC
 HANDWASHING PROTECTION FOR TEMPERED WATER. PLEASE ADD A
 WATER HEATER DETAIL FOR THE MOP SINK THAT SHOWS A 1017
 MIXING DEVICE.
  
 3. 2017 WPB AMENDS 107.3.5.1.3 - IN MODIFYING THE
 EXISTING BATHROOM AND MOVING THE LAVATORY, YOU'LL NEED
 TO INCLUDE A RISER FOR THAT BATHROOM AS WELL. PLEASE
 NOT WHEN DESIGNING IT, THAT THE SINK ON THE OTHER SIDE
 OF THE WALL CANNOT BE INCLUDED IN THE VENT FOR THE
 WATER CLOSET AS IT IS NOT A BATHROOM GROUP FIXTURE. IT
 WOULD NEED TO DISCHARGE DOWNSTREAM OF THE WET VENT
 SYSTEM PER 2020 FPC 912.1.
  
 4. 2020 FPC 403.1 - PROVIDE HIGH AND LOW DRINKING
 FOUNTAINS PER 410.3
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-01-03 Cont ID  
Sent By jwitmer Date 2023-01-03 Time 07:36 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-30 Cont ID  
Sent By medwards Date 2022-11-30 Time 15:54 Rev Time 0.00
Received By medwards Date 2022-11-30 Time 15:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2022-12-06 Cont ID  
Sent By kdefranc Date 2022-12-06 Time 19:30 Rev Time 0.00
Received By kdefranc Date 2022-12-06 Time 19:29 Sent To  
Notes
***NONE***