Plan Review Details - Permit 22110755
Plan Review Stops For Permit 22110755
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-02-24 Cont ID  
Sent By pvalenti Date 2023-02-24 Time 08:15 Rev Time 0.00
Received By pvalenti Date 2023-02-23 Time 15:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-01-19 Cont ID  
Sent By pvalenti Date 2023-01-19 Time 16:26 Rev Time 0.00
Received By pvalenti Date 2023-01-19 Time 16:06 Sent To  
Notes
2023-01-19 16:32:04PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW FAILED:
  
 FBC B 107.2.1, COMMENTS ARE NOT CLEAR AS TO SELECTED
 APPROVED ADHESIVE TO BE USED(AH160?). PLEASE PROVIDE A
 RESPONSE LETTER TO SHOW SPECIFICALLY WHICH ADHESIVE IS
 TO BE USED ALONG WITH APPROVED CALCULATIONS OR REMOVE
 THE ADHESIVE DETAILS AND USE THE MECHANICAL ANCHORING
 OPTION AS SHOWN ON PLAN SHEET S-2 FOR ALL ANCHORING
 ATTACHMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-28 Cont ID  
Sent By pvalenti Date 2022-12-28 Time 13:04 Rev Time 0.00
Received By pvalenti Date 2022-12-28 Time 10:27 Sent To  
Notes
2022-12-28 13:26:50PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, CLARIFY ON PLAN SHEET S-1, WHICH
 ROOF SECTION IS FLAT AND WHICH ROOF SECTION IS PITCHED.
 2.) FBC B 107.2.1, CLARIFY ON PLAN SHEET S-2, AT WHICH
 AREA OF ROOF IS THE LAG BOLT ANCHORING TO BE USED.
 3.) FBC B 107.2.1, CLARIFY ON PLAN SHEET S-3, AT WHICH
 AREA OF ROOF IS THE FOAM ADHERED SYSTEM TO BE USED. IF
 THIS ADHESIVE SYSTEM IS TO BE USED, PLEASE SELECT THE
 PRODUCT TO BE USED AND REMOVE THE PRODUCT FROM PLANS
 THAT IS NOT TO BE USED (TILE FOAM POLSET AH160 OR DAP
 TOUCH N SEAL STORM BOND).
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-02-08 Cont ID  
Sent By mpeterso Date 2023-02-08 Time 10:19 Rev Time 0.00
Received By mpeterso Date 2023-02-08 Time 10:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-12-09 Cont ID  
Sent By mpeterso Date 2022-12-09 Time 16:13 Rev Time 0.00
Received By mpeterso Date 2022-12-09 Time 16:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-02-24 Cont ID  
Sent By pvalenti Date 2023-02-24 Time 08:16 Rev Time 0.00
Received By pvalenti Date 2023-02-02 Time 12:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-19 Cont ID  
Sent By pvalenti Date 2023-01-19 Time 16:32 Rev Time 0.00
Received By pvalenti Date 2023-01-04 Time 13:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-28 Cont ID  
Sent By pvalenti Date 2022-12-28 Time 13:27 Rev Time 0.00
Received By pvalenti Date 2022-11-21 Time 07:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-02-08 Cont ID  
Sent By mpeterso Date 2023-02-08 Time 10:26 Rev Time 0.00
Received By mpeterso Date 2023-02-08 Time 10:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-01-19 Cont ID  
Sent By pvalenti Date 2023-01-19 Time 16:32 Rev Time 0.00
Received By pvalenti Date 2023-01-19 Time 16:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-12-09 Cont ID  
Sent By mpeterso Date 2022-12-09 Time 16:13 Rev Time 0.00
Received By mpeterso Date 2022-12-09 Time 16:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-02-10 Cont ID  
Sent By vbroglia Date 2023-02-10 Time 16:33 Rev Time 0.00
Received By vbroglia Date 2023-02-10 Time 16:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-12-14 Cont ID  
Sent By vbroglia Date 2022-12-14 Time 15:33 Rev Time 0.00
Received By vbroglia Date 2022-12-14 Time 15:33 Sent To  
Notes
***NONE***