Plan Review Details - Permit 22110661
| Plan Review Stops For Permit 22110661 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-14 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-14 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2023-04-14 10:10:25 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT A SURVEY. SHOW THE LOCATION OF THE GENERATOR | | | AND SET BACKS FROM PROPERTY LINES AND BUILDINGS. FBC | | | 107.2.1 | | | | | | 2) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. FBC-R303.5.1 | | | INTAKE OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR | | | INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET | | | (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, | | | SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, | | | ALLEYS, PARKING LOTS AND LOADING DOCKS. THIS SHOULD BE | | | NOTED ON THE SURVEY. | | | | | | 3) SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE | | | PROPOSED 24 KW GENERATOR. FBC 107.2.1 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-03 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-05-03 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-05-03 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-04-18 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-18 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-18 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2023-04-18 09:32:49 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE MANUFACTURE' S SPECIFICATIONS FOR THE | | | PROPOSED 24 KW GENERATOR. FBC 107.3.5 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-04 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-04-21 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-19 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-04-07 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-14 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-14 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-04-28 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-17 |
|
|
Cont ID |
|
| Sent By |
ASangele |
Date |
2023-04-17 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-04-17 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2023-04-17 18:34:29 | FAILED | | | 4/17/2023 | | | | | | PLEASE PROVIDE A SURVEY WITH APPLICATION AND INDATE | | | WHERE THE GENERATOR WILL BE LOCATED. | | | | | | ARTICLE X SECTION 94-305 | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK. | | | | | | | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] |
|
|
|