| Plan Review Stops For Permit 22110628 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-03-29 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-03-29 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2023-03-29 12:47:22 | ADDRESS FOR THE PROJECT HAS BEEN AGREED AS 2484 | | | PINEWOOD AVE UPDATED PERMIT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-02-28 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2023-02-28 15:16:04 | AN ADDRESS NEEDS TO BE ASSIGNED TO THIS PROJECT, | | | 2.12.22 I EMAIL BERNARDO VANEGAS THE FOLLOWING | | | ADDRESSES FOR THE PROJECT: 615 23RD ST (IF BROADWAY IS | | | GOING TO BE EXTENDED THEN THIS SHOULD BE CHANGED TO A | | | BROADWAY ADDRESS) | | | 629 23RD ST | | | 635 23RD ST | | | 637 23RD ST | | | 641 23RD ST | | | | | | 590 NORTHWOOD RD | | | 620 NORTHWOOD RD | | | 634 NORTHWOOD RD | | | 650 NORTHWOOD RD | | | 662 NORTHWOOD RD | | | 672 NORTHWOOD RD | | | | | | 585 NORTHWOOD RD | | | 645 NORTHWOOD RD | | | 659 NORTHWOOD RD | | | 679 NORTHWOOD RD | | | | | | 580 24TH ST | | | 636 24TH ST | | | 654 24TH ST | | | 680 24TH ST | | | | | | 641 24TH ST | | | 655 24TH ST | | | 667 24TH ST | | | 681 24TH ST | | | | | | 612 25TH ST | | | 624 25TH ST | | | | | | 2461 PINEWOOD AVE | | | 2471 PINEWOOD AVE | | | 2515 PINEWOOD AVE | | | 2525 PINEWOOD AVE | | | 2541 PINEWOOD AVE | | | 2555 PINEWOOD AVE | | | 2575 PINEWOOD AVE | | | | | | 2462 PINEWOOD AVE | | | 2464 PINEWOOD AVE | | | 2476 PINEWOOD AVE | | | 2484 PINEWOOD AVE | | | 2556 PINEWOOD AVE | | | 2576 PINEWOOD AVE | | | | | | 2419 BROADWAY | | | 2435 BROADWAY | | | 2451 BROADWAY | | | 2471 BROADWAY | | | 2527 BROADWAY | | | 2541 BROADWAY | | | 2561 BROADWAY | | | 2571 BROADWAY | | | | | | 2426 BROADWAY | | | 2436 BROADWAY | | | 2458 BROADWAY | | | 2470 BROADWAY | | | | | | THEN BRYAN BENHAMOU WAS SENT THE LIST OF PROPOSED | | | ADDRESSES ON 12.16.22, THANK ME FOR MY EMAIL STATED | | | THAT THEY WOULD DISCUSS INTERNALLY AND HAVE NOT HEARD | | | FROM ANYONE. PLEASE CONTACT [email protected] OR | | | CALL 561-805-6659 TO DISCUSS ADDRESSING. FOR THE | | | FOUNDATION PERMIT WE ONLY NEED TO START WITH THE | | | PRIMARY ADDRESS FOR THE PROJECT. ALSO THE PARCEL WILL | | | NEED TO BE REPLATTED SO THAT THERE IS ONLY ONE PARCEL, | | | WHERE ARE YOU IN THAT STAGE, PLEASE EMAIL ME THE | | | PRELIMINARY PCN LETTER FROM THE PROPERTY APPRAISERS. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
2023-05-22 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
2023-05-22 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2023-05-22 11:28:23 | MISSING ART ASSESSMENT APPLICATION AND ESCROW OF FUNDS | | | OR CONTRIBUTION INTO THE FUNDS. | | | | | | ALLL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | | EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $500,000.00. ALL BUILDINGS | | | WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED | | | CUMULATIVELY TOWARDS THIS PUBLIC ART REQUIREMENT, EVEN | | | IF THE BUILDINGS ARE PERMITTED SEPARATELY OR DEVELOPED | | | IN PHASES | | | | | | OPTION 1: INSTALL AND ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | | | | IF INSTALLING ARTWORK OPTION 1, SUBMIT AN ART | | | ASSESSMENT APPLICATION, WHICH INCLUDES ALL DOCUMENTS | | | INCLUDING EVIDENCE OF ESCROW. THE ART APPLICATION SHALL | | | BE SUBMITTED WITH THE APPLICATION FOR A BUILDING | | | PERMIT. | | | | | | OF NOTE ARTWORK SHALL BE CLEARLY DEMONSTRATED ON ALL | | | SITE-PLANS SUBMITTED FOR CITY APPROVALS. | | | | | | ART ASSESSMENT IS DUE NOW ESCROW OR DIRECT DEPOSIT DUE | | | NOW. | | | | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-25 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-25 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2023-07-25 14:52:05 | FOUNDATION AND STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE ADDED DRAWING A301.5 SHOWS EV CHARGING STATIONS | | | - PLEASE SHOW THAT AT LEAST 1 OF THE CHARGING STATIONS | | | IS AN ACCESSIBLE PARKING SPACE, ACCESS AISLE, SIGNAGE | | | ETC. PER FBC A 502 | | | FBC 406.1.7 ELECTRIC VEHICLE CHARGING STATIONS. | | | ACCESSIBILITY TO ELECTRIC VEHICLE CHARGING STATIONS | | | SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 11. | | | | | | 2) PLEASE SHOW THE STORM WATER DRAINAGE - SITE OR CIVIL | | | PLAN SHOULD SHOW ALL OF THE FOLLOWING FBC WPB 107.2.5 | | | SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH | | | THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A | | | SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW | | | CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-11 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-11 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2023-05-11 14:15:30 | FOUNDATION AND STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER | | | THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | A) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | | | 2) PLEASE SHOW THE BUILDING SETBACKS FROM THE PROPERTY | | | LINES AND OTHER BUILDINGS. THE SITE PLAN OR CIVIL PLAN | | | NEEDS TO SHOW ALL OF THE FOLLOWING INFORMATION - FBC | | | WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | | SURVEY. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-20 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-16 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2023-03-20 09:38:06 | FOUNDATION AND STRUCTURE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING S-1.0A SHOWS THE 2014 FBC - SHOULD BE 2020 | | | FBC | | | | | | 2) PLEASE PROVIDE THE LIFE SAFETY PLANS FOR EACH FLOOR. | | | | | | 3) EACH SEPARATE BUILDING REQUIRES A SEPARATE PERMIT | | | WITH ITS OWN PLANS - PLEASE REMOVE THE DRAWINGS IN THIS | | | PERMIT FOR BUILDINGS "B" AND "C" | | | | | | 4) PLEASE SHOW THE ACCESSIBLE VAN PARKING HEIGHT AND | | | LOCATION - 502.5 VERTICAL CLEARANCE. | | | PARKING SPACES FOR VANS AND ACCESS AISLES AND VEHICULAR | | | ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE | | | OF 98 INCHES (2490 MM) MINIMUM. | | | | | | 5) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER | | | THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | A) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | | | 6) DRAWINGS S-8.1, S-8.2, S-8.3, S-8.4, S-8.5, S-8.6 DO | | | NOT SHOW THE WIND PRESSURES AS STATED ON THOSE | | | DRAWINGS. | | | | | | 7) PLEASE PROVIDE A STORM WATER DRAINAGE PLAN. FBC WPB | | | 107.2.5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
|
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-26 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-26 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2023-07-26 14:52:54 | EMAILED THE APPLICANT TO PROVIDE A MISSING NARRITIVE | | | RESPONSE. THEY EMAILED BACK WITH A RESPONSE. I WILL | | | CONTINUE THE REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-05-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-17 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-17 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2023-05-17 16:00:41 | ELECTRIC REVIEW FAILED 2ND CYCLE | | | | | | 1) SUBMITTAL DOES NOT INCLUDE ALL DRAWINGS INDICATED ON | | | PLAN INDEX SHEET CS001. MISSING DRAWINGS INCLUDE ALL | | | ELECTRICAL DRAWINGS E202.1 -E202.8 . THESE DRAWINGS ARE | | | ALSO REFERENCED ON SHEET E200. | | | | | | 2) PLEASE PROVIDE SHEETS LABELED E200.1 AND E200.3 | | | (SECTIONS OF BUILDING A). FBC 107.2 | | | | | | 3) SHEET E501B, CORRECTLY LABELED, ELECTRICAL RISER | | | DIAGRAM BUILDING A, AND IS AGAIN LABELED BELOW THE | | | DIAGRAM AS BUILDING B. IN ADDITION THE SUBMITTAL NAME | | | IS CALLED OUT INCORRECTLY AS RISER B. PLEASE CORRECT AS | | | APPLICABLE. FBC 107.2 | | | | | | 4) PLEASE CORRECT LABELING FOR SHEET E502A SUBMITTAL | | | NAME INDICATES RISE INSTEAD OF CORRECTLY NAMING | | | ELECTRIC CALCS AND RISER NOTES | | | | | | 5) PLEASE ENSURE ALL SHEET NAMES ARE CORRECTLY LABELED | | | ON SHEETS AND SUBMITTAL NAMING. FBC 107.2 | | | | | | 6) PLEASE PROVIDE ELECTRIC RISER DIAGRAM FOR BUILDING | | | C. FBC 107.2 | | | | | | 7) PLEASE PROVIDE INDICATIONS THAT ALL OVERCURRENT | | | PROTECTION RATED 1200 AMPS AND ABOVE CONTAIN ARC ENERGY | | | REDUCTION METHOD IN ACCORDANCE WITH NEC 240.87 (A) AND | | | (B) | | | | | | 8) PLEASE PROVIDE INDICATIONS THAT ALL FEEDER | | | DISCONNECTS RATED 1000 AMPS AND ABOVE, FOR SYSTEMS OF | | | MORE THAN 150 VOLTS TO GROUND ARE PROVIDED WITH GROUND | | | FAULT PROTECTION. NEC 215.10 NEC | | | | | | 9) PLEASE PROVIDE FLOOR PLANS FOR BOTH ELECTRIC ROOMS | | | IN BUILDING A, B AND C LOCATING ALL ELECTRICAL | | | EQUIPMENT AND INDICATING ALL CLEARANCES REQUIRED IN | | | ACCORDANCE WITH NEC 110.26 ARE MET. FBC 107.2 | | | | | | 10) PLEASE PROVIDE FLOOR PLANS FOR FIRE PUMP ROOM IN | | | BUILDING A LOCATING ALL EQUIPMENT AND INDICATING ALL | | | REQUIREMENTS OF NEC ARTICLE 695 ARE MET. FBC 107.2 | | | | | | 11) PLEASE PROVIDE FLOOR PLANS FOR GENERATOR ROOM IN | | | BUILDING A LOCATING ALL EQUIPMENT AND INDICATING ALL | | | REQUIREMENTS OF NEC ARTICLE 700, 445 AND CLEARANCES IN | | | ACCORDANCE TO NEC 110.26. FBC 107.2 | | | | | | 12) PLEASE PROVIDE A NOTE STATING ALL LOW VOLTAGE | | | WIRING SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE ALARM, | | | VOICE, DATA TELEPHONE, TV, SATELLITE, SECURITY AND BDA, | | | DAS, CELL PHONE ENHANCEMENT SYSTEMS REQUIRE A SEPARATE | | | PERMIT. IN ADDITION, SITE LIGHTING AND SIGNS WILL BE | | | REQUIRED TO BE SEPARATE PERMITS | | | | | | 13) PLEASE PROVIDE A FEEDER SCHEDULE FOR ALL RISER | | | DIAGRAMS. NEC 215.5 | | | | | | 14) SUBMITTAL CONTAINS SOME ELECTRIC SHEETS THAT HAVE A | | | RED X ON THEM. IF THESE SHEETS ARE NOT INCLUDED WITH | | | THE SUBMITTAL PLEASE HAVE THEM REMOVED. FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-07 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-06 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2023-03-07 10:22:12 | ELECTRIC REVIEW FAILED | | | | | | 1) PLEASE DETAIL ON SHEET E400A COMPLIANCE WITH NEC | | | 695.14(E), PROTECTION OF FIRE PUMP GENERATOR CONTROL | | | WIRING | | | 2) PLEASE DETAIL COMPLIANCE WITH NEC 230.95, GROUND | | | FAULT PROTECTION FOR 480V/2000A MDP-RS AND 480/2500A | | | MDP-RN | | | 3) PLEASE DETAIL COMPLIANCE WITH NEC 695.39(B) FOR | | | BUILDINGS B AND C, ALTERNATE SOURCE OF POWER, AS THE | | | AHJ DOES NOT REGARD FPL UTILITY POWER AS A RELIABLE | | | SOURCE. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
cseifer |
Date |
2023-07-18 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
cseifer |
Date |
2023-07-18 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-05-09 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-06-07 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-02-21 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2023-02-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-21 11:24:45 | UNDER FORMAL ENGINEERING SUBMITTAL REVIEW (E22120042). |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-17 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-08 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-02-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-22 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2023-02-22 12:37:12 | FIRE COMMENT: | | | | | | ANY FIRE LINE UNDERGROUND THAT MAY BE INSTALLED UNDER | | | THIS PERMIT SHALL BE SUBMITTED UNDER SEPARATE PERMIT & | | | SHOP | | | DRAWING PER NFPA 24 AND MANUFACTURES SPECIFICATIONS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-14 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-05 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-05 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-04-04 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-16 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-20 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-20 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2023-03-20 09:38:50 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-19 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-19 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2023-07-19 15:02:46 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 22110628 | | | 7/19/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE NOTE A COMPLETE | | | REVIEW OF THE PLUMBING SYSTEMS WAS NOT PERFORMED UNDER | | | THIS FOUNDATION PERMIT, AND ADDITIONAL COMMENTS | | | IMPACTING THE UNDERGROUND PIPING SYSTEMS MAY OCCUR | | | UNDER THE MAIN PERMIT REVIEW. | | | | | | 1) SHEET P200.1, P200.3, P200.5, P402A: BASED ON THE | | | SCHIER SI & GI SPECIFICATIONS SHOWN ON THE DERM SHEETS | | | THE GREASE INTERCEPTOR INLET AND OUTLET PIPINGS SHALL | | | BE 4-INCH- SEC. 1003.3.5.1 FBC P. THE PLANS SHOW 3-INCH | | | FOR FOG SYSTEMS #1 & 3. | | | | | | 2) BUILDING A GROUND FLOOR SHEETS P200.1, .2, .3, .4, | | | .5, .6: AS PREVIOUSLY REQUESTED IN THE 1ST AND 2ND | | | REVIEWS PLEASE SHOW THE FOLLOWING ITEMS. | | | | | | A) DFU'S FOR SANITARY PIPING AT RISERS, BRANCHES AND | | | MAIN BUILDING DRAINS- TABLE 710.1(1) FBC P. | | | | | | B) STORM DRAINAGE FLOW IN GPM FOR EACH STORM DRAIN | | | BRANCH AND MAIN- TABLE 1106.2 FBC P. | | | | | | C) AC CONDENSATE AND WATER HEATER DISCHARGE VERTICAL | | | RISER LOCATIONS AND HORIZONTAL UNDERGROUND PIPING RUNS | | | AND TERMINATION LOCATIONS- SECS. 314.2.1 & 504.7.1, | | | 504.7.2 FBC P. | | | | | | D) EMERGENCY FLOOR DRAIN LOCATIONS AND TRAP SEAL | | | PROTECTION METHOD- SEC. 1002.4 FBC P. | | | | | | 3) 2ND REQUEST FOR GREASE INTERCEPTOR PERMIT | | | APPLICATIONS. | | | | | | PLEASE NOTE DUE TO A CHANGE IN PROCESS, THE GREASE | | | INTERCEPTOR PERMITS ARE REQUIRED TO BE SUBMITTED PRIOR | | | TO APPROVAL OF THIS PLUMBING REVIEW. YOU CAN SUBMIT | | | APPLICATIONS TBD (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected]. YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATIONS ARE REQUIRED AT THIS TIME. WE RECOMMEND | | | THAT YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. | | | AFTER YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA | | | EMAIL AND I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | | | A) SHEET P402A: 2ND REQUEST TO SHOW VENTING FOR THE | | | INTERCEPTORS- SEC. 1003.9 FBC P. | | | | | | B) P9.00- P905 DERM SHEETS: 2ND REQUEST TO PROVIDE | | | HEAVY DUTY LIDS FOR THE INTERCEPTOR CLEANOUTS. PLEASE | | | PROVIDE MANUFACTURER AND MODEL NUMBER OF THE LIDS- SEC. | | | 305.7 FBC P. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-10 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-09 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2023-05-10 17:05:24 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22110628 | | | 5/10/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IT APPEARS MANY OF THE KEY PLUMBING DRAWINGS | | | INCLUDING P200.1- P.200.6 WHICH ARE THE UNDERGROUND | | | DRAINAGE PIPING PLANS FOR BUILDING A HAVE NOT BEEN | | | CORRECTED AND RESUBMITTED (SEE 1ST REVIEW COMMENT #4 | | | COPIED BELOW). RESUBMITTED IN THEIR PLACES ARE | | | P.200.1A- P200.6A WHICH ARE WATER AND GAS PLANS. PLEASE | | | RESUBMIT THE PLANS WITH THE REQUESTED CORRECTIONS PER | | | COMMENT #4. | | | | | | 4) P200.1- P200.6 BUILDING A GROUND LEVEL PLANS: | | | A) SANITARY AND STORM DRAIN PIPE SIZES MISSING- TABLES | | | 710.1(1), 710.1(2), 1106.2 FBC P. | | | B) DFU'S FOR SANITARY PIPING NOT SHOWN- TABLE 710.1(1). | | | C) PROVIDE THE STORM DRAINAGE FLOW IN GPM FOR EACH | | | STORM DRAIN BRANCH AND MAIN- TABLE 1106.2 FBC P. | | | D) SHOW THE SECONDARY ROOF DRAINAGE TERMINATION | | | LOCATIONS- SEC. 1108.2 FBC P. | | | E) SHOW THE CONDENSATE AND WATER HEATER DISCHARGE | | | VERTICAL RISER LOCATIONS AND HORIZONTAL PIPING RUNS AND | | | TERMINATION LOCATIONS- SECS. 314.2.1 & 504.7.1, 504.7.2 | | | FBC P. | | | F) SHOW THE ELEVATOR SUMP PUMP LOCATIONS AND DISCHARGE | | | PIPING RUNS TO THE SANITARY DISPOSAL LOCATIONS- SEC. | | | 712.3.5 FBC P. | | | G) SHOW EMERGENCY FLOOR DRAIN LOCATIONS AND TRAP SEAL | | | PROTECTION METHOD- SEC. 1002.4 FBC P. | | | | | | 2) 2ND REQUEST FOR POTABLE WATER BACKFLOW PERMIT | | | APPLICATIONS. SHEET SP200: THE PLAN SHOWS MULTIPLE RPZ | | | BACKFLOW PREVENTERS FOR THE POTABLE WATER AND FIRE | | | SERVICE LINES FOR BUILDINGS WHICH WILL REQUIRE SEPARATE | | | PERMIT SUBMITTALS FOR EACH ONE. CONCERNING THE RPZ'S | | | FOR THE POTABLE WATER PLEASE NOTE DUE TO A CHANGE IN | | | PROCESS, THE BACKFLOW PERMITS ARE REQUIRED TO BE | | | SUBMITTED PRIOR TO APPROVAL OF THIS PLUMBING REVIEW. | | | YOU CAN SUBMIT APPLICATIONS TBD (TO BE DETERMINED) IF | | | YOU DO NOT HAVE A CONTRACTOR SELECTED BY EMAILING A | | | COMPLETED PERMIT APPLICATION TO | | | [email protected]. YOU WILL RECEIVE INSTRUCTIONS | | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATIONS ARE | | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | | AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE | | | PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL | | | CHANGE THE REVIEW STATUS TO PASS. | | | | | | A) PLEASE NOTE THAT THE SEPARATE PERMIT SUBMITTALS FOR | | | THE BACKFLOW PREVENTERS SHALL INCLUDE A MANUFACTURER'S | | | SPECIFICATION SHEET SHOWING THE MAKE, MODEL AND SIZE OF | | | THE DEVICE, AND WHICH STATES THE DEVICE IS LEAD-FREE | | | AND IS ON THE APPROVED DEVICE LIST PUBLISHED BY THE | | | UNIVERSITY OF SOUTHERN CALIFORNIA (USC). ALSO REQUIRED | | | IS A SITE OR CIVIL SHOWING THE LOCATION OF THE BACKFLOW | | | PREVENTER- SEC. 107.2.1 WPB. | | | | | | 3) P200.7 & P.200.8: 2ND REQUEST TO PROVIDE THE STORM | | | DRAINAGE FLOW IN GPM FOR EACH STORM DRAIN BRANCH AND | | | MAIN- TABLE 1106.2 FBC P. | | | | | | 4) P402A: SHOW THE LOCATION OF THE GREASE AND SOLIDS | | | INTERCEPTORS ON THE SANITARY DRAINAGE FLOOR PLANS- SEE | | | COMMENT #1 ABOVE. | | | PLEASE NOTE DUE TO A CHANGE IN PROCESS, THE GREASE | | | INTERCEPTOR PERMITS ARE REQUIRED TO BE SUBMITTED PRIOR | | | TO APPROVAL OF THIS PLUMBING REVIEW. YOU CAN SUBMIT | | | APPLICATIONS TBD (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected]. YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATIONS ARE REQUIRED AT THIS TIME. WE RECOMMEND | | | THAT YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. | | | AFTER YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA | | | EMAIL AND I WILL CHANGE THE REVIEW STATUS TO PASS. | | | GREASE INTERCEPTOR PLAN REVIEW REQUIREMENTS. | | | | | | A) EQUIPMENT SCHEDULE INDICATING THE MAKE AND MODEL AND | | | CAPACITY OF THE UNIT. | | | B) SIZING CALCULATIONS IN ACCORDANCE WITH ASME | | | A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3, | | | OR PDI G101 FOR HYDROMECHANICAL TYPES; OR SEC. 1003.3.7 | | | FOR GRAVITY TYPES. | | | C) ENLARGED PIPING DIAGRAM INCLUDING LOCATIONS AND | | | SIZES OF INLETS, OUTLETS, CLEANOUTS, FLOW CONTROL | | | VENTS, AND SAMPLING PORTS. | | | D) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | GUIDELINES WITH APPROVAL STAMP BY THE ENGINEER OF | | | RECORD- SECS.1003.3.5 OR 1003.3.7 FBC P. | | | E) ACCESS LID DETAILS INDICATING THE LIDS WILL BE HEAVY | | | DUTY TRAFFIC RATED AND WILL BE EQUIPPED WITH ACCESS | | | RESTRICTORS. HEAVY DUTY LIDS ARE ALSO REQUIRED FOR | | | CLEANOUTS, AND SAMPLING PORTS (IF INSTALLED). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-21 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-17 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2023-02-21 17:19:37 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22110628 | | | 2/21/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET SP200: THE PLAN SHOWS MULTIPLE RPZ BACKFLOW | | | PREVENTERS FOR THE POTABLE WATER AND FIRE SERVICE LINES | | | FOR BUILDINGS WHICH WILL REQUIRE SEPARATE PERMIT | | | SUBMITTALS FOR EACH ONE. CONCERNING THE RPZ'S FOR THE | | | POTABLE WATER PLEASE NOTE DUE TO A CHANGE IN PROCESS, | | | THE BACKFLOW PERMITS ARE REQUIRED TO BE SUBMITTED PRIOR | | | TO APPROVAL OF THIS PLUMBING REVIEW. YOU CAN SUBMIT AN | | | APPLICATION TBD (TO BE DETERMINED) IF YOU DO NOT HAVE A | | | CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected]. YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | | YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL | | | AND I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | | | A) PLEASE NOTE THAT THE SEPARATE PERMIT SUBMITTALS FOR | | | THE BACKFLOW PREVENTERS SHALL INCLUDE A MANUFACTURER'S | | | SPECIFICATION SHEET SHOWING THE MAKE, MODEL AND SIZE OF | | | THE DEVICE, AND WHICH STATES THE DEVICE IS LEAD-FREE | | | AND IS ON THE APPROVED DEVICE LIST PUBLISHED BY THE | | | UNIVERSITY OF SOUTHERN CALIFORNIA (USC). ALSO REQUIRED | | | IS A SITE OR CIVIL SHOWING THE LOCATION OF THE BACKFLOW | | | PREVENTER- SEC. 107.2.1 WPB. | | | | | | 2) PROVIDE SANITARY DRAINAGE AND WATER RISER DRAWINGS | | | FOR BUILDING A- SEC. 107.3.5.1.3 WPB. | | | | | | 3) PROVIDE PRIMARY AND SECONDARY ROOF DRAINAGE RISER | | | DRAWINGS- SEC. 107.3.5.1.3 WPB. | | | | | | 4) P200.1- P200.6 BUILDING A GROUND LEVEL PLANS: | | | A) SANITARY AND STORM DRAIN PIPE SIZES MISSING- TABLES | | | 710.1(1), 710.1(2), 1106.2 FBC P. | | | B) DFU'S FOR SANITARY PIPING NOT SHOWN- TABLE 710.1(1). | | | C) PROVIDE THE STORM DRAINAGE FLOW IN GPM FOR EACH | | | STORM DRAIN BRANCH AND MAIN- TABLE 1106.2 FBC P. | | | D) SHOW THE SECONDARY ROOF DRAINAGE TERMINATION | | | LOCATIONS- SEC. 1108.2 FBC P. | | | E) SHOW THE CONDENSATE AND WATER HEATER DISCHARGE | | | VERTICAL RISER LOCATIONS AND HORIZONTAL PIPING RUNS AND | | | TERMINATION LOCATIONS- SECS. 314.2.1 & 504.7.1, 504.7.2 | | | FBC P. | | | F) SHOW THE ELEVATOR SUMP PUMP LOCATIONS AND DISCHARGE | | | PIPING RUNS TO THE SANITARY DISPOSAL LOCATIONS- SEC. | | | 712.3.5 FBC P. | | | G) SHOW EMERGENCY FLOOR DRAIN LOCATIONS AND TRAP SEAL | | | PROTECTION METHOD- SEC. 1002.4 FBC P. | | | | | | 5) P200.7: | | | A) LABEL THE WASTE AND SOIL STACK LOCATIONS USING THE | | | LETTER SYMBOLS SHOWN ON P300- SEC. 107.2.1 WPB. | | | B) PROVIDE THE STORM DRAINAGE FLOW IN GPM FOR EACH | | | STORM DRAIN BRANCH AND MAIN- TABLE 1106.2 FBC P. | | | C) SHOW THE CONDENSATE AND WATER HEATER DISCHARGE | | | VERTICAL RISER LOCATIONS AND HORIZONTAL PIPING RUNS AND | | | TERMINATION LOCATIONS- SECS. 314.2.1 & 504.7.1, 504.7.2 | | | FBC P. | | | D) SHOW THE ELEVATOR SUMP PUMP LOCATIONS AND DISCHARGE | | | PIPING RUNS TO THE SANITARY DISPOSAL LOCATIONS- SEC. | | | 712.3.5 FBC P. | | | E) SHOW EMERGENCY FLOOR DRAIN LOCATIONS AND TRAP SEAL | | | PROTECTION METHOD- SEC. 1002.4 FBC P. | | | F) SHOW THE SECONDARY ROOF DRAINAGE TERMINATION | | | LOCATIONS- SEC. 1108.2 FBC P. | | | | | | 6) P200.8: | | | A) LABEL THE WASTE AND SOIL STACK LOCATIONS USING THE | | | LETTER SYMBOLS SHOWN ON P300- SEC. 107.2.1 WPB. | | | B) PROVIDE THE STORM DRAINAGE FLOW IN GPM FOR EACH | | | STORM DRAIN BRANCH AND MAIN- TABLE 1106.2 FBC P. | | | C) SHOW THE CONDENSATE AND WATER HEATER DISCHARGE | | | VERTICAL RISER LOCATIONS AND HORIZONTAL PIPING RUNS AND | | | TERMINATION LOCATIONS- SECS. 314.2.1 & 504.7.1, 504.7.2 | | | FBC P. | | | D) SHOW THE ELEVATOR SUMP PUMP LOCATIONS AND DISCHARGE | | | PIPING RUNS TO THE SANITARY DISPOSAL LOCATIONS- SEC. | | | 712.3.5 FBC P. | | | E) SHOW EMERGENCY FLOOR DRAIN LOCATIONS AND TRAP SEAL | | | PROTECTION METHOD- SEC. 1002.4 FBC P. | | | F) SHOW THE SECONDARY ROOF DRAINAGE TERMINATION | | | LOCATIONS- SEC. 1108.2 FBC P. | | | | | | 7) P300: THERE ARE TWO P300 PLAN SHEETS APPARENTLY ONE | | | FOR BUILDING B AND ONE FOR BUILDING C HOWEVER THEY ARE | | | NOT TITLED PROPERLY TO DISTINGUISH ONE FROM THE OTHER- | | | SEC. 107.2.1 WPB. | | | | | | 8) P300: THE WATER RISERS ARE INCORRECTLY LABELED AS | | | RAIN WATER LEADER RISERS- SEC. 107.2.1 WPB. | | | | | | 9) P301: THERE ARE TWO P301 PLAN SHEETS APPARENTLY ONE | | | FOR BUILDING B AND ONE FOR BUILDING C HOWEVER THEY ARE | | | NOT TITLED PROPERLY TO DISTINGUISH ONE FROM THE OTHER- | | | SEC. 107.2.1 WPB. | | | A) SAN. ISO: LABEL THE WASTE AND SOIL STACK LOCATIONS | | | USING THE LETTER SYMBOLS SHOWN ON P300- SEC. 107.2.1 | | | WPB. | | | B) STORM ISO: PROVIDE THE STORM DRAINAGE FLOW IN GPM | | | FOR EACH STORM DRAIN BRANCH AND MAIN- TABLE 1106.2 FBC | | | P. | | | | | | 10) P500 DETAIL 6: PROVIDE THE MAKE AND MODEL OF THE | | | CLEANOUT ASSEMBLY SHOWN IN THE DETAIL- SEC. 708.1.10.2 | | | FBC P. | | | | | | 11) P502 DETAILS 5 & 11: THE POOL SHALL BE UNDER | | | SEPARATE PERMIT HOWEVER CONCERNING POOL WASTE WATER | | | DISPOSAL AS SHOWN IN THE DETAILS PLEASE NOTE THE | | | FOLLOWING- | | | SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY | | | SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES | | | DEPARTMENT. | | | SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY | | | STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED | | | ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER???S | | | SPECIFICATION FOR THE DECHLORINATION SYSTEM FOR REVIEW | | | AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL | | | WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED: | | | * THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH | | | TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE | | | INLET). | | | * NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE | | | INLET TO DISCHARGE EFFLUENT. | | | * WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE | | | ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL OWNERS | | | PROPERTY BEFORE DISCHARGING ON CITY PROPERTY. | | | * DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING | | | PROPERTY. | | | * FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT | | | STEPHON HARRIS AT [email protected] OR 561-822-2168. | | | * FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE | | | CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE | | | SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561) | | | 822-2062 OR [email protected]. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-26 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-26 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2023-07-26 07:42:14 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE EROSION CONTROL DRAWINGS AND THE BACK FLOW | | | PREVENTER DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN | | | ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | 2023-07-19 15:05:38 | PLUMBING PLAN SIGNATURES PASSED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-10 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-10 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-07 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-07 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2023-03-07 14:12:47 | ALL PLANS PASSED SIGNATURE REVIEW. MP | | 2023-02-21 11:16:08 | PLUMBING (P) PLAN SHEETS APPROVED. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-25 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-25 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-11 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-11 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2023-05-11 14:16:28 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2023-06-02 |
Time |
16:44 |
Rev Time |
6.00 |
| Received By |
eschneid |
Date |
2023-06-02 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2023-06-02 16:45:03 | FAILED | | | | | | 1) THE STRUCTURAL SHEETS DO NOT MATCH SP200 SITE PLAN | | | AND A301.5 LEVEL 1.5 OVERALL FLOOR PLAN (MINOR | | | DIFFERENCES) SUBMITTED WITH THIS PERMIT NOR DO EITHER | | | OF THESE PLANS MATCH THE LATEST ARCHITECTURAL PLANS | | | (MAJOR DIFFERENCES) THAT HAVE BEEN SUBMITTED TO THE | | | CITY AS PART OF THE FORMAL SITE PLAN REVIEW. STAFF HAS | | | BEEN TOLD THAT THE STRUCTURAL SHEETS ARE THE | | | CONSTRUCTION PLANS AND THAT THE ARCHITECTURAL PLANS | | | WILL BE UPDATED TO MATCH THE STRUCTURAL SHEETS. STAFF | | | IS UNABLE TO VERIFY THAT THE LAYOUT ON THE STRUCTURAL | | | SHEETS COMPLIES WITH THE NORTHWOOD MIXED USE DISTRICT | | | DEVELOPMENT REQUIREMENTS (OR THE WAIVERS TO THE | | | REQUIREMENTS GRANTED BY THE APPROVED LEVEL III SPECIAL | | | REVIEW) SINCE THE STRUCTURAL SHEETS DO NOT MATCH THE | | | ARCHITECTURAL SETS, WHICH INCLUDE THE DATA TABLES. THE | | | FORMAL SITE PLAN SUBMITTALS MUST BE UPDATED TO MATCH | | | THE STRUCTURAL PLANS, PROVIDED THAT THE STRUCTURAL | | | PLANS MET THE NMUD REQUIREMENTS. YOU MUST PROVIDE DATA | | | TABLES THAT REFLECT CHANGES TO THE FOLLOWING AREAS OF | | | THE PLANS AND VERIFY THAT THESE CHANGES COMPLY WITH THE | | | NMUD REQUIREMENTS (OR THE APPROVED VARIANCES): | | | | | | A. TOWER FLOOR PLATES | | | B. ACTIVE USE CALCULATIONS | | | C. FENESTRATION CALCULATIONS | | | D. PLANAR BREAK CALCULATIONS | | | E. DWELLING UNIT SIZES | | | F. SETBACKS | | | | | | 2) PLEASE EXPLAIN HOW THE GROUND LEVEL OF BUILDING A | | | ADDS 10,525 SQUARE FEET TO THE PREVIOUSLY REVIEWED | | | ARCHITECTURAL PLANS. THIS NET INCREASE DOES NOT APPEAR | | | TO BE A CONVERSION OF ONE USE (EX RETAIL OR LOBBY) TO | | | ANOTHER, BUT RATHER NEW SQUARE FOOTAGE. IT IS NOT | | | OBVIOUS WHERE THIS INCREASE OCCURS SINCE THE OUTER | | | WALLS DO NOT APPEAR TO HAVE SHIFTED AND HOW THIS | | | AFFECTS THE ACTIVE USE, FENESTRATION, ETC. CALCULATIONS | | | REQUIRED BY COMMENT NUMBER 1. | | | | | | 3) PLEASE EXPLAIN WHY/HOW/WHERE THE BUILDING C TOTAL | | | SQUARE FOOTAGE INCREASE OCCURS BASED ON THE PREVIOUSLY | | | REVIEWED ARCHITECTURAL PLANS. THE DATA TABLE SHOWS 50 | | | SQUARE FEET ON THE GROUND FLOOR, BUT IT IS NOT CLEAR | | | WHERE THIS OCCURS AND HOW THIS AFFECTS THE ACTIVE USE, | | | FENESTRATION, ETC. CALCULATIONS REQUIRED BY COMMENT | | | NUMBER 1. | | | | | | 4) THE PARKING LAYOUT ON LEVELS 1.5 AND 2 HAVE CHANGED | | | FROM THE PREVIOUSLY REVIEWED ARCHITECTURAL PLANS. THE | | | PLANS UPLOADED WITH THE FOUNDATION/SHELL PERMIT DO NOT | | | INCLUDE DIMENSIONS FOR THE PARKING SPACES, DRIVE | | | AISLES, AND DISTANCE BETWEEN THE PARKING SPACES AND | | | WALLS (MINIMUM ONE FOOT REQUIRED FOR DOOR SWING). ONCE | | | THE DIMENSIONS ARE PROVIDED, STAFF CAN DETERMINE IF AND | | | ADDITIONAL PARKING SPACES NEED TO BE DESIGNATED AS | | | COMPACT SPACES. ADDITIONALLY, THE PARKING TABLES THAT | | | WERE PREVIOUSLY INCLUDED ON THE A103 PARKING SPACE | | | CALCULATION SHEETS NEED TO BE UPDATED AND INCLUDED SO | | | THAT STAFF CAN VERIFY THERE IS SUFFICIENT PARKING BASED | | | ON THE REVISED PARKING LAYOUT. | | | | | | 5) THE BICYCLE STORAGE ROOMS HAVE CHANGED FROM THE | | | PREVIOUSLY REVIEWED ARCHITECTURAL PLANS AND THERE IS NO | | | INFORMATION PROVIDED FOR STAFF TO VERIFY COMPLIANCE | | | WITH THE NMUD REQUIREMENTS. ADDITIONALLY, IT APPEARS | | | THAT THE SHOWER AND CHANGING FACILITY HAS BEEN REMOVED, | | | WHICH IS NOT PERMITTED. | | | | | | 6) SP200 AND 300 PROVIDED WITH THE FOUNDATION PERMIT DO | | | NOT ACCURATELY REFLECT THE MOST RECENT PARKING LAYOUT | | | ALONG NEW PINEWOOD, BROADWAY AVENUE OR BROADWAY | | | EXTENSION. | | | | | | 7) THE PARKING TABLE INCLUDES THE PARKING SPACES WITHIN | | | THE FDOT PORTION OF BROADWAY AS PROVIDED PARKING; | | | HOWEVER, FDOT SPECIFICALLY PROHIBITED THIS IN THEIR | | | PREDETERMINATION LETTER. THESE SPACES MUST BE REMOVED | | | FROM THE PARKING TABLE. | | | | | | 8) THE NEW PLANS SHOW STORAGE AREAS ON THE GARAGE | | | LEVELS. PLEASE EXPLAIN WHO USES THESE STORAGE AREAS. | | | PLEASE NOTE THAT ANY THAT ARE FOR A NON-RESIDENTIAL | | | USER ARE CONSIDERED AS PART OF THE COMMERCIAL SQUARE | | | FOOTAGE FOR THE PROJECT AND THUS WOULD NEED TO BE | | | FACTORED INTO THE PARKING CALCULATIONS. | | | | | | 9) SOUTH ELEVATION WIND PRESSURES DRAWING FOR BUILDING | | | A SHOWS THE WESTERNMOST BANK OF WINDOWS INCORRECTLY. | | | THEY START/END ONE FLOOR/PARAPET TO HIGH. | | | | | | 10) THE PLANS SHALL CLEARLY SHOW THE SETBACK DIMENSIONS | | | FROM THE BUILDING WALL TO THE PROPERTY LINE. | | | | | | 11) ADDITIONAL COMMENTS MAY BE ISSUED WHEN CONSISTENT, | | | ACCURATE PLANS ARE SUPPLIED. | | | | | | CONTACT ERIC SCHNEIDER @ 561-822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
ESchneid |
Date |
2023-04-04 |
Time |
14:53 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2023-04-04 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2023-04-04 14:58:55 | FAILED | | | | | | 1) THE FORMAL SITE PLAN FOR THIS PROJECT HAS NOT BEEN | | | APPROVED. ZONING WILL NOT APPROVE THIS PERMIT UNTIL THE | | | SITE PLAN IS APPROVED. | | | | | | 2) ZONING HAS IDENTIFIED THAT THE PLANS SUBMITTED WITH | | | THE PERMIT DO NOT MATCH THE LATEST SET OF PLANS | | | REVIEWED BY STAFF AS PART OF THE SITE PLAN REVIEW. THE | | | PERMIT PLANS MUST BE INTERNALLY CONSISTENT AS WELL AS | | | MATCH THE APPROVED SITE PLAN SET. | | | | | | 3) ZONING WILL NOT DO A REVIEW UNTIL PLANS THAT MATCH | | | THE APPROVED SITE PLAN ARE SUBMITTED. | | | | | | CONTACT ERIC SCHNEIDER @ 561-822-1446 | | | [email protected] |
|
|