Plan Review Details - Permit 22110588
Plan Review Stops For Permit 22110588
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-11-21 Cont ID  
Sent By cpuell Date 2022-11-21 Time 10:50 Rev Time 0.00
Received By cpuell Date 2022-11-21 Time 10:50 Sent To  
Notes
2022-11-21 10:50:53ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-01-13 Cont ID  
Sent By cthroop Date 2023-01-13 Time 16:50 Rev Time 0.00
Received By cthroop Date 2023-01-13 Time 16:08 Sent To  
Notes
2023-01-13 16:51:10PROVISO ON PLAN PAGE A1.1: SEE REVISED PLAN UNDER
 22110511 BLD-RES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-01-07 Cont ID  
Sent By cthroop Date 2023-01-07 Time 12:55 Rev Time 0.00
Received By cthroop Date 2023-01-07 Time 10:50 Sent To  
Notes
2023-01-07 12:57:483RD BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE DESIGN FLOOD ELEVATION (DFE)
 SHALL BE AT OR ABOVE 9'0" NAVD.
  
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
 (FLOOD OPENINGS ARE REQUIRED IN THE FOLLOWING ENCLOSED
 SPACES:)
 1A. ROOM 120 GARAGE (FF EL 6.5') 4 VENTS SHOWN
 1B. ROOM 114 STAIRWELL/STORAGE (FF EL 7.75') 1 VENT
 SHOWN
 1C. ROOM 110 MECHANICAL ROOM (FF EL 8.75') NO VENTS
 SHOWN
 1D. ROOM 115 HALL/LOWER LEVEL (FF EL 6.5') 1 VENT SHOWN
 1E. ROOM 118 STORAGE (FF EL 7.75') 2 VENTS SHOWN
  
 2. CORRECTED
  
 3, CORRECTED
  
 4. IDENTIFY THE TYPE AND LOCATION OF ANY FLOOD OPENINGS
 ON FLOOR PLAN A1.1 FOR ANY ENCLOSED AREA BELOW THE
 DESIGN FLOOD ELEVATION (DFE) OF 9'0" NAVD.
 R322.2.2.1INSTALLATION OF OPENINGS.
 R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION.
 (SEE LIST OF ROOMS ON LINE 1 ABOVE) (IDENTIFY MODEL OF
 SMART VENTS ON FLOOR PLAN A1.1)
  
 5. CORRECTED
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-12-17 Cont ID  
Sent By cthroop Date 2022-12-17 Time 09:41 Rev Time 0.00
Received By cthroop Date 2022-12-17 Time 08:36 Sent To  
Notes
2022-12-17 09:54:162ND BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 PLEASE REVIEW COMMENTS UNDER THE NFIP REVIEW
  
 1.
  
 2.
  
 3,
  
 4. IDENTIFY THE TYPE AND LOCATION OF ANY FLOOD OPENINGS
 ON FLOOR PLAN A1.1 FOR ANY ENCLOSED AREA BELOW THE
 DESIGN FLOOD ELEVATION (DFE) OF 9'0" NAVD.
 R322.2.2.1INSTALLATION OF OPENINGS.
 R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION.
  
 (FLOOD OPENINGS ARE REQUIRED IN THE FOLLOWING ENCLOSED
 AREAS:)
 4A) GARAGE EL. 6.0' NAVD
 4B) ENTRY EL. 6.0' NAVD
 4C) STORAGE EL. 7.75' NAVD
 4D) MECH. ROOM EL. 8.75' NAVD
  
 NEW COMMENTS:
  
 5. IDENTIFY TYPE AND MODEL OF FLOOD VENTS ON FLOOR
 PLAN.
  
 6. GARAGE IS 857SF. 5 FLOOD OPENINGS OF 200 SQ. IN.
 REQUIRED.
  
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-22 Cont ID  
Sent By cthroop Date 2022-11-22 Time 12:32 Rev Time 0.00
Received By cthroop Date 2022-11-21 Time 13:07 Sent To  
Notes
2022-11-22 12:34:581ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 PLEASE REVIEW COMMENTS UNDER THE NFIP REVIEW
  
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 2. PROVIDE A SITE PLAN....
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE
 AND INCLUDED BOUNDARY LINE SURVEY.
  
 3, GOVERNING CODES ON COVER PAGE ARE INCORRECT. THE
 CURRENT GOVERNING CODES ARE:
 2020 FLORIDA BUILDING CODE 7TH EDITION W/2017 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1 ADMINISTRATION
 2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH EDITION
 2020 FLORIDA EXISTING BUILDING CODE 7TH EDITION
 2020 FLORIDA MECHANICAL CODE 7TH EDITION
 2020 FLORIDA ACCESSIBILITY CODE 7TH EDITION
 2020 FLORIDA ENERGY CODE 7TH EDITION
 2020 FLORIDA PLUMBING CODE 7TH EDITION
 2020 FLORIDA FUEL GAS CODE 7TH EDITION
 2017 NEC
 2020 FLORIDA FIRE CODE 7TH EDITION
  
 4. IDENTIFY THE TYPE AND LOCATION OF ANY FLOOD OPENINGS
 ON FLOOR PLAN A1.1 FOR ANY ENCLOSED AREA BELOW THE
 DESIGN FLOOD ELEVATION (DFE) OF 9'0" NAVD.
 R322.2.2.1INSTALLATION OF OPENINGS.
 R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-11-21 Cont ID  
Sent By jleahy Date 2022-11-21 Time 13:37 Rev Time 0.00
Received By jleahy Date 2022-11-21 Time 13:27 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-12-19 Cont ID  
Sent By rrossano Date 2022-12-19 Time 10:15 Rev Time 0.00
Received By rrossano Date 2022-12-19 Time   Sent To  
Notes
2022-12-19 10:15:01 
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-11-28 Cont ID  
Sent By rrossano Date 2022-11-28 Time   Rev Time  
Received By rrossano Date 2022-11-28 Time   Sent To  
Notes
2022-12-03 09:58:40PLEASE PROVIDE SITE PLAN AND SHOW PROXIMITY OF CONCRETE
 WALL TO UTILITIES ALONG SOUTH PERIMETER OF PROPERTY.
 WALL IS IN VICINITY OF CITY OWNED UTILITIES. CALL 811
 TO HAVE ONE CALL UTILITIES LOCATE THE UTILITY LINE AND
 THEN MEET WITH APPROPRIATE CITY OF WPB O&M PERSONNEL
 FOR THE SPECIFIC UTILITY TO DETERMINE AMOUNT OF
 CLEARANCE NEEDED.
  
 SANITARY: CHARLES PHOENIX 561-822-2181 [email protected]
 WATER: COURTNEY MOORE 561-822-2174 [email protected]
 STORMWATER: STEPHON HARRIS 822-2185 [email protected]
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES
 DEPT., 561-494-1098, FAX: 561-494-1116 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-01-13 Cont ID  
Sent By cthroop Date 2023-01-13 Time 16:51 Rev Time 0.00
Received By cthroop Date 2022-12-28 Time 07:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-22 Cont ID  
Sent By aoliver Date 2022-12-22 Time 13:48 Rev Time 0.00
Received By aoliver Date 2022-12-14 Time 06:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-07 Cont ID  
Sent By asangele Date 2022-12-07 Time 11:09 Rev Time 0.00
Received By asangele Date 2022-12-07 Time 11:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-01-19 Cont ID  
Sent By lmarchan Date 2023-01-19 Time 09:06 Rev Time 0.00
Received By lmarchan Date 2023-01-17 Time 09:56 Sent To  
Notes
2023-01-19 07:53:45RECEIPT MU-2023-002361 - $22.46 PAID
2023-01-17 09:56:50EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-11-22 Cont ID  
Sent By cthroop Date 2022-11-22 Time 12:35 Rev Time 0.00
Received By cthroop Date 2022-11-21 Time 13:07 Sent To  
Notes
2022-11-22 12:35:57IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2023-01-13 Cont ID  
Sent By cthroop Date 2023-01-13 Time 16:51 Rev Time 0.00
Received By cthroop Date 2023-01-07 Time 10:50 Sent To  
Notes
2023-01-07 12:22:58CONSTRUCTION DRAWING EC FOR FOUNDATION ONLY. SEE EC
 UNDER 22110511 BLD-RES. CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2022-12-17 Cont ID  
Sent By cthroop Date 2022-12-17 Time 09:59 Rev Time 0.00
Received By cthroop Date 2022-12-17 Time 08:36 Sent To  
Notes
2022-12-17 10:11:052ND NFIP REVIEW
 CORRECTIONS REQUIRED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC)
 SUBMITTED FOR REVIEW:
 ADDRESS THE FOLLOWING COMMENTS:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1.
  
 2. LINES A9 A THRU A9 D. DATA MISSING.
 (LINE A9A COVER PAGE STATES GARAGE IS 857SF)
 (LINES A9B & A9C DATA MISSING)
 (LINE A9D EOR STATES FLOOD OPENINGS WILL BE ENGINEERED
 OPENINS)
  
  
 3.
  
 4. LINE C2A) LOWEST FLOOR.
 PER R322.1.5LOWEST FLOOR.
 (LOWEST FLOOR IS 6.5 ENTRY AREA OFF OF GARAGE)
  
 5. LINE C2B) MISSING DATA.
 (NEXT HIGHEST FLOOR IS 7.75' STORAGE)
  
 6. C2D) MISSING DATA.
 (GARAGE FF EL. IS 6.5;)
  
 7.
  
 8. SECTION D COMMENTS: MISSING COMMENTS: USE THIS SPACE
 TO DESCRIBE TYPE OF EQUIPMENT IN C2E) AND IT'S
 LOCATION, ENGINEERED FLOOD OPENINGS, IF PRESENT AND
 OTHER RELEVANT INFORMATION NOT SPECIFIED ESLSEWHWERE ON
 THE CERTIFICATE.
 (STATE MODEL NUMBER OF SNART VENTS. INCLUDE SF
 COVERGAGE OF EACH VENT)
  
 NEW COMMENT:
  
 9. EC MISSING PAGES 5 & 6. FEMA REQUIRES A COMPLETE
 CERTIFICATE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2022-11-22 Cont ID  
Sent By cthroop Date 2022-11-22 Time 10:50 Rev Time 0.00
Received By cthroop Date 2022-11-21 Time 14:22 Sent To  
Notes
2022-11-22 10:51:481ST NFIP PLAN REVIEW
 CORRECTIONS REQUIRED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATION
 (BFE) OF 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC)
 SUBMITTED FOR REVIEW:
 ADDRESS THE FOLLOWING COMMENTS:
  
 1. LINE A7. BUILDING DIAGRAM SHOULD BE 1B PER EC
 INSTRUCTIONS.
  
 2. LINES A9 A THRU A9 D. DATA MISSING.
  
 3. LINE B9 THE BUILDING IS LOCATED IN MORE THAN ONE
 FLOOD ZONE, LIST ALL BFE'S: BASE FLOOD ELEVATIONS ARE 6
 AND 7.
  
 4. LINE C2A) LOWEST FLOOR.
 PER R322.1.5LOWEST FLOOR.
  
 5. LINE C2B) MISSING DATA.
  
 6. C2D) MISSING DATA.
  
 7. LINE C2E) MISSING DATA.
  
 8. SECTION D COMMENTS: MISSING COMMENTS: USE THIS SPACE
 TO DESCRIBE TYPE OF EQUIPMENT IN C2E) AND IT'S
 LOCATION, ENGINEERED FLOOD OPENINGS, IF PRESENT AND
 OTHER RELEVANT INFORMATION NOT SPECIFIED ESLSEWHWERE ON
 THE CERTIFICATE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-12-29 Cont ID  
Sent By rwbrown Date 2022-12-29 Time 13:44 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-12-16 Cont ID  
Sent By ccole Date 2022-12-16 Time 07:08 Rev Time 0.00
Received By ccole Date 2022-12-15 Time 17:03 Sent To  
Notes
2022-12-16 07:09:242ND REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22110588
 12/16/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P-2 & P-8: SHEET P-2 SHOWING THE 3-INCH
 UNDERGROUND BUILDING DRAIN AND BRANCHES WAS NOT REVISED
 TO MATCH THE NEW SANITARY RISER (P-8) WHICH SHOWS
 4-INCH DRAINS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-11-21 Cont ID  
Sent By ccole Date 2022-11-21 Time 14:55 Rev Time 0.00
Received By ccole Date 2022-11-21 Time 14:29 Sent To  
Notes
2022-11-21 14:59:111ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22110588
 11/21/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. THE COMMENTS LISTED BELOW
 FROM THE MAIN HOUSE
  
 1) SHEET P2: PROVIDE A SANITARY DRAINAGE AND VENT
 ISOMETRIC DRAWING- SEC. 107.3.5.3 WPB.
  
 2) P2: THE MAIN HOUSE PLANS SHOW 6 FULL BATHS, 2 HALF
 BATHS, 2 LAUNDRY ROOMS AND TWO OTHER SINKS, PLEASE
 REFER TO TABLE P3004.1 FBC RES AND PROVIDE DFU
 CALCULATIONS. IT APPEARS THE 3-INCH BUILDING DRAIN MAY
 HAVDE TO BE INCREASED IN DIAMETER TO 4-INCH- TABLE
 P3005.4.2.
  
 3) P2: SHOW THE LOCATION OF THE REQUIRED CLEANOUT AT
 THE JUNCTION OF THE BUILDING DRAIN AND SEWER- SEC.
 P3005.2.3
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-03-03 Cont ID  
Sent By dbattles Date 2023-03-03 Time 11:07 Rev Time 0.00
Received By dbattles Date 2023-03-03 Time 11:07 Sent To  
Notes
2023-03-03 11:08:23PRIVATE PROVIDER INSPECTION
 DOCUMENTS SENT TO FILENET.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-01-07 Cont ID  
Sent By cthroop Date 2023-01-07 Time 11:17 Rev Time 0.00
Received By cthroop Date 2023-01-07 Time 10:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-12-17 Cont ID  
Sent By cthroop Date 2022-12-17 Time 09:41 Rev Time 0.00
Received By cthroop Date 2022-12-17 Time 08:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-21 Cont ID  
Sent By cthroop Date 2022-11-21 Time 14:54 Rev Time 0.00
Received By cthroop Date 2022-11-21 Time 13:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-12-21 Cont ID  
Sent By asangele Date 2022-12-21 Time 10:43 Rev Time 0.00
Received By asangele Date 2022-12-21 Time 10:43 Sent To  
Notes
2022-12-21 11:18:2412/21/2022
  
 PERMIT CAN ONLY BE FOR FOUNDATION.
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-12-07 Cont ID  
Sent By asangele Date 2022-12-07 Time 11:09 Rev Time 0.00
Received By asangele Date 2022-12-07 Time 11:09 Sent To  
Notes
***NONE***