Plan Review Details - Permit 22110359
Plan Review Stops For Permit 22110359
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-02-13 Cont ID  
Sent By rrossano Date 2023-02-13 Time   Rev Time 0.00
Received By rrossano Date 2023-02-13 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-01-30 Cont ID  
Sent By rrossano Date 2023-01-30 Time   Rev Time 0.00
Received By rrossano Date 2023-01-30 Time   Sent To  
Notes
2023-01-30 12:37:48PLEASE ADDRESS FIRE COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-02-07 Cont ID  
Sent By pleduc Date 2023-02-07 Time   Rev Time 0.00
Received By pleduc Date 2023-02-07 Time 11:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-01-17 Cont ID  
Sent By pleduc Date 2023-01-17 Time   Rev Time 0.00
Received By pleduc Date 2023-01-17 Time 10:16 Sent To  
Notes
2023-01-17 10:16:18THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS A SITE PLAN PROVIDED. HOWEVER, THIS IS NO
 SPECIFIC LOCATION INDICATED FOR THE PROPOSED FIRE LINE.
  
 FOR THE OFFICIAL RECORD AND CLARIFICATIONS, PLEASE
 PROVIDE A HIGHLIGHTED LOCATION FOR THE PROPOSED FIRE
 LINE.
  
  
 1A) THERE ARE NO INDICATIONS OF COMPLIANCE WITH NFPA
 24.
  
 THE PROPOSED SHALL BE INSTALLED, INSPECTED AND TESTED
 PER NFPA AND MANUFACTURES SPECIFICATIONS.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A NOTE
 OF ACKNOWLEDGMENT ON THE PLAN SHEETS.
  
  
 1B) THERE ARE NO MANUFACTURES SPECIFICATION SHEETS FOR
 THE PROPOSED FIRE LINE THAT INDICATES COMPLIANCE WITH
 NFPA.
  
 PLEASE PROVIDE SPECIFIC DETAILS.
  
  
 1C) ENSURE THE APPLICABLE JOINT RESTRAINTS ARE
 INSTALLED AND TORQUED PER MANUFACTURES SPECS AND JOINTS
 SHALL NOT BE COVERED OVER PRIOR TO FIRE INSPECTION.
  
 A TORQUE WRENCH SHALL BE ON SITE WITH THE INSTALLING
 CONTRACTOR FOR CONFIRMATION AND VERIFICATION AT THE
 TIME OF FIRE INSPECTION.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A NOTE
 OF ACKNOWLEDGMENT ON THE PLAN SHEETS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-14 Cont ID  
Sent By cthroop Date 2023-02-14 Time 11:05 Rev Time 0.00
Received By cthroop Date 2023-02-06 Time 11:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-31 Cont ID  
Sent By mpeterso Date 2023-01-31 Time 13:02 Rev Time 0.00
Received By mpeterso Date 2023-01-10 Time 09:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-02-14 Cont ID  
Sent By cthroop Date 2023-02-14 Time 11:04 Rev Time 0.00
Received By cthroop Date 2023-02-14 Time 11:02 Sent To  
Notes
2023-02-14 11:05:182ND SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-31 Cont ID  
Sent By mpeterso Date 2023-01-31 Time 12:54 Rev Time 0.00
Received By mpeterso Date 2023-01-31 Time 12:54 Sent To  
Notes
2023-01-31 13:01:58SIGNATURE REVIEW FAILED
  
 1) PLANS IN BOTH DRAWING AND SIGNATURE FOLDERS DO NOT
 INDICATE A CETIFIABLE DIGITAL SIGNATURE OF THE EOR/AOR
 AS REQUIRED. PLEASE CORRECT AS OUTLINED BELOW.
  
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  