Plan Review Details - Permit 22110328
Plan Review Stops For Permit 22110328
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-02-24 Cont ID  
Sent By rmcdouga Date 2023-02-24 Time 09:37 Rev Time 0.00
Received By rmcdouga Date 2023-02-24 Time 09:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-02-02 Cont ID  
Sent By rmcdouga Date 2023-02-02 Time 07:49 Rev Time 0.00
Received By rmcdouga Date 2023-02-02 Time 07:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-10 Cont ID  
Sent By rmcdouga Date 2023-01-10 Time 10:19 Rev Time 0.00
Received By rmcdouga Date 2023-01-10 Time 10:14 Sent To  
Notes
2023-01-10 10:19:45PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10
 FEET FROM ANY OPENINGS INTO A BUILDING. FBC-R303.5.1
 INTAKE OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR
 INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET
 (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT,
 SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, STREETS,
 ALLEYS, PARKING LOTS AND LOADING DOCKS.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-12-12 Cont ID  
Sent By rperdomo Date 2022-12-12 Time 15:02 Rev Time 0.00
Received By rperdomo Date 2022-12-12 Time 11:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-02-24 Cont ID  
Sent By rmcdouga Date 2023-02-24 Time 09:38 Rev Time 0.00
Received By rmcdouga Date 2023-02-07 Time 12:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-02 Cont ID  
Sent By rmcdouga Date 2023-02-02 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2023-01-10 Time 16:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-10 Cont ID  
Sent By rmcdouga Date 2023-01-10 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2022-11-29 Time 07:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-02-24 Cont ID  
Sent By rmcdouga Date 2023-02-24 Time 09:38 Rev Time 0.00
Received By rmcdouga Date 2023-02-24 Time 09:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-02-02 Cont ID  
Sent By rmcdouga Date 2023-02-02 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2023-02-02 Time 07:51 Sent To  
Notes
2023-02-02 07:49:48THE ENGINEER'S DIGITAL SIGNATURE ON THE GENERATOR PAD
 DRAWING COULD NOT BE VERIFIED. ELECTRONICALLY SUBMITTED
 DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT OR
 ENGINEER'S DIGITAL SIGNATURE ON THEM. FS 481 & FAC 61G1
 OR FS 471 & FAC 61G15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-10 Cont ID  
Sent By rmcdouga Date 2023-01-10 Time 10:19 Rev Time 0.00
Received By rmcdouga Date 2023-01-10 Time 10:14 Sent To  
Notes
2023-01-10 10:23:38THE ENGINEER'S DIGITAL SIGNATURE ON THE GENERATOR PAD
 DRAWING COULD NOT BE VERIFIED. ELECTRONICALLY SUBMITTED
 DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT OR
 ENGINEER'S DIGITAL SIGNATURE ON THEM. FS 481 & FAC 61G1
 OR FS 471 & FAC 61G15

Review Stop Z ZONING
Rev No 2 Status P Date 2023-01-13 Cont ID  
Sent By asangele Date 2023-01-13 Time 14:36 Rev Time 0.00
Received By asangele Date 2023-01-13 Time 14:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-12-07 Cont ID  
Sent By asangele Date 2022-12-07 Time 14:01 Rev Time 0.00
Received By asangele Date 2022-12-07 Time 14:01 Sent To  
Notes
***NONE***