Plan Review Details - Permit 22110317
| Plan Review Stops For Permit 22110317 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-02-13 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-02-13 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-01-03 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-03 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2023-01-03 18:17:47 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 4501.17 THE WEST PORTION OF THE FENCE APPEARS | | | TO HAVE A GATE THAT SWINGS TOWARDS THE POOL. REVISE SO | | | GATE SWING IS CLEAR AND COMPLIES WITH POOL BARRIER | | | REQUIREMENTS. | | | | | | 2. FBC R 4501.17 CLARIFY OPENING SIZE FOR THE CHAIN | | | LINK FENCE. | | | | | | 3. FBC R 4501.17 THE SURVEY DOES NOT SHOW A WALL ON THE | | | SUBJECT PROPERTY, REVISE PLAN TO SHOW A COMPLETE POOL | | | BARRIER. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-02-13 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-27 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-01-03 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-11-28 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-07 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-07 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-12-16 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-12-16 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |