Plan Review Details - Permit 22110237
| Plan Review Stops For Permit 22110237 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-02-13 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-02-13 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-02-03 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
2023-02-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-02 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-04 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-04 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2023-04-04 06:39:04 | THERE IS NOTHING I CAN REVIEW. THERE IS A CLOUDED NOTE | | | ADDED TO SHEET M1-01 THAT STATES; GENERATOR WILL BE | | | UNDER A SEPARATE MECHANICAL PERMIT APPLICATION AND PLAN | | | REVIEW. THIS GENERATOR IS INSIDE A RATED ROOM ON THE | | | FIRST FLOOR. THERE IS NO MENTION AS TO THE TYPE OF | | | GENERATORGOING INTO THIS GENERATOR ROOM ON THE ORIGINAL | | | DRAWINGS, THERE IS NO FUEL LINE DRAWINGS, NO | | | VENTILATION DRAWINGS, NO MUFFLER SPECS. NO DESIGN | | | SHOWING WHERE THE EXHAUST AND INTAKE ARE TO BE LOCATED | | | FOR THIS GENERATOR AND ROOM. I HAVE NOTHING TO REVIEW. | | | PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS GENERATOR | | | AND GENERATOR ROOM. FBC 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-11-15 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-11-15 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2022-11-15 13:13:07 | PP INSPECTIONS -AC- ABSOLUTE CIVIL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
AVolcy |
Date |
2023-02-16 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-02-16 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |