| Plan Review Stops For Permit 22110052 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-12-13 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-12-13 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2022-12-13 17:00:34 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
N |
Date |
2023-01-11 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
2023-01-11 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
2023-01-11 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-06 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-07 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2023-02-07 16:01:13 | NEW MANUFACTURED BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PREFAB MANUFACTURED BUILDINGS NEED TO BE FLORIDA | | | STATE APPROVED - PLEASE PROVIDE THE FLORIDA STATE | | | MANUFACTURED BUILDING APPROVAL FRONT PAGE - SEE ( | | | FLORIDABUILDING.ORG ) - FBC WPB 107.3 EXCEPTION (1) | | | | | | 2) THE FOUNDATION DRAWING (F1) IS NOT PART OF THE PRE | | | FAB MANUFACTURED BUILDING STATE APPROVAL AND WILL NEED | | | TO BE SIGNED AND SEALED BY THE DESIGNER - SIGNED AND | | | SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | 3) FOUNDATION DRAWINGS NEED TO SHOW THE WIND DESIGN | | | PARAMETERS ( WIND SPEED, RISK CATEGORY, EXPOSURE ) USED | | | FOR THE WIND DESIGN PER FBC 1603.1.4 | | | | | | 4) A SEPARATE PERMIT IS REQUIRED FOR - DUMPSTER | | | ENCLOSURE, PARKING LOT | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2023-01-10 12:50:54 | NEW MANUFACTURED BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE FLORIDA STATE MANUFACTURED | | | BUILDING APPROVAL FRONT PAGE. | | | | | | 2) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING | | | INFORMATION FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION | | | DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT | | | SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE | | | THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | | WATER RETAINING SWALES) | | | | | | 3) THE FOUNDATION DRAWING (F1) IS NOT PART OF THE | | | PRODUCT APPROVAL AND WILL NEED TO BE SIGNED AND SEALED | | | BY THE DESIGNER - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). | | | | | | 4) PLEASE PROVIDE A SURVEY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-06 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-06 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-07 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-07 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2023-02-07 14:03:42 | PASSED ELECTRIC REVIEW FOR ELECTRIC SERVICE ONLY. | | | SUBMITTAL IS FOR MANUFACTURED BUILDING WITH DPBR | | | APPROVED PLANS. PLANS CAN BE FOUND AT WEBSITE BELOW | | | | | | HTTPS://WWW.FLORIDABUILDING.ORG/MB/MB_PLAN_SRCH.ASPX | | | | | | PFS CORPORATION (WI) AGENCY PLAN # G22SB2-REV 1 | | | | | | PLAN TRACKING # 39846-R1 | | | | | | DATE ACCEPTED 11/15/2022 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-04 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-03 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2023-01-04 10:36:01 | PASSED ELECTRIC REVIEW FOR ELECTRIC SERVICE ONLY. | | | SUBMITTAL IS FOR MANUFACTURED BUILDING WITH DPBR | | | APPROVED PLANS. PLANS CAN BE FOUND AT WEBSITE BELOW | | | | | | HTTPS://WWW.FLORIDABUILDING.ORG/MB/MB_PLAN_SRCH.ASPX | | | | | | PFS CORPORATION (WI) AGENCY PLAN # G22SB2-REV 1 | | | | | | PLAN TRACKING # 39846-R1 | | | | | | DATE ACCEPTED 11/15/2022 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2023-02-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-12-27 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2022-12-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-27 08:29:05 | PASSED WITH PROVISOS: | | | | | | 1. ADDRESS ANY OTHER DISCIPLINES' COMMENTS. | | | 2. UPLOAD APPROVED ENGINEERING PLANS (TO BE RELEASED AT | | | PENDING ENGINEERING PRE-CONSTRUCTION MEETING). | | | | | | THANKS, | | | RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES | | | DEPT., 561-494-1098, FAX: 561-494-1116 [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-28 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-07 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-12-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-12-21 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2022-12-21 10:45:07 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS ON THE ELECTICAL PLAN SHEET E | | | 1 OF EXIT SIGNS LEADING OUT OF THE RESTROOM AND OUT OF | | | THE OPENING TO THE REAR EXIT. | | | | | | HOWEVER, THE RESTROOM DOOR OPENS OUT INTO THE EXIT | | | TRAVEL PATH AND RESTRICTS EGRESS DUE TO THE EQUIPMENT | | | INSTALLATIONS. | | | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL | | | LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF | | | AN AISLE, A CORRIDOR, | | | A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF | | | THE FOLLOWING | | | CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING | | | BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENT OF | | | 7.2.1.4.3.2. | | | | | | 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL | | | NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED | | | WIDTH OF AN AISLE, | | | A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR | | | LEAF IS EQUIPPED | | | WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT | | | REQUIRED BY THE PROVISIONS | | | OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS | | | TRAVEL. | | | | | | 7.3.4 MINIMUM WIDTH. | | | | | | 7.3.4.1 THE WIDTH OF ANY MEANS OF EGRESS, UNLESS | | | OTHERWISE PROVIDED | | | IN 7.3.4.1.1 THROUGH 7.3.4.1.3, SHALL BE AS FOLLOWS: | | | (1) NOT LESS THAN THAT REQUIRED FOR A GIVEN EGRESS | | | COMPONENT IN THIS | | | CHAPTER OR CHAPTERS 11 THROUGH 43 | | | (2) NOT LESS THAN 36 IN. (915 MM) WHERE ANOTHER PART OF | | | THIS CHAPTER | | | AND CHAPTERS 11 THROUGH 43 DO NOT SPECIFY A MINIMUM | | | WIDTH | | | | | | 7.3.4.1.1* THE WIDTH OF EXIT ACCESS SERVING NOT MORE | | | THAN SIX PEOPLE | | | AND HAVING A LENGTH NOT EXCEEDING 50 FT (15 M) SHALL | | | MEET BOTH OF THE | | | FOLLOWING CRITERIA: | | | (1) THE WIDTH SHALL BE NOT LESS THAN 18 IN. (455 MM), | | | AT AND BELOW A | | | HEIGHT OF 38 IN. (965 MM), AND NOT LESS THAN 28 IN. | | | (710 MM) ABOVE | | | A HEIGHT OF 38 IN. (965 MM). | | | (2) A WIDTH OF NOT LESS THAN 36 IN. (915 MM) FOR NEW | | | EXIT ACCESS, AND | | | NOT LESS THAN 28 IN. (710 MM) FOR EXISTING EXIT ACCESS, | | | SHALL BE | | | CAPABLE OF BEING PROVIDED WITHOUT MOVING PERMANENT | | | WALLS | | | | | | 7.3.4.2 WHERE A SINGLE EXIT ACCESS LEADS TO AN EXIT, | | | ITS CAPACITY IN TERMS | | | OF WIDTH SHALL BE NOT LESS THAN THE REQUIRED CAPACITY | | | OF THE EXIT TO WHICH | | | IT LEADS | | | | | | PLEASE REVIEW AND PROVIDE THE DIMENSION FOR PROPER | | | CLEARANCE OR REMOVE THE EXIT SIGN OVER THE OPENING TO | | | THE REAR AND PALCE ONE OVER ANY OF THE OTHER EXTERIOR | | | DOORS IN THE FRONT. | | | | | | | | | 2) THE DOOR SCHEDULE INDICATES LOCKING HARDWARE ON D3 | | | DOORS. | | | | | | IF ONE OF THOSE DOORS HAS THE EXIT SIGN MOVED OVER IT, | | | THE LOCKING HARDWARE SHALL COMPLY WITH NFPA 101 CH 7, | | | MEANS OF EGRESS. | | | | | | 38.2.2.2.3* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE | | | PERMITTED ONLY ON | | | PRINCIPAL ENTRANCE/EXIT DOORS. | | | | | | PLEASE REVIEW AND PROVIDE THE APPLICABLE DETAILS OR A | | | NOTE OF ACKNOWLEDGMENT. | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-03-09 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-03-09 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-06 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-27 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-02-15 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-02-15 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-11 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-01-11 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-12-19 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-03 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-24 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2023-03-01 16:48:09 | RECEIPT MU-2023-008688 - $24,612.39 PAID | | 2023-02-24 09:32:49 | EMAILED IMPACT FOR REVIEW PER R MCPHERSON-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2023-01-10 12:54:02 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-01 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-01 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2023-02-07 08:48:57 | 2ND REVIEW FMC | | | PERMIT: 22110052 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | PROVIDE THE PREVIOUSLY REQUESTED MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS FROM 1ST CYCLE REVIEW BELOW: | | | | | | 4) PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FEC C403.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-29 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-29 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2022-12-29 15:11:30 | 1ST REVIEW FMC | | | PERMIT: 22110052 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHOW ON THE ROOF DRAWING, M2, THAT THE RTU-1, CU-1 | | | AND CU-2 AND COOLER CONDENSER WILL MEET THE GUARD | | | PROTECTION REQUIREMENTS OF FMC 306.5 | | | | | | 2) SHOW ON THE ROOF DRAWING, M2, THAT THE RTU-1, CU-1, | | | CU-2 AND COOLER CONDENSER WILL MEET THE GUARD | | | PROTECTION OF FMC 304.11 | | | | | | 3) ADD A NOTE ON THE DRAWING THAT THE REFRIGERATION | | | WILL REQUIRE A SEPARATE PERMIT AND MECHANICAL REVIEW AS | | | IT WILL NOT BE REVIEWED UNDER THIS PERMIT. | | | | | | 4) PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FEC C403.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-28 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-28 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-21 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-21 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2023-02-21 07:26:49 | 3RD PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | 2. DONE | | | | | | 3. NOT ADDRESSED ---- 2020 1003.3.5.1 - PLEASE DETAIL | | | YOUR GREASE WASTE CALCULATIONS AND NECESSITY. | | | | | | 4. DONE | | | | | | 5. DONE | | | | | | 6. DONE | | | | | | ITEMS ADDRESSED BY OTHERS DOES NOT REMOVE IT FROM THE | | | REQUIREMENTS OF THIS REVIEW. PLEASE ADDRESS THESE | | | ITEMS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-07 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-07 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2023-02-07 16:09:15 | 3RD PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | 2. DONE | | | | | | 3. NOT ADDRESSED ---- 2020 1003.3.5.1 - PLEASE DETAIL | | | YOUR GREASE WASTE CALCULATIONS AND NECESSITY. | | | | | | 4. NOT ADDRESSED ------2017 WPB AMEND ??? 107.3 -- THE | | | BACKFLOW DEVICE AT THE UTILITY CONNECTION AND THE | | | GREASE TRAP REQUIRE SEPARATE PERMITS THAT ARE REQUIRED | | | TO BE APPLIED FOR PRIOR TO ISSUANCE OF THE PRIMARY | | | PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN APPLICATION | | | ???TBD??? (TO BE DETERMINED) IF YOU DO NOT HAVE A | | | CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected] . YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | | YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL | | | AND I WILL COMPLY THAT PARTICULAR COMMENT. | | | | | | 5. NOT ADDRESSED ------ 2017 WPB AMENDS 107.3.5.1.3 - | | | PLEASE SUBMIT A SITE PLAN FOR THE LOCATION OF THE | | | BACKFLOW AND GREASE TRAP. | | | | | | 6. NOT ADDRESSED ------- 2017 WPB AMENDS | | | 107.3.5.1.3/2020 FPC 403.1.4 - SUBMIT A SITE PLAN THAT | | | SHOWS THE OUTDOOR ASSEMBLLY AREA TO SHOW A LACK OF | | | OUTDOOR SEATING OR ASSEMBLY AREA. IF THERE IS OUTDOOR | | | SEATING OR ASSEMBLY AREA, PUBLIC RESTROOMS MAY BE | | | REQUIRED BY 403.1.4 | | | | | | ITEMS ADDRESSED BY OTHERS DOES NOT REMOVE IT FROM THE | | | REQUIREMENTS OF THIS REVIEW. PLEASE ADDRESS THESE | | | ITEMS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-30 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-12-30 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2022-12-30 13:39:20 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 403.3.2 - TOILET ROOMS SHALL NOT OPEN | | | DIRECTLY INTO A ROOM USED FOR THE PREPARATION OF FOOD | | | FOR SERVICE TO THE PUBLIC. | | | | | | 2. 2020 FPC 607.1.1 - PLEASE SHOW A WATER HEATER DETAIL | | | AND INCLUDE THE REQUIRED MIXING VALVE IN COMPLIANCE | | | WITH ASSE 1017. | | | | | | 3. 2020 1003.3.5.1 - PLEASE DETAIL YOUR GREASE WASTE | | | CALCULATIONS AND NECESSITY. | | | | | | 4. 2017 WPB AMEND ??? 107.3 -- THE BACKFLOW DEVICE AT | | | THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION ???TBD??? | | | (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR | | | SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO | | | [email protected] . YOU WILL RECEIVE INSTRUCTIONS | | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS | | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | | AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE | | | PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL | | | COMPLY THAT PARTICULAR COMMENT. | | | | | | 5. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE SUBMIT A SITE | | | PLAN FOR THE LOCATION OF THE BACKFLOW AND GREASE TRAP. | | | | | | 6. 2017 WPB AMENDS 107.3.5.1.3/2020 FPC 403.1.4 - | | | SUBMIT A SITE PLAN THAT SHOWS THE OUTDOOR ASSEMBLLY | | | AREA TO SHOW A LACK OF OUTDOOR SEATING OR ASSEMBLY | | | AREA. IF THERE IS OUTDOOR SEATING OR ASSEMBLY AREA, | | | PUBLIC RESTROOMS MAY BE REQUIRED BY 403.1.4 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2023-01-10 12:52:56 | PRE MANUFACTURED BUILDING |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-06 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-06 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2023-03-06 11:23:46 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE CIVIL DRAWINGS - C-05, C-06, C-07, C-08, C-09, | | | C-12 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-07 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-07 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2023-02-07 16:10:19 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING F1 DOES NOT SHOW AS DIGITALLY SIGNED IN | | | ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | 2023-02-07 08:50:00 | MECHANICAL SHEETS REQUIRE THE DIGITAL SIGNATURE OF THE | | | DESIGNER. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2023-01-10 12:52:19 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING F1 DOES NOT SHOW AS DIGITALLY SIGNED IN | | | ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-03-09 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-03-09 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-03-06 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-03-06 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-02-15 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-02-15 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-04 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-04 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2023-01-04 17:19:52 | FAILED | | | 1/4/2022 | | | | | | PLEASE PROVIDE A PROPERTY SURVEY WITH LABELED SETBACKS | | | OF THE BUILDING. ADDITIONALLY THE PROPOSED USE BEING A | | | COFFEE DRIVE THROUGH WILL MEET THE REQUIRED PARKING | | | REQUIREMENTS. PLEASE CLEARLY IDENTIFY THE EMPLOYEE | | | PARKING SPACES. | | | | | | ARTICLE XV. SECTION 94-486 | | | 37. DRIVE THROUGH FACILITIES, EXCEPT RESTAURANTS AS | | | PRINCIPAL USES | | | 1 PER EMPLOYEE FOR SHIFT WITH MOST EMPLOYEES, STACKING | | | LANE TO ACCOMMODATE 5 CARS | | | | | | | | | NEEDS TO PROVIDE THE GROSS BUILDING AREA AND SITE AREA. | | | | | | ARTICLE SECTION 94-145 | | | MAX. FAR WITH COMMMERICAL (C) FUTURE 0.75 | | | | | | | | | A SEPARATE PERMIT IS REQUIRED FOR: | | | | | | LANDSCAPE | | | SIGNAGE | | | AWNING | | | MECHANICAL EQUIPMENT | | | | | | | | | | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] | | | |
|
|