Plan Review Details - Permit 22101430
Plan Review Stops For Permit 22101430
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-03-17 Cont ID  
Sent By dbattles Date 2023-03-17 Time 10:22 Rev Time 0.00
Received By dbattles Date 2023-03-17 Time 10:22 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-02-13 Cont ID  
Sent By jwitmer Date 2023-02-13 Time 10:53 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2023-02-13 10:53:03COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING
 THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS
 PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM
 BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION
 WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-03-22 Cont ID  
Sent By dbattles Date 2023-03-22 Time 15:14 Rev Time 0.00
Received By dbattles Date 2023-03-22 Time 14:59 Sent To  
Notes
2023-03-22 15:14:42PROVISO:
 PLEASE PROVIDE A SUBMITTAL FOR FENESTRATION THAT
 INCLUDES THE DESIGNER OF RECORDS APPROVAL STAMP.
 ALSO, MAKE SELECTIONS IN THE PRODUCT APPROVAL THAT MEET
 THE DESIGN CRITERIA.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-03-21 Cont ID  
Sent By jwitmer Date 2023-03-21 Time 13:58 Rev Time 0.00
Received By jwitmer Date 2023-03-21 Time 12:52 Sent To  
Notes
2023-03-21 13:58:12WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22101430
 ADD: 550, 580 EXECUTIVE CENTER DR.
  
 W. P. B. PERMIT: 22101430
 ADD: 540 EXECUTIVE CENTER DR.
  
 CONT: LEGACY CONSTRUCTION SERVICES, INC.
 TEL: 216-297-2170
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. MARCH 21ST/2023
 ACTION: DENIED
  
 1) COMPLIED. PERMIT 22101425. SHEET G103 BUILDING CODE
 DATA, LEASING / COMMUNITY OFFICE FLOOR PLAN.
  
  
 2) COMPLIED.
  
 3) COMPLIED. SHEET A900. 2020 FBC-B 1603.1.4 WIND
 DESIGN CRITERIA.
  
 4A) NOTE EITHER ALL PRODUCT APPROVALS ARE REVIEWED OR
 NONE AND SUBMITTED LATER AS NO FEE DEFERRED SUBMITTALS.
 SEMI-COMPLIED. SHEET 540 & 580 FLOOR PLANS. NOTE # 1
 REMOVE AND REPLACE VINYL WINDOWS AND EXTERIOR DOORS.
 NOTE # 5 TO REMOVE & REPLACE ALL EXTERIOR DOORS.
 COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS AND
 CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 PGT PATIO DOORS DID NOT LOAD, WILL NOT OPEN FOR REVIEW
 NO EXTERIOR SWING DOORS WERE SUBMITTED.
 (B) WINDOWS & MULLIONS
 PGT HORIZONTAL ROLLERS NOA-20-0406.01 THE NOA IS NOT
 HIGHLIGHTED AS REQUESTED COMMENT 4F.
 PGT SINGLE HUNG WINDOW NOA 20-0401.03 IS NOT
 HIGHLIGHTED AS REQUESTED COMMENT 4F.
 SHEET A-900 DETAILS 8 & 9 SHOW WINDOWS BUT THEY DO NOT
 STATE IF THEY ARE HORIZONTAL SLIDERS OR 2 SINGLE HUNG
 WINDOWS REQUIRING MULLIONS.
 (C) STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, EFIS
 SYSTEMS,
  
 4B) 2ND REQUEST. W. P. B. 107.3.4. PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY FLORIDA
 ADMINISTRATIVE CODE RULE 61G20 SHALL BE REVIEWED AND
 APPROVED IN WRITING (SHOP DRAWING STAMP OF APPROVAL) BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 4C) NOTICE ONLY: DELEGATED ENGINEERING. 61G15-30.003
 ENGINEERING DOCUMENT CLASSIFICATION. FL 61G-15-30.006
 (3) THE DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 4D) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 4E) 2ND REQUEST, PGT PATIO DOOR PRODUCT APPROVAL DID
 NOT OPEN WILL NEED REVIEW FOR PRESSURES AND SILL
 HEIGHT, FOR POSITIVE PRESSURES.
 1ST ROUND OF COMMENTS. 2020 FBC-B 1709.5.1 HABITAT
 SPACES, WATER INTRUSION. EXTERIOR DOORS AND WINDOWS.
 EXCEPTION # 2. SILL LIMITING FACTOR.
  
 4F) 2ND REQUEST. IDENTIFY GLAZING/ MULLIONS. PLEASE
 IDENTIFY IN THE PRODUCT APPROVAL BEFORE SUBMITTING TO
 DESIGNER OF RECORD AND BEFORE SUBMISSION TO THE
 BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, SILL
 HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
 UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER???S INSTRUCTIONS. FASTENER SIZE AND
 SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND
 SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING
 USED IN THE TESTS.
  
 5) COMPLIED NOT APPLICABLE.
  
 6A) SEMI-COMPLIED. A-900 DOOR SCHEDULE NOW SHOWS METAL
 LOUVER DOOR BUT STILL HAS WOOD FRAME, EITHER METAL
 FRAME OR DRYWALL WITH BEADS AND DRYWALL MUD.
 1ST ROUND OF COMMENTS. THIS COMMENT FOR 540 & 580 ALL
 FLOORS AND UNITS. THE AIR HANDLER/ WATER HEATER CLOSET
 SHEET M-200 SHOWS THE REPLACEMENT OF AIR HANDLER, A
 VERTICAL UNIT W/ WATER HEATER BELOW. SHEET A200 NOTE 7
 STATES TO REPLACE THE WATER HEATER. SHEET A200 DOOR FOR
 THE MECHANICAL CLOSET IS LABELED DOOR TYPE 7. SHEET
 A-900 DOOR AND WINDOW SCHEDULE DOOR TYPE 7 IS A WOOD
 LOUVERED BI-FOLD DOOR. SINCE THERE IS NO DIRECT RETURN,
 THE SPACE WITHIN THE MECHANICAL CLOSET IS CONSIDERED A
 PLENUM, NO COMBUSTIBLES ARE ALLOWED IN A PLENUM. PLEASE
 REVIEW IN THE 2020 FBC-MECHANICAL CODE SECTIONS 602.2
 CONSTRUCTION & 602.2.1 MATERIALS WITHIN PLENUMS. METAL
 BI-FOLD DOORS ARE ACCEPTABLE.
  
 6B) SEMI-COMPLIED. SHEET A-203. THE MECHANICAL CLOSET
 VERTICAL A/C AIR HANDLER AND WATER HEATER TO BE
 REPLACED. DOOR TO MECHANICAL CLOSET IS IDENTIFIED AS
 #8. SHEET A-900 TYPE F IS A WOOD HOLLOW CORE BI-FOLD
 DOOR. SINCE THERE IS NO DIRECT RETURN, THE SPACE WITHIN
 THE MECHANICAL CLOSET IS CONSIDERED A PLENUM, NO
 COMBUSTIBLES ARE ALLOWED IN A PLENUM. PLEASE REVIEW IN
 THE 2020 FBC-MECHANICAL CODE SECTIONS 602.2
 CONSTRUCTION & 602.2.1 MATERIALS WITHIN PLENUMS. METAL
 BI-FOLD DOORS ARE ACCEPTABLE. PLEASE ALSO NOTE THAT THE
 VERTICAL AIR HANDLER WOULD HAVE TO SIT ON A METAL STAND
 NOT WOOD FRAMING.
  
 7) SHEET A-204 COMMON AREA ENLARGED FLOOR PLAN AND
 ELEVATIONS 2020 FBC-ACCESSIBILITY CODE:
  
 7A-B) COMPLIED.
  
 7C) 2ND REQUEST, DRAINPIPES NOT SHOWN, WALL HUNG
 LAVATORY DOES NOT SHOW WASTE PIPES NOR 606.5 EXPOSED
 PIPES AND SURFACES. WATER SUPPLY & DRAINPIPES UNDER
 LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
 CONFIGURED TO PROTECT AGAINST CONTACT.
  
 7D-F) COMPLIED.
  
 8) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-17 Cont ID  
Sent By dbattles Date 2023-03-17 Time 10:23 Rev Time 0.00
Received By dbattles Date 2023-03-17 Time 10:23 Sent To  
Notes
2023-03-17 10:33:26 THESE ARE REPAET COMMENTS FROM AND DRAWINGS TO BE
 RESUBMITTED UNDER
  W. P. B. PERMIT: 22101425
  ADD: 550, 580 EXECUTIVE CENTER DR.
  
  W. P. B. PERMIT: 22101430
  ADD: 540 EXECUTIVE CENTER DR.
  
  CONT: LEGACY CONSTRUCTION SERVICES, INC.
  TEL: 216-297-2170
  E-MAIL: [email protected]
  
  2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
  AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
  ADMINISTRATION
  
  2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
  CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
  SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
  BUILDING CODE, BUILDING.
  
  1ST REVIEW
  DATE: WED. JAN. 25/2023
  ACTION: DENIED
  
  1) COMPLIED. PERMIT 22101425. SHEET G103 BUILDING CODE
  DATA, LEASING / COMMUNITY OFFICE FLOOR PLAN.
  
  
  2) COMPLIED.
  
  3) COMPLIED. SHEET A900. 2020 FBC-B 1603.1.4 WIND
  DESIGN CRITERIA.
  
  4A) SEMI-COMPLIED. IN THE FILE FOLDER THE PGT PATIO
  DOORS DID-NOT LOAD.
  SHEET 540 & 580 FLOOR PLANS. NOTE # 1 REMOVE AND
  REPLACE VINYL WINDOWS AND EXTERIOR DOORS. NOTE # 5 TO
  REMOVE & REPLACE ALL EXTERIOR DOORS. COMPONENTS &
  CLADDING. PLEASE SUBMIT THE COMPONENTS AND CLADDING
  PRODUCT APPROVALS. 2020 FBC-B 1609.1.2 PROTECTION OF
  OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
  DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE
  61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY
  OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
  PRODUCT APPROVALS:
  (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
  PGT PATIO DOORS DID NOT LOAD, WILL NOT OPEN FOR REVIEW
  NO EXTERIOR SWING DOORS WERE SUBMITTED.
  (B) WINDOWS & MULLIONS
  PGT HORIZONTAL ROLLERS NOA-20-0406.01 THE NOA IS NOT
  HIGHLIGHTED AS REQUESTED COMMENT 4F.
  PGT SINGLE HUNG WINDOW NOA 20-0401.03 IS NOT
  HIGHLIGHTED AS REQUESTED COMMENT 4F.
  SHEET A-900 DETAILS 8 & 9 SHOW WINDOWS BUT THEY DO NOT
  STATE IF THEY ARE HORIZONTAL SLIDERS OR 2 SINGLE HUNG
  WINDOWS REQUIRING MULLIONS.
  (C) STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, EFIS
  SYSTEMS,
  
  4B) 2ND REQUEST. W. P. B. 107.3.4. PRODUCT APPROVALS.
  THOSE PRODUCTS WHICH ARE REGULATED BY FLORIDA
  ADMINISTRATIVE CODE RULE 61G20 SHALL BE REVIEWED AND
  APPROVED IN WRITING (SHOP DRAWING STAMP OF APPROVAL)
 BY
  THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
  JURISDICTIONAL APPROVAL.
  FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
  SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
  SHOP DRAWINGS ETC.
  
  4C) NOTICE ONLY: DELEGATED ENGINEERING. 61G15-30.003
  ENGINEERING DOCUMENT CLASSIFICATION. FL 61G-15-30.006
  (3) THE DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
  ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
  REVIEW.
  
  4D) NON-COMMENT SUBMITTED COMPONENT & CLADDING PRODUCT
  APPROVALS. 107.3.4.2 DEFERRED SUBMITTALS. FOR THE
  PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
  DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
  SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
  TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
  SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS
 SHALL
  HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
  REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
  SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
  DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
  
  DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
  SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
  RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
  THEM TO THE BUILDING OFFICIAL WITH A NOTATION
  INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
  BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE
 TO
  THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
  ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
  SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
  OFFICIAL.
  
  4E) 2ND REQUEST, PGT PATIO DOOR PRODUCT APPROVAL DID
  NOT OPEN WILL NEED REVIEW FOR PRESSURES AND SILL
  HEIGHT, FOR POSITIVE PRESSURES.
  1ST ROUND OF COMMENTS. 2020 FBC-B 1709.5.1 HABITAT
  SPACES, WATER INTRUSION. EXTERIOR DOORS AND WINDOWS.
  EXCEPTION # 2. SILL LIMITING FACTOR.
  
  4F) 2ND REQUEST. IDENTIFY GLAZING/ MULLIONS. PLEASE
  IDENTIFY IN THE PRODUCT APPROVAL BEFORE SUBMITTING TO
  DESIGNER OF RECORD AND BEFORE SUBMISSION TO THE
  BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING,
  PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, SILL
  HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
  UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
  ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
  SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
  DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
  MANUFACTURER???S INSTRUCTIONS. FASTENER SIZE AND
  SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND
  SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING
  USED IN THE TESTS.
  
  5) COMPLIED NOT APPLICABLE.
  
  6A) SEMI-COMPLIED.A-900 DOOR SCHEDULE NOW SHOWS METAL
  LOUVER DOOR BUT STILL HAS WOOD FRAME, EITHER METAL
  FRAME OR DRYWALL WITH BEADS AND DRYWALL MUD.
  1ST ROUND OF COMMENTS. THIS COMMENT FOR 540 & 580 ALL
  FLOORS AND UNITS. THE AIR HANDLER/ WATER HEATER CLOSET
  SHEET M-200 SHOWS THE REPLACEMENT OF AIR HANDLER, A
  VERTICAL UNIT W/ WATER HEATER BELOW. SHEET A200 NOTE 7
  STATES TO REPLACE THE WATER HEATER. SHEET A200 DOOR
 FOR
  THE MECHANICAL CLOSET IS LABELED DOOR TYPE 7. SHEET
  A-900 DOOR AND WINDOW SCHEDULE DOOR TYPE 7 IS A WOOD
  LOUVERED BI-FOLD DOOR. SINCE THERE IS NO DIRECT
 RETURN,
  THE SPACE WITHIN THE MECHANICAL CLOSET IS CONSIDERED A
  PLENUM, NO COMBUSTIBLES ARE ALLOWED IN A PLENUM.
 PLEASE
  REVIEW IN THE 2020 FBC-MECHANICAL CODE SECTIONS 602.2
  CONSTRUCTION & 602.2.1 MATERIALS WITHIN PLENUMS. METAL
  BI-FOLD DOORS ARE ACCEPTABLE.
  
  6B) SHEET A-203. THE MECHANICAL CLOSET VERTICAL A/C
 AIR
  HANDLER AND WATER HEATER TO BE REPLACED. DOOR TO
  MECHANICAL CLOSET IS IDENTIFIED AS #8. SHEET A-900
 TYPE
  F IS A WOOD HOLLOW CORE BI-FOLD DOOR. SINCE THERE IS
 NO
  DIRECT RETURN, THE SPACE WITHIN THE MECHANICAL CLOSET
  IS CONSIDERED A PLENUM, NO COMBUSTIBLES ARE ALLOWED IN
  A PLENUM. PLEASE REVIEW IN THE 2020 FBC-MECHANICAL
 CODE
  SECTIONS 602.2 CONSTRUCTION & 602.2.1 MATERIALS WITHIN
  PLENUMS. METAL BI-FOLD DOORS ARE ACCEPTABLE. PLEASE
  ALSO NOTE THAT THE VERTICAL AIR HANDLER WOULD HAVE TO
  SIT ON A METAL STAND NOT WOOD FRAMING.
  
  7) SHEET A-204 COMMON AREA ENLARGED FLOOR PLAN AND
  ELEVATIONS 2020 FBC-ACCESSIBILITY CODE:
  
  7A) 2ND REQUEST. DETAILS 4 & 10 PLEASE REVIEW TOILET
  PAPER DISPENSERS. 604.7. THE TOILET PAPER DISPENSER
  SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM
  TO 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
  MEASURED TO THE CENTERLINE OF THE DISPENSER.
  
  7B) 2ND REQUEST. THE SIDE GRAB BARS ARE NOT
 DIMENSIONED
  FROM THE CORNER WALL. 2020 FBC-ACCESSIBILITY CODE
  SECTION 604.5.1 THE SIDE WALL GRAB BAR SHALL BE 42
  INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM
 THE
  REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE
 REAR
  WALL.
  
  7C) 2ND REQUEST, DRAINPIPES NOT SHOWN, WALL HUNG
  LAVATORY DOES NOT SHOW WASTE PIPES NOR 606.5 EXPOSED
  PIPES AND SURFACES. WATER SUPPLY & DRAINPIPES UNDER
  LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
  CONFIGURED TO PROTECT AGAINST CONTACT.
  
  7D) COMPLIED. DETAIL # 12 THE KITCHENETTE SHOWS THE
  HEIGHT TO THE TOP OF THE BACK SPLASH TO BE 2FEET 10
  INCHES, NOT TO THE COUNTERTOP. SINKS> 2020
  FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT.
 LAVATORIES
  AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE
  HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM
  ABOVE THE FINISH FLOOR OR GROUND.
  
  7E)2ND REQUEST. FLOOR PLAN IS MISSING THE REQUIRED
  CLEAR FLOOR SPACE. 606.2 CLEAR FLOOR SPACE. A CLEAR
  FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A
  FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING
  WITH 306 SHALL BE PROVIDED, SEE EXCEPTIONS ALSO, BUT
  SHOW THE REQUIRED CLEAR FLOOR SPACE ON THE FLOOR PLAN.
  
  7F) THE FLOOR PLAN SHOWS A SINGLE DRINKING FOUNTAIN.
  THE 2020 EXISTING BUILDING CODE LEVEL I, LEVEL 2 OR
  LEVEL 3 ALL REFER YOU TO THE 2020 FBC-ACCESSIBILITY
  CODE. FLORIDA ACCESSIBILITY CODE SECTION:
  DISPROPORTIONATE COST 202.4.1. PART OF THE UPGRADES
  WOULD INCLUDE:
  
  7F)(1-2) COMPLIED.
  7F)(3) 2ND REQUEST. 602.2 CLEAR FLOOR SPACE. A CLEAR
  FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A
  FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING
  WITH 306 SHALL BE PROVIDED.
  
  7F)(4) 2ND REQUEST. SPOUT OUTLETS/ DRINKING FOUNTAINS.
  2017 ACCESS. CODE. SPOUT OUTLETS SHALL COMPLY WITH:
  602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
  FLOOR OR GROUND FOR WHEELCHAIR BOUND
  INDIVIDUALS.
  602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
  BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
  8) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
  ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
  THE REVISION MADE, IDENTIFYING THE SHEET OR
  SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
  HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
  ANTICIPATED COOPERATION.
  
  PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
  REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
  REVIEW CYCLE.
  PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
  REVIEW, SUBSEQUENT
  REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
  MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30
 PM
  PART-TIME/ SEMI-RETIRED.
  
  IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I
 GET
  BACK INTO THE OFFICE CALL
  (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
  THANK YOU.
  
  JAMES A. WITMER BN, PX, SFP, CBO
  SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
  CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
  DEPARTMENT
  401 CLEMATIS ST. WEST PALM BEACH. FL 33402
  TEL: 561-805-6717
  FAX: 561-805-6676
  E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-13 Cont ID  
Sent By jwitmer Date 2023-02-13 Time 10:52 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2023-02-13 10:52:11WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22101430
 ADD: 540 EXECUTIVE CENTER DR.
  
  
 W. P. B. PERMIT: 22101425
 ADD: 550, 580 EXECUTIVE CENTER DR.
 CONT: LEGACY CONSTRUCTION SERVICES, INC.
 TEL: 216-297-2170
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JAN. 25/2023 SAME PLAN MON. FEB. 13TH/
 2023
 ACTION: DENIED
  
 1) PERMIT 22101425. SHEET G103 BUILDING CODE DATA,
 LEASING / COMMUNITY OFFICE FLOOR PLAN:
  
 1A) NOTE # 5. LIST FIRE RESISTANCE RATINGS, BUT NONE IS
 PROVIDED FOR ROOMS SUCH AS FIRE PUMP ROOM, TRASH CHUTE
 ELEVATOR MACHINE ROOMS, ETC.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITY TO
 INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 1B) BUILDING 540 & 580. NOTE # 7. WASTE HANDLING, N/A.
 PLEASE PROVIDE AN EXPLANATION SINCE THE MASTER PLAN
 WHEN BUILT SHOWS A 2-HOUR SHAFT FOR TRASH CHUTE, ACCESS
 ROOM AND THE FIRST FLOOR A TRASH TERMINATION ROOM AS
 WELL AS ELEVATOR MACHINE ROOM, WHICH ARE ALL MISSING.
 713.13.4 OF THE 2020 FBC-BUILDING CODE.
  
 1C) PLEASE NOTE THESE PERMITS ARE FOR THE REMODELING OF
 THE (2) BUILDINGS ONLY. SEPARATE PERMITS ARE REQUIRED
 FOR RESURFACING& STRIPING OF THE PARKING LOT, FENCES,
 AWNINGS, SIGNS, GENERATOR, POOL AND OR DECK INCLUSIVE
 OF EQUIPMENT IF SAME CONTRACTOR, DUMPSTER ENCLOSURE,
 IRRIGATION, LANDSCAPE, FIRE SPRINKLERS AND OR FIRE
 ALARM.
  
 2) PERMIT 22101425. SHEET A-105 WAS LOADED WRONG, THERE
 IS A BLANK SHEET. 2020 WEST PALM BEACH AMENDMENTS TO
 THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.
 CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITY TO
 INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 3) SHEET A100 540 FLOOR PLAN & A103 580. NOTE # 1
 REMOVE AND REPLACE VINYL WINDOWS THROUGH OUT NEW
 WINDOWS TO MEET HURRICANE REQUIREMENTS. THERE ARE NO
 STRUCTURAL SHEETS PROVIDING THE FOLLOWING INFORMATION.
 2020 FBC-B 1603.1.4 WIND DESIGN CRITERIA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 3.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 3.7) 2020 FBC-B 1709.5.1 HABITAT SPACES, WATER
 INTRUSION. EXTERIOR DOORS AND WINDOWS. EXCEPTION # 2.
 SILL LIMITING FACTOR.
  
 4A) SHEET 540 & 580 FLOOR PLANS. NOTE # 1 REMOVE AND
 REPLACE VINYL WINDOWS AND EXTERIOR DOORS. NOTE # 5 TO
 REMOVE & REPLACE ALL EXTERIOR DOORS. COMPONENTS &
 CLADDING. PLEASE SUBMIT THE COMPONENTS AND CLADDING
 PRODUCT APPROVALS. 2020 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE
 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY
 OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, EFIS
 SYSTEMS,
  
 4B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 4C) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 4D) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 4E) 2020 FBC-B 1709.5.1 HABITAT SPACES, WATER
 INTRUSION. EXTERIOR DOORS AND WINDOWS. EXCEPTION # 2.
 SILL LIMITING FACTOR.
  
 4F) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE
 OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER???S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 5) SHEET A103- FLOOR PLAN 580 (2) UNITS ARE IN GRAY BUT
 THERE ARE NO NOTES PLEASE EXPLAIN. 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.2.1. CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 6A) THIS COMMENT FOR 540 & 580 ALL FLOORS AND UNITS.
 THE AIR HANDLER/ WATER HEATER CLOSET SHEET M-200 SHOWS
 THE REPLACEMENT OF AIR HANDLER, A VERTICAL UNIT W/
 WATER HEATER BELOW. SHEET A200 NOTE 7 STATES TO REPLACE
 THE WATER HEATER. SHEET A200 DOOR FOR THE MECHANICAL
 CLOSET IS LABELED DOOR TYPE 7. SHEET A-900 DOOR AND
 WINDOW SCHEDULE DOOR TYPE 7 IS A WOOD LOUVERED BI-FOLD
 DOOR. SINCE THERE IS NO DIRECT RETURN, THE SPACE WITHIN
 THE MECHANICAL CLOSET IS CONSIDERED A PLENUM, NO
 COMBUSTIBLES ARE ALLOWED IN A PLENUM. PLEASE REVIEW IN
 THE 2020 FBC-MECHANICAL CODE SECTIONS 602.2
 CONSTRUCTION & 602.2.1 MATERIALS WITHIN PLENUMS. METAL
 BI-FOLD DOORS ARE ACCEPTABLE.
  
 6B) SHEET A-203. THE MECHANICAL CLOSET VERTICAL A/C AIR
 HANDLER AND WATER HEATER TO BE REPLACED. DOOR TO
 MECHANICAL CLOSET IS IDENTIFIED AS #8. SHEET A-900 TYPE
 F IS A WOOD HOLLOW CORE BI-FOLD DOOR. SINCE THERE IS NO
 DIRECT RETURN, THE SPACE WITHIN THE MECHANICAL CLOSET
 IS CONSIDERED A PLENUM, NO COMBUSTIBLES ARE ALLOWED IN
 A PLENUM. PLEASE REVIEW IN THE 2020 FBC-MECHANICAL CODE
 SECTIONS 602.2 CONSTRUCTION & 602.2.1 MATERIALS WITHIN
 PLENUMS. METAL BI-FOLD DOORS ARE ACCEPTABLE.
  
 7) SHEET A-204 COMMON AREA ENLARGED FLOOR PLAN AND
 ELEVATIONS 2020 FBC-ACCESSIBILITY CODE:
  
 7A) DETAILS 4 & 10 PLEASE REVIEW TOILET PAPER
 DISPENSERS. 604.7. THE TOILET PAPER DISPENSER SHALL
 COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM TO 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 7B) THE SIDE GRAB BARS ARE NOT DIMENSIONED FROM THE
 CORNER WALL. 2020 FBC-ACCESSIBILITY CODE SECTION
 604.5.1 THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL
 AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL.
  
 7C) WALL HUNG LAVATORY DOES NOT SHOW WASTE PIPES NOR
 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY &
 DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
  
 7D) DETAIL # 12 THE KITCHENETTE SHOWS THE HEIGHT TO THE
 TOP OF THE BACK SPLASH TO BE 2FEET 10 INCHES, NOT TO
 THE COUNTERTOP. SINKS> 2020 FBC-ACCESSIBILITY CODE
 SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE
 INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR
 COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 7E) FLOOR PLAN IS MISSING THE REQUIRED CLEAR FLOOR
 SPACE. 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED, SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED
 CLEAR FLOOR SPACE ON THE FLOOR PLAN.
  
 7F) THE FLOOR PLAN SHOWS A SINGLE DRINKING FOUNTAIN.
 THE 2020 EXISTING BUILDING CODE LEVEL I, LEVEL 2 OR
 LEVEL 3 ALL REFER YOU TO THE 2020 FBC-ACCESSIBILITY
 CODE. FLORIDA ACCESSIBILITY CODE SECTION:
 DISPROPORTIONATE COST 202.4.1. PART OF THE UPGRADES
 WOULD INCLUDE:
  
 7F)(1) 2020 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM
 NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE
 PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1
 THROUGH 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY
 WITH 602.7.
  
 7F)(2) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS
 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES
 AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT
 PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE
 CIRCULATION PATH.
  
 7F)(3) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 7F)(4)SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND FOR WHEELCHAIR BOUND
 INDIVIDUALS.
 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
 BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 8) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-03-16 Cont ID  
Sent By mpeterso Date 2023-03-16 Time 13:30 Rev Time 0.00
Received By mpeterso Date 2023-03-16 Time 13:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-13 Cont ID  
Sent By rperdomo Date 2023-02-13 Time 11:12 Rev Time 0.00
Received By rperdomo Date 2023-02-13 Time 11:00 Sent To  
Notes
2023-02-13 11:12:44FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE INFORMATION OR SPECIFICATIONS OF NEW
 EQUIPMENT (WATER HEATERS, ELECTRIC AIR HANDLERS, SMOKE
 ALARMS, EXHAUST FAN , ETC). FBC 107.2
 2. PROVIDE INFORMATION OF EXISTING ELECTRICAL PANEL AND
 PROTECTION (INCLUDING PANEL SCHEDULE). NEC 240, 408,
 408.4(A)
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-02-13 Cont ID  
Sent By rrossano Date 2023-02-13 Time   Rev Time 0.00
Received By rrossano Date 2023-02-13 Time   Sent To  
Notes
2023-03-03 12:20:13PASSED FOR BUILDING DEMO.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-03-10 Cont ID  
Sent By cwalker Date 2023-03-10 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-02-14 Cont ID  
Sent By   Date 2023-02-14 Time   Rev Time 0.00
Received By jcclark Date 2023-02-14 Time 07:20 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2023-03-10 Cont ID  
Sent By ccole Date 2023-03-10 Time 10:40 Rev Time 0.00
Received By ccole Date 2023-03-10 Time 09:42 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By ccole Date 2023-01-03 Time 11:58 Rev Time 0.00
Received By ccole Date 2023-01-03 Time 11:58 Sent To  
Notes
2023-01-03 12:00:281ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22101425, 22101430
 1/3/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P202: PLEASE PROVIDE THE BTU CAPACITY OF THE
 EXISTING AND NEW GAS WATER HEATERS TO VERIFY THE
 LIKE-FOR-LIKE REPLACEMENT- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-03-22 Cont ID  
Sent By vbroglia Date 2023-03-22 Time 15:51 Rev Time 0.00
Received By vbroglia Date 2023-03-21 Time 07:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-17 Cont ID  
Sent By dbattles Date 2023-03-17 Time 10:33 Rev Time 0.00
Received By dbattles Date 2023-03-09 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-09 Cont ID  
Sent By avolcy Date 2023-03-09 Time 11:56 Rev Time 0.00
Received By rmcdouga Date 2022-12-19 Time 13:00 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2023-02-13 Cont ID  
Sent By jwitmer Date 2023-02-13 Time 10:52 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-03-10 Cont ID  
Sent By medwards Date 2023-03-10 Time 09:02 Rev Time 0.00
Received By medwards Date 2023-03-10 Time 09:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-12-27 Cont ID  
Sent By medwards Date 2022-12-27 Time 16:39 Rev Time 0.00
Received By medwards Date 2022-12-27 Time 16:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-03-21 Cont ID  
Sent By ccole Date 2023-03-21 Time 15:39 Rev Time 0.00
Received By ccole Date 2023-03-21 Time 15:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-03-10 Cont ID  
Sent By ccole Date 2023-03-10 Time 10:39 Rev Time 0.00
Received By ccole Date 2023-03-10 Time 09:42 Sent To  
Notes
2023-03-10 10:39:582ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22101425, 22101430
 3/10/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P202: SHOW THE NEW DRINKING FOUNTAIN DRAIN AND
 VENT PIPE RUNS ON THE PLANS AND PROVIDE A SANITARY
 RISER DRAWING- SECS. 107.2.1 & 107.3.5.1.3 WPB.
  
 2) SHEET A204: THE REVISED SHEET SHOWS NEW ACCESSIBLE
 DRINKING FOUNTAINS ON THE EXTERIOR OF THE BUILDING THAT
 APPEAR TO BE PROTRUDING OBJECTS IN THE CIRCULATION
 PATH- SEE SEC. 307.2 FBC ACC. IT APPEARS THE FOUNTAINS
 WILL HAVE TO BE RELOCATED AND RECESSED IN A NICHE, OR
 GUARDS WILL HAVE TO BE INSTALLED AT THE CURRENT
 LOCATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-03 Cont ID  
Sent By ccole Date 2023-01-03 Time 11:57 Rev Time 0.00
Received By ccole Date 2023-01-03 Time 11:56 Sent To  
Notes
2023-01-03 11:57:231ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22101425, 22101430
 1/3/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A204: PLEASE CORRECT THE DETAILS IN ACCORDANCE
 WITH THE FOLLOWING FBC ACC CODE SECTIONS.
 A) SHOW THE CENTERLINES OF THE WATER CLOSETS FROM THE
 SIDE WALLS- SEC. 604.2.
 B) SHOW THE HEIGHTS OF THE WATER CLOSET SEATS FROM THE
 FINISHED FLOORS- SEC. 604.4.
 C) SHOW THE WATER CLOSET GRAB BAR LOCATIONS IN
 COMPLIANCE WITH SECS. & FIGURES 604.5.1 & 604.5.2. THE
 DETAILS DO NOT SHOW THE SPACINGS FROM THE ADJACENT
 WALLS, THE SIDE WALL GRAB BAR MINIMUM LENGTH FROM THE
 ADJACENT WALL, AND THE 12-INCH CENTERING LOCATION FOR
 THE REAR GRAB BAR.
 D) SHOW THE CENTERLINES OF THE TOILET PAPER DISPENSERS
 MINIMUM 7 INCHES AND 9-INCHES MAXIMUM MEASURED FROM THE
 FRONT LEADING EDGE OF THE WATER CLOSETS- SEC. AND
 FIGURE 604.7.
 E) SHOW THE KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SEC. 606.2.
 F) SHOW THE URINAL MAXIMUM HEIGHT ABOVE THE FINISHED
 FLOOR, AND THE MINIMUM DEPTH OF MEASURED FORM THE OUTER
 FACE TO THE BACK OF THE FIXTURE- SEC. 605.2.
  
 2) SHEET P202: IT APPEARS THE SCHEDULE DOESN'T INCLUDE
 SPECIFICATIONS FOR THE ADA COMPLIANT WATER CLOSETS IN
 THE LEASING CENTER. THE PLANS SHOW WC1 BE INSTALLED IN
 BOTH THE LEASING CENTER AND DWELLING UNIT BATHROOMS-
 SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-03-21 Cont ID  
Sent By ccole Date 2023-03-21 Time 15:40 Rev Time 0.00
Received By ccole Date 2023-03-21 Time 15:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-16 Cont ID  
Sent By mpeterso Date 2023-03-16 Time 13:30 Rev Time 0.00
Received By mpeterso Date 2023-03-16 Time 13:30 Sent To  
Notes
2023-03-16 13:30:52ALL PLANS PASSED SIGNATURE REVIEW.
2023-03-10 10:56:18PLUMBING PLANS PASSED.
2023-03-10 09:03:17MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-03-09 Cont ID  
Sent By rmcdouga Date 2023-03-09 Time 11:56 Rev Time 0.00
Received By rmcdouga Date 2023-03-09 Time 11:56 Sent To  
Notes
2023-02-13 10:55:44ARCHITECTURAL SHEETS DIGITAL SIGNATURE IS OK. J WITMER
 2/13/2023
2022-12-27 16:39:42MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2023-03-22 Cont ID  
Sent By vbroglia Date 2023-03-22 Time 15:51 Rev Time 0.00
Received By vbroglia Date 2023-03-22 Time 15:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-03-17 Cont ID  
Sent By vbroglia Date 2023-03-17 Time 09:31 Rev Time 0.00
Received By vbroglia Date 2023-03-17 Time 09:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By AVolcy Date 2023-03-08 Time 14:32 Rev Time 0.00
Received By avolcy Date 2023-03-08 Time 14:32 Sent To  
Notes
2023-03-08 14:32:163/8/23 - FAILED
  
 THE VALUE OF THE CONSTRUCTION ($3.7M) EXCEEDS 50% OF
 THE STRUCTURE'S VALUE ($5.5M) ACCORDING TO THE P.B.C.
 PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT TO
 SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. SUBMIT A SEPARATE LANDSCAPE
 PERMIT WITH PLANS SHOWING MATERIAL EXISTING ON SITE OR
 ANY ADDITION OF TREES OR SHRUBS TO BRING THE SITE INTO
 CONFORMITY.
  
 SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE,
 IRRIGATION, LANDSCAPE, OTHER.
  