Plan Review Details - Permit 22101422
Plan Review Stops For Permit 22101422
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-01-06 Cont ID  
Sent By jbrooks Date 2023-01-06 Time 13:01 Rev Time 0.00
Received By jbrooks Date 2023-01-06 Time 07:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-27 Cont ID  
Sent By jbrooks Date 2022-12-27 Time 08:26 Rev Time 0.00
Received By jbrooks Date 2022-12-27 Time 08:17 Sent To  
Notes
2022-12-27 08:26:30JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY
 CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA
 REGISTERED PROFESSIONAL ENGINEER; TO THE CORRECT
 PROPERTY ADDRESS 304 PILGRIM RD INCLUDING CORRECT
 BACKGROUND INFORMATION: PCN#, BUILDING TYPE, YEAR
 BUILT, ROOF HEIGHT. INFORMATION DOES NOT MATCH PERMIT
 #22101422.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-12-20 Cont ID  
Sent By jbrooks Date 2022-12-20 Time 13:31 Rev Time 0.00
Received By jbrooks Date 2022-12-20 Time 08:03 Sent To  
Notes
2022-12-20 13:31:49JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. PROVIDE THE FOLLOWING INFORMATION FOR MIAMI-DADE NOA
 NO.: 20-0131.01 FOR THE PROPOSED FLAT ROOF SYSTEM TO BE
 USED CORRESPONDING TO ENGINEERS CALCULATIONS. COVER
 PAGE #1, INSTALLATION INSTRUCTIONS FOR SYSTEM E (2)
 PAGE(S) #12 AND LIMITATIONS PAGE(S) #18. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS.
 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE. SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-07 Cont ID  
Sent By jbrooks Date 2022-11-07 Time 12:19 Rev Time 0.00
Received By jbrooks Date 2022-11-07 Time 12:09 Sent To  
Notes
2022-11-07 12:19:56JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-2;
 EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15);
 ULTIMATE WIND SPEED (170). ZONE 3 IS MARKED ???N/A???
 WHICH INDICATES SYSTEM CANNOT BE USED WITHIN THE
 PRESSURE ZONE. PLEASE SELECT THE CORRECT SYSTEM &
 OPTIONS.
 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2022-11-07 Cont ID  
Sent By jbrooks Date 2022-11-07 Time 12:20 Rev Time 0.00
Received By jbrooks Date 2022-12-20 Time 13:34 Sent To  
Notes
2022-11-07 12:20:36*FLAT ROOF ONLY*

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-01-06 Cont ID  
Sent By jbrooks Date 2023-01-06 Time 13:01 Rev Time 0.00
Received By jbrooks Date 2023-01-04 Time 14:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-28 Cont ID  
Sent By medwards Date 2022-12-28 Time 12:40 Rev Time 0.00
Received By medwards Date 2022-12-21 Time 16:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-20 Cont ID  
Sent By jbrooks Date 2022-12-20 Time 13:31 Rev Time 0.00
Received By jbrooks Date 2022-12-17 Time 18:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-07 Cont ID  
Sent By jbrooks Date 2022-11-07 Time 12:20 Rev Time 0.00
Received By jbrooks Date 2022-11-07 Time 08:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-01-06 Cont ID  
Sent By jbrooks Date 2023-01-06 Time 13:01 Rev Time 0.00
Received By jbrooks Date 2023-01-06 Time 07:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-12-28 Cont ID  
Sent By medwards Date 2022-12-28 Time 12:39 Rev Time 0.00
Received By medwards Date 2022-12-28 Time 12:39 Sent To  
Notes
2022-12-28 12:40:34THE ENGINEERS SEAL WILL NEED TO BE SUBMITTED AS A
 DIGITAL SIGNATURE. FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-12-20 Cont ID  
Sent By jbrooks Date 2022-12-20 Time 13:30 Rev Time 0.00
Received By jbrooks Date 2022-12-20 Time 13:30 Sent To  
Notes
2022-12-20 13:31:05JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE
 UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO
 PROJECTDOX
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED
 PLAN/DOCUMENT TO PROJECTDOX
 PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO
 LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH
 BUILDING DEPRTMENT.
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  


Account Summary | Usage Policy | Privacy Policy