Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-17 Cont ID  
Sent By jgomez Date 2022-11-17 Time 16:34 Rev Time 0.00
Received By jgomez Date 2022-11-17 Time 16:29 Sent To  
Notes
2022-11-17 16:37:28TALKED TO HENRY ROQUE. USING TWO PADDY ADHESIVE WITH 8
 GRAMS PER PADDY. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-16 Cont ID  
Sent By jgomez Date 2022-11-16 Time 19:17 Rev Time 0.00
Received By jgomez Date 2022-11-16 Time 18:11 Sent To  
Notes
2022-11-16 19:18:24RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22101219
 3311 POINSETTIA AVE
  
 1- POLYGLASS POLYSTICK UNDERLAYMENT (NOA 21-1217.02)
 DOESN'T LIST THE TILE BOND ROOF TILE ADHESIVE (NOA
 21-1006.03) AS APPROVED ADHESIVE TO BE USED WITH THIS
 UNDERLAYMENT. PROVIDE UNDERLAYMENT LISTING THE TILE
 BOND ADHESIVE.
 FAC 61G20.3.001
  
 2- HIP AND RIDGE INSTALLATION: PROVIDE COMPLETE DETAILS
 AND SPECIFICATIONS FOR HIP AND RIDGE INSTALLATION AS
 REQUIRED BY SEC. R905.3.7.1 FBC-RESIDENTIAL. SPECIFY
 STRUCTURAL SUPPORT MATERIAL AND PROVIDE PRODUCT
 APPROVAL AS REQUIRED.
 NOTE: CLEARLY MARK ON PRODUCT APPROVAL ATTACHMENT
 METHOD.
  
 3- ROOF TILE NOA 22-0714.17 AND ROOF TILE ADHESIVE
 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE TO BE USED
 AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 4- RAS 117 CALCULATIONS NEED THE ORIGINAL SEAL AND
 SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR
 PUBLIC RECORDS.
 NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH
 ENGINEER'S VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD
 COPY WITH ORIGINAL SEAL/SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-11-16 Cont ID  
Sent By amhamilt Date 2022-11-16 Time 12:17 Rev Time 0.00
Received By amhamilt Date 2022-11-16 Time 12:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-11-18 Cont ID  
Sent By jgomez Date 2022-11-18 Time 09:26 Rev Time 0.00
Received By jgomez Date 2022-11-18 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-18 Cont ID  
Sent By jgomez Date 2022-11-18 Time 09:03 Rev Time 0.00
Received By jgomez Date 2022-11-18 Time 09:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-17 Cont ID  
Sent By jgomez Date 2022-11-17 Time 16:37 Rev Time 0.00
Received By jgomez Date 2022-11-17 Time 13:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-16 Cont ID  
Sent By jgomez Date 2022-11-16 Time 19:19 Rev Time 0.00
Received By jgomez Date 2022-11-16 Time 12:10 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-11-18 Cont ID  
Sent By jgomez Date 2022-11-18 Time 09:26 Rev Time 0.00
Received By jgomez Date 2022-11-18 Time 09:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-11-18 Cont ID  
Sent By jgomez Date 2022-11-18 Time 09:02 Rev Time 0.00
Received By jgomez Date 2022-11-18 Time 09:00 Sent To  
Notes
2022-11-18 09:03:15SIGNATURE REVIEW
  
 1- RAS 117 CALCULATIONS SUBMITTED HAVE A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE
 NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A
 LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE
 DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED
 BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE
 DIGITAL SIGNATURE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-11-17 Cont ID  
Sent By jgomez Date 2022-11-17 Time 16:50 Rev Time 0.00
Received By jgomez Date 2022-11-17 Time 16:50 Sent To  
Notes
2022-11-17 16:50:54SIGNATURE REVIEW:
  
 1-- RAS 117 CALCULATIONS NEED THE ORIGINAL SEAL AND
 SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR
 PUBLIC RECORDS.
 NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH
 ENGINEER'S VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD
 COPY WITH ORIGINAL SEAL/SIGNATURE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-11-16 Cont ID  
Sent By jgomez Date 2022-11-16 Time 19:19 Rev Time 0.00
Received By jgomez Date 2022-11-16 Time 18:46 Sent To  
Notes
2022-11-16 19:19:40SIGNATURE REVIEW:
  
 1-- RAS 117 CALCULATIONS NEED THE ORIGINAL SEAL AND
 SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR
 PUBLIC RECORDS.
 NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH
 ENGINEER'S VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD
 COPY WITH ORIGINAL SEAL/SIGNATURE.