| Plan Review Stops For Permit 22101174 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-18 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-18 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-18 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-18 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2023-01-18 11:58:17 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-30 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-30 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2022-12-30 09:49:49 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE TILE ADHESIVE TO BE USED. THIRD REQUEST. | | | 2. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-15 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-15 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2022-12-15 11:12:57 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL TO BE USED. (FL5374-R6) SECOND | | | REQUEST. | | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE TILE ADHESIVE TO BE USED. SECOND REQUEST. | | | 3. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S), MEAN | | | ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW POSITIVE | | | DRAINAGE. SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-11-17 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-11-17 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2022-11-17 12:57:48 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | | ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT | | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PRODUCT | | | APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY | | | D ENCLOSED AREAS WITHOUT USING INSULATION. | | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL TO BE USED. (FL5374-R6) | | | 3. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE TILE ADHESIVE TO BE USED. | | | 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S), MEAN | | | ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW POSITIVE | | | DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-18 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-13 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-30 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-27 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-15 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-13 |
Time |
06:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-11-17 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-11-16 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-18 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-18 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-01-18 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-01-18 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2023-01-18 11:57:36 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ROOF COVERING ATTACHMENT | | | CALCULATIONS CAN NOT BE THIRD PARTY VERIFIED. | | | FS 668.003. NOTICE: FLORIDA PROFESSIONAL ENGINEERS MAY | | | NOT SELF CERTIFY DIGITAL SIGNATURES AND SEALS. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX | | | THIRD REQUEST. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-30 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-30 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2022-12-30 09:51:56 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ROOF COVERING ATTACHMENT | | | CALCULATIONS CAN NOT BE THIRD PARTY VERIFIED. | | | FS 668.003. NOTICE: FLORIDA PROFESSIONAL ENGINEERS MAY | | | NOT SELF CERTIFY DIGITAL SIGNATURES AND SEALS. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX. SECOND REQUEST. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-12-15 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-12-15 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2022-12-15 10:56:45 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS 668.003. NOTICE: FLORIDA PROFESSIONAL ENGINEERS MAY | | | NOT SELF CERTIFY DIGITAL SIGNATURES AND SEALS. | | | F.A.C. 61G15-23.004 THE DESIGNER OF THE STRUCTURAL | | | SHEETS CANNOT SELF-CERTIFY THEIR DIGITAL SIGNATURE. THE | | | SIGNATURE MUST BE THIRD PARTY VERIFIED. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|