Plan Review Details - Permit 22101147
Plan Review Stops For Permit 22101147
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-01-04 Cont ID  
Sent By rmcphers Date 2023-01-04 Time 09:44 Rev Time 0.00
Received By rmcphers Date 2023-01-04 Time 09:44 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-11-18 Cont ID  
Sent By rmcphers Date 2022-11-18 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2022-11-18 Time 08:31 Sent To  
Notes
2022-11-18 09:05:40PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-01-04 Cont ID  
Sent By rmcphers Date 2023-01-04 Time 09:43 Rev Time 0.00
Received By rmcphers Date 2023-01-04 Time 09:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-18 Cont ID  
Sent By rmcphers Date 2022-11-18 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2022-11-18 Time 08:31 Sent To  
Notes
2022-11-18 09:26:06OFFICE BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE WALL FINISH SURROUNDING THE MOP SINK
 TO COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE).
  
 2) PLEASE SHOW THE HEIGHT OF THE CHECK-IN AND CHECK-OUT
 COUNTER TO COMPLY WITH FBC A 904.4.1PARALLEL APPROACH.
 A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915
 MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM
 ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED
 FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915
 MM) MINIMUM LENGTH OF COUNTER.
  
 3) THE LIFE SAFETY PLAN SHOWS 2 EXITS INTO THE
 REMAINDER OF THE BUILDING - PLEASE SHOW THE
 CONTINUATION OF THE EXIT ACCESS TO THE EXIT DISCHARGE
 OF THE BUILDING. FBC 1028.1 GENERAL.
 EXITS SHALL DISCHARGE DIRECTLY TO THE EXTERIOR OF THE
 BUILDING. THE EXIT DISCHARGE SHALL BE AT GRADE OR SHALL
 PROVIDE A DIRECT PATH OF EGRESS TRAVEL TO GRADE. THE
 EXIT DISCHARGE SHALL NOT REENTER A BUILDING.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-01-06 Cont ID  
Sent By mpeterso Date 2023-01-06 Time 11:15 Rev Time 0.00
Received By mpeterso Date 2023-01-06 Time 11:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-11-21 Cont ID  
Sent By mpeterso Date 2022-11-21 Time 13:04 Rev Time 0.00
Received By mpeterso Date 2022-11-21 Time 13:04 Sent To  
Notes
2022-11-21 13:15:01ELECTRIC REVIEW FAILED
 1) PLEASE STATE ON THE ELECTRICAL SHEETS THE TYPE
 OCCUPANCY EITHER AMBULATORY HEALTH CARE FACILITY,
 NON-AMBULATORY OR OTHER, AS DETERMINED BY THE ENGINEER
 OF RECORD. IF THE OCCUPANCY IS CHARACTERIZED AS
 AMBULATORY THEN PLEASE DETAIL COMPLIANCE WITH THE
 APPLICABLE NEC CODES. FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-04-12 Cont ID  
Sent By mpeterso Date 2023-04-12 Time 09:08 Rev Time 0.00
Received By mpeterso Date 2023-04-12 Time 09:08 Sent To  
Notes
2023-04-12 09:09:02LOW VOLTAGE PASSED FOR VOICE AND DATA WIFI ONLY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-12-28 Cont ID  
Sent By cwalker Date 2022-12-28 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-12-28 10:30:55FIRE PROVISO COMMENTS:
  
 (1) ANY WORK PERFORMED ON ANY LIFE SAFETY SYSTEM (FIRE
 SPRINKLER AND/OR FIRE ALARM) SHALL BE CONDUCTED UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS BY PROPERLY LICENSED
 CONTRACTORS.
  
 (2) ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE
 ALARM) SHALL REMAIN OPERATIONAL DURING ALL PHASES OF
 DEMOLITION AND CONSTRUCTION.
  
  
 (3) ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE
 SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS
 HOURS IN DURATION SHALL REQUIRE THE IMPLEMENTATION OF A
 FIRE WATCH.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-10-26 Cont ID  
Sent By cwalker Date 2022-10-26 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-10-26 13:56:47FIRE REVIEW COMMENTS:
  
 THE PLAN SUBMITTAL WAS REVIEWED BY C. WALKER AND FAILED
 REVIEW FOR THE FOLLOWING:
  
 THE PLAN SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA FIRE PREVENTION CODE, NFPA 101 (LIFE SAFETY
 CODE), CHAPTER 20, NEW AMBULATORY HEALTH CARE
 OCCUPANCIES. NFPA 1, FIRE CODE, 1.14
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-06 Cont ID  
Sent By mpeterso Date 2023-01-06 Time 11:17 Rev Time 0.00
Received By mpeterso Date 2022-12-27 Time 08:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-21 Cont ID  
Sent By mpeterso Date 2022-11-21 Time 13:15 Rev Time 0.00
Received By mpeterso Date 2022-10-25 Time 17:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-01-03 Cont ID  
Sent By medwards Date 2023-01-03 Time 10:08 Rev Time 0.00
Received By medwards Date 2023-01-03 Time 10:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-11-11 Cont ID  
Sent By medwards Date 2022-11-11 Time 08:49 Rev Time 0.00
Received By medwards Date 2022-11-11 Time 08:49 Sent To  
Notes
2022-11-11 08:49:311ST REVIEW FMC
 PERMIT: 22101147
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW ON THE LIFE SAFETY PLAN HOW THIS
 OCCUPANT WILL MEET THE OFFICE SURGERY SUITE OCCUPANCY
 CLASSIFICATION IN FBC 469.3
  
 2) SHEET M-1: IDENTIFY THE ROOM TO THE LEFT OF
 PROCEDURE ROOM 1.
  
 3) SHEET M-1: PROVIDE THE DUCT SIZES AT EACH DUCT. FBC
 107.3.5
  
 4) SHEET M-1: PROVIDE THE REQUIRED SMOKE DUCT DETECTOR
 IN THE NEW AHU. FMC 606.2.2
  
 5) PROVIDE AN OUTDOOR AIR CALCULATIONS FOR EACH SPACE
 IN EACH ZONE. USE THE OCCUPANCY CLASSIFICATION THAT
 MOST CLOSELY RESEMBLES THE USE OF SPACE IN TABLE
 403.3.1.1. FMC 403.3.1.1 AND TABLE 403.3.1.1
  
 6) PROVIDE EXHAUST FANS THAT WOULD MEET THE MINIMUM OF
 70 CFM???S PER WATER CLOSET IF CONTROLLED
 INTERMITTENTLY. FMC TABLE 403.3.1.1 AND FOOTNOTE E
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-01-05 Cont ID  
Sent By ccole Date 2023-01-05 Time 15:42 Rev Time 0.00
Received By ccole Date 2023-01-05 Time 11:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-11-03 Cont ID  
Sent By ccole Date 2022-11-03 Time 16:20 Rev Time 0.00
Received By ccole Date 2022-11-03 Time 14:29 Sent To  
Notes
2022-11-03 16:22:491ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22101147
 11/3/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P-0, P-2 & P-3: PLEASE PROVIDE AN ENLARGED
 WATER PIPING DETAIL FOR THE WATER HEATER SHOWING THE
 NEW RECIRCULATION PUMP AND MASTER THERMOSTATIC MIXING
 VALVE PIPE CONNECTIONS- SECS. 607.1.1 & 607.2.2 FBC P.
 PLEASE NOTE THE MASTER TMV IS MANDATORY.
  
 A) PLEASE SHOW THE LOCATION OF AND TYPE OF THERMAL
 EXPANSION CONTROL DEVICE IN THE WH PIPING DETAIL- SEC.
 607.3 FBC P.
  
 B) PROVIDE THE TYPE AND THICKNESS OF HW PIPE
 INSULATION- TABLE C403.2.10 FBC EC.
  
 2) P0, P-2, P-3: SHOW THE MEANS OF PROVIDING TEMPERED
 WATER DELIVERY FROM THE PUBLIC LAVATORIES- SEC. 419.5
 FBC P. PLEASE NOTE MIXING VALVES USED FOR TEMPERED
 WATER SHALL BE ASSE 1070 APPROVED- SEC. 607.1.2.
  
 3) A-1.0: PLEASE SHOW THE 30X48-INCH CLEAR FLOOR SPACE
 DIAGRAM AT EACH ACCESSIBLE SINK LOCATION- SEC. 606.2
 FBC ACC.
  
 4) A-4.1 ELEV. B: SHOW THE MINIMUM KNEE 27-INCH
 CLEARANCE HEIGHT FROM THE F.F.- FIGURE 306.3 FBC ACC.
  
 5) A-4.3 DET. 2: PLEASE CORRECT THE FOLLOWING ITEMS PER
 THE FBC ACC
  
 A) SHOW THE HEIGHT OF THE GRAB BARS MEASURED TO THE
 TOPS OF THE GRIPPING SURFACES- SEC. 609.4.
  
 B) SHOW THE CENTERLINE OF THE TOILET PAPER DISPENSER IS
 AT 7-9-INCHES MEASURED FROM THE FRONT OF THE WATER
 CLOSETS SEC. 604.7. THE DETAIL DOES NOT SHOW THE
 MEASUREMENT TO THE CENTER OF THE DISPENSER OUTLET.
  
 C) SHOW THE HEIGHTS OF THE MIRRORS FROM THE F.F. TO THE
 REFLECTIVE SURFACES- SEC. 603.3.
  
 6) A-4.1 & A-4.3: SHOW THE CLEAR FLOOR SPACE DIAGRAM AT
 THE ACCESSIBLE DRINKING FOUNTAIN LOCATION- SEC. 602.2
 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-01-04 Cont ID  
Sent By rmcphers Date 2023-01-04 Time 09:43 Rev Time 0.00
Received By rmcphers Date 2023-01-04 Time 09:42 Sent To  
Notes
2023-01-03 10:09:32MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-17 Cont ID  
Sent By rwbrown Date 2022-11-17 Time 07:20 Rev Time  
Received By rwbrown Date   Time   Sent To  
Notes
2022-11-11 08:50:09MECHANICAL DIGITAL SIGNATURES APPROVED ME