Plan Review Details - Permit 22101029
| Plan Review Stops For Permit 22101029 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-12-13 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-12-13 |
Time |
18:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-06 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-06 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-22 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-22 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2022-12-22 13:49:31 | ELECTRIC REVIEW FAILED | | | 1) ORIGINAL RISER INDICATED (6) 1/0 CONDUCTORS FEEDING | | | (2) PANELS. NEW RISER INDICATES ENTIRE LOAD WILL BE | | | HANDLED BY (1) 150-AMP OCP. LOAD CALCULATIONS PROVIDED | | | DO NOT INCLUDE ALL LOADS (HEAT, COOKTOPS ETC.). PLEASE | | | PROVIDE ENTIRE SERVICE LOAD CALCULATIONS. USING EITHER | | | THE STANDARD OR OPTIONAL METHOD,. INCLUDE ALL LOADS, IF | | | LOADS ARE GAS, PLEASE INDICATE THEM AS SO. ALSO PROVIDE | | | COMPLETE PANEL SCHEDULES FOR ALL (3) PANELS, MAIN | | | DISCONNECT PANEL, PANEL A AND B. INCLUDE ALL OVER | | | CURRENT PROTECTION SIZES. NEC 215.5 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-01 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-01 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2022-12-01 08:35:46 | ELECTRIC REVIEW FAILED | | | 1) PLAN INDICATES (6) 1/0 CU CONDUCTORS FROM A 150- AMP | | | MAIN BREAKER PANEL TO A 200-AMP TRANSFER SWITCH THEN TO | | | (2) 150-AMP PANELS. PLEASE PROVIDE ADDITIONAL | | | INFORMATION ON PLAN, SUCH AS WHERE DO ALL CONDUCTORS | | | TERMINATE, WHAT LOADS WILL THE TRANSFER SWITCH FEED, | | | ETC. NEC 215.5 FBC 107.2 | | | | | | 2) IN ADDITION, 1/0 CU CONDUCTOR AMPACITY IS 150- AMPS. | | | THE REDUCTION IN AMPACITY AS PER NEC 310.15 (B)(7)(2) | | | IS NOT APPLICABLE BECAUSE THESE CONDUCTORS DO NOT CARRY | | | THE ENTIRE LOAD TO THE DWELLING. SINCE THERE ARE 6 | | | CONDUCTORS IN THE CONDUIT THE AMPACITY MUST BE REDUCED | | | AS PER NEC TABLE 310.15(B)(3)(A). THESE CONDUCTORS AS | | | SHOWN ARE NOT CODE COMPLIANT. PLEASE REVISE AS | | | APPLICABLE FOR CODE COMPLIANCE | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-07 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-07 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-06 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-28 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-15 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-12-13 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-11-04 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-07 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-07 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-22 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-01 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-01 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-11-21 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-11-21 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy