Plan Review Details - Permit 22100754
Plan Review Stops For Permit 22100754
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2023-06-23 Cont ID  
Sent By cpuell Date 2023-06-23 Time 09:29 Rev Time 0.00
Received By cpuell Date 2023-06-23 Time 09:29 Sent To  
Notes
2023-06-23 09:34:00RECEIVED PRELIMINARY LETTER FROM THE COUNTY
 74434316080000010 AND 74434316080000020 WILL MERGE INTO
 74434316080000010. PRIMARY ADDRESS FOR THE PARCEL WILL
 BE 1921 N TAMARIND AVE, THE FOLLOWING ADDRESSES HAVE
 ALSO BEEN APPROVED 1921 N TAMARIND AVE 200 201 300 301
 1923 N TAMARIND AVE AND 1931 N TAMARIND AVE. APPLICANT
 INFORMED PLANS AND APPLICATIONS FORMS NEED TO BE
 UPDATED WITH THE PRIMARY ADDRESS.

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2023-06-14 Cont ID  
Sent By cpuell Date 2023-06-14 Time 12:15 Rev Time 0.00
Received By cpuell Date 2023-06-14 Time 12:15 Sent To  
Notes
2023-06-14 12:16:06UNIFIED PARCEL LETTER UPLOADED TO THIS PERMIT IS NOT
 FOR THE PARCELS IN QUESTION FOR THIS PERMIT. THE
 PROPOSED PROJECT ENCOMPASSES TWO PARCELS
 74434316080000010 AND 74434316080000020, A UNITY OF
 TITLE WILL BE REQUIRED, YOU WILL NEED TO CONTACT VINCE
 NOEL [email protected] OR CALL 561-494-1040 TO START THE
 UNITY OF TITLE PROCEDURE. CURRENTLY THERE ARE TWO
 SEPARATE PROPERTY CONTROL NUMBER (PCN), YOU WILL NEED
 TO GO FILL OUT PALM BEACH COUNTY???S PARCEL COMBINATION
 REQUEST FORM WHICH CAN BE FOUND AT THIS LINK
 HTTPS://WWW.PBCGOV.ORG/PAPA/DEPARTMENTS/GIS.HTM, THEY
 WILL ISSUE YOU WITH A UNIFIED PARCEL CONTROL NUMBER
 (PCN). WHEN YOU CONTACT THE PROPERTY APPRAISERS YOU
 NEED TO REQUEST PRELIMINARY LETTER OF THE UNIFIED PCN.
 ONCE YOU HAVE RECEIVED THE PRELIMINARY LETTER PLEASE
 CONTACT [email protected] OR CALL 561-805-6659.
 EACH INDIVIDUAL UNIT WILL REQUIRE IT'S OWN ADDRESS
 PLEASE REACH OUT TO [email protected] OR CALL
 561-805-6659.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-05-02 Cont ID  
Sent By cpuell Date 2023-05-02 Time 13:09 Rev Time 0.00
Received By cpuell Date 2023-05-02 Time 13:09 Sent To  
Notes
2023-05-02 13:09:35NOBODY HAS CONTACTED ADDRESSING TO ADDRESS THE ADDRESS
 ISSUES. PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By cpuell Date 2022-12-16 Time 10:35 Rev Time 0.00
Received By cpuell Date 2022-12-16 Time 10:35 Sent To  
Notes
2022-12-16 10:40:29THE PROPOSED PROJECT ENCOMPASSES TWO PARCELS
 74434316080000010 AND 74434316080000020, A UNITY OF
 TITLE WILL BE REQUIRED, YOU WILL NEED TO CONTACT VINCE
 NOEL [email protected] OR CALL 561-494-1040 TO START THE
 UNITY OF TITLE PROCEDURE. CURRENTLY THERE ARE TWO
 SEPARATE PROPERTY CONTROL NUMBER (PCN), YOU WILL NEED
 TO GO FILL OUT PALM BEACH COUNTY???S PARCEL COMBINATION
 REQUEST FORM WHICH CAN BE FOUND AT THIS LINK
 HTTPS://WWW.PBCGOV.ORG/PAPA/DEPARTMENTS/GIS.HTM, THEY
 WILL ISSUE YOU WITH A UNIFIED PARCEL CONTROL NUMBER
 (PCN). WHEN YOU CONTACT THE PROPERTY APPRAISERS YOU
 NEED TO REQUEST PRELIMINARY LETTER OF THE UNIFIED PCN.
 ONCE YOU HAVE RECEIVED THE PRELIMINARY LETTER PLEASE
 CONTACT [email protected] OR CALL 561-805-6659.
 EACH INDIVIDUAL UNIT WILL REQUIRE IT'S OWN ADDRESS
 PLEASE REACH OUT TO [email protected] OR CALL
 561-805-6659.

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status N Date 2023-05-19 Cont ID  
Sent By swelter Date 2023-05-19 Time 13:39 Rev Time 0.00
Received By swelter Date 2023-05-19 Time 13:43 Sent To  
Notes
2023-05-19 13:43:11CONFIRMATION OF EXEMPTION:
 PLEASE ACCEPT THIS EMAIL AS CONFIRMATION THAT THE
 COLEMAN PARK RENAISSANCE PROJECT IS AN AFFORDABLE
 HOUSING DEVELOPMENT THAT IS BEING PARTIALLY FUNDED BY
 THE CITY THROUGH THE STATE HOUSING INITIATIVES PROGRAM
 (SHIP).
  
 KIMBERLY SPENCE
 HCD PROGRAMS MANAGER
 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
  

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By swelter Date 2023-05-17 Time 15:57 Rev Time 0.00
Received By swelter Date 2023-05-17 Time 15:59 Sent To  
Notes
2023-05-17 15:59:26DEVELOPMENT SUBJECT TO PUBLIC ART REQUIREMENT UNLESS
 THIS DEVELOPMENT HAS 51% AND ABOVE AFFORDABLE HOUSING.
 IF THE LATTER, PLEASE PROVIDE A LETTER VERIFYING THE
 DEVELOPMENT AS AFFORDABLE HOUSING AS DEFINED BY THE
 U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT.
 PLEASE CONTACT SYBILLE WELTER AT [email protected] TO
 REVIEW THE REQUIREMENTS AND OPTIONS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-07-10 Cont ID  
Sent By rmcphers Date 2023-07-10 Time 13:24 Rev Time 0.00
Received By rmcphers Date 2023-07-10 Time 13:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-16 Cont ID  
Sent By rmcphers Date 2023-06-16 Time 10:03 Rev Time 0.00
Received By rmcphers Date 2023-06-16 Time 10:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-05-08 Cont ID  
Sent By rmcphers Date 2023-05-08 Time 13:42 Rev Time 0.00
Received By rmcphers Date 2023-05-08 Time 13:39 Sent To  
Notes
2023-05-08 13:42:08NEW APT BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND
 ROOFING SYSTEMS. ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD FBC WPB 107.3.4
  
 2) PLEASE SHOW THE FINISH FLOORING TYPE. FOR THE UNITS
 ABOVE THE GROUND FLOOR THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 3) SEPARATE PERMITS ARE REQUIRED FOR - DUMPSTER
 ENCLOSURE, PARKING LOT, SITE LIGHTING, - PLEASE
 ACKNOWLEDGE THIS.
  
 4) FLOORING TEST REPORTS, WINDOW, DOOR AND ROOFING
 SYSTEM PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY
 LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION
 DOCUMENTS - FBC WPB 107.3.4.1
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By rmcphers Date 2022-12-16 Time 10:37 Rev Time 0.00
Received By rmcphers Date 2022-12-15 Time 11:07 Sent To  
Notes
2022-12-16 10:35:59NEW APT BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND
 ROOFING SYSTEMS. ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD FBC WPB 107.3.4
  
 2) PLEASE SHOW THE REQUIRED GUARD RAILING NEAR THE ROOF
 SCUTTLE HOLE - FBC 1015.7 ROOF ACCESS.
 GUARDS SHALL BE PROVIDED WHERE THE ROOF HATCH OPENING
 IS LOCATED WITHIN 10 FEET (3048 MM) OF A ROOF EDGE OR
 OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN
 SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE
 FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL BE
 CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21
 INCHES (533 MM) IN DIAMETER.
  
 3) PLEASE SHOW UNIT FIRE RATED DOOS TO BE SELF CLOSING
 - FBC 716.5.9
  
 4) PLEASE SHOW THE FINISH FLOORING TYPE. FOR THE UNITS
 ABOVE THE GROUND FLOOR THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 5) SEPARATE PERMITS ARE REQUIRED FOR - DUMPSTER
 ENCLOSURE, PARKING LOT, SITE LIGHTING, - PLEASE
 ACKNOWLEDGE THIS.
  
 6) FLOORING TEST REPORTS, WINDOW, DOOR AND ROOFING
 SYSTEM PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY
 LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION
 DOCUMENTS - FBC WPB 107.3.4.1
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-12 Cont ID  
Sent By jleahy Date 2023-05-12 Time 10:08 Rev Time 0.00
Received By jleahy Date 2023-05-12 Time 10:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-12-15 Cont ID  
Sent By mpeterso Date 2022-12-15 Time 13:07 Rev Time 0.00
Received By mpeterso Date 2022-12-15 Time 13:07 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2023-07-13 Cont ID  
Sent By cseifer Date 2023-07-13 Time 09:27 Rev Time 0.00
Received By cseifer Date 2023-07-13 Time 09:27 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2023-06-15 Cont ID  
Sent By lquinone Date 2023-06-15 Time 07:38 Rev Time 0.00
Received By lquinone Date 2023-06-15 Time 07:38 Sent To  
Notes
2023-06-15 07:39:02PROJECT UNDER FORMAL ENGINEERING REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2023-05-09 Cont ID  
Sent By lquinone Date 2023-05-09 Time 11:29 Rev Time 0.00
Received By lquinone Date 2023-05-09 Time 11:29 Sent To  
Notes
2023-05-09 11:31:51PROJECT UNDER FORMAL ENGINEERING REVIEW.
  
 THANKS,
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-12-14 Cont ID  
Sent By rrossano Date 2022-12-14 Time   Rev Time  
Received By rrossano Date 2022-12-14 Time   Sent To  
Notes
2022-12-14 20:42:33A FORMAL ENGINEERING SUBMITTAL IS REQUIRED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2023-07-12 Cont ID  
Sent By pleduc Date 2023-07-12 Time   Rev Time 0.00
Received By pleduc Date 2023-07-12 Time 11:02 Sent To  
Notes
2023-07-12 11:05:01FIRE COMMENTS:
  
 FIRE COMMENTS REGARDING THE 61G DOCUEMNTS DO NOT APPEAR
 TO STRICTLY MEETS THE REQUIREMENT, HOWEVER, IN AN
 EFFORT TO MOVE THIS PRORJECT
 AND PLAN REVIEW FORWARD, FIRE WILL PASS THIS REVIEW AND
 WILL REVIEW ALL APPLICABLE SHOP DRAWINGS FOR COMPLIANCE
 OF THE NFPA REQUIREMENTS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2023-06-09 Cont ID  
Sent By pleduc Date 2023-06-09 Time   Rev Time 0.00
Received By pleduc Date 2023-06-09 Time 09:29 Sent To  
Notes
2023-06-09 09:38:35AS STATED PREVIOUSLY AND AS SUBMITTED BELOW;
  
 FA & FS DOCUMENTS ARE REQUIRED BY FLORIDA STATUTE TO BE
 SUBMITTED BY THE EOR WITH THIS MASTER PERMIT. SHOP
 DRAWING ARE THEN TO BE BASED ON THESE DOCUMENTS AND
 SUBMITTED BY QUALIFIED CONTRACTORS.
  
 THE FA & FS DOCUMENTS WITH THIS MASTER ARE NOT REQUIRED
 TO BE FULL SETS OF DRAWINGS AND CALCULATIONS, BUT CAN
 BE IN WRITTEN FORM SIGNED AND SEALED BY THE EOR AS LONG
 AS THE MEET THE LISTED DESIIGN REQUIREMENTS
 OF THE FLORIDA STATUTE WHICH ARE LISTED BELOW.
  
 PLEASE CONSULT WITH A YOUR EOR OR A FLORIDA FIRE
 PROTECTION ENGINEER WHOM WILL KNOW WHAT THOSE
 REQUIREMENTS ARE.
  
 *******************************************************
 *******************************************************
 ***********
  
 PREVIOUS COMMENTS RE-PORTED:
  
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A FIRE SPRINKLER
 PROTECTION; HOWEVER, THERE IS NO INDICATION OF FIRE
 SPRINKLER DOCUMENTATION REQUIRED BY F.A.C 61G
  
 THE FIRE SPRINKLER AND FIRE ALARM DOCUMENTS IS REQUIRED
 TO BE SUBMITTED WITH THIS MASTER PERMIT. AFTER APPROVAL
 OF THIS MASTER WITH THE FS & FA DOCUMENTS, SHOP
 DRAWINGS CAN THEN BE SUBMITTED THAT WILL BE COMPLIANT
 WITH THE MASTER FS & FA DOCUMENTS.
  
 THE FS & FA DOCUMENTS ARE NOT REQUIRED TO BE FULL SET
 PLAN SUBMITTALS. THEY CAN BE WRITTEN DOCUMENTS BUT MUST
 CONTAIN THE REQUIRED INFO SETTING THE DESIGN CRITERIA
 PER THE NOTED F.A.C.
  
 FAC 61G15-32.002 DEFINES THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENT (5) AS WELL AS THE FIRE PROTECTION
 SYSTEM LAYOUT DOCUMENT (6). 61G15-32.003 OUTLINES THE
 COMMON REQUIREMENTS TO ALL FIRE PROTECTIONS ENGINEERING
 DOCUMENTS WITH 32.004 (2) (A-J) OUTLINING THE MINIMUM
 INFORMATION TO BE PROVIDED ON FIRE PROTECTION
 ENGINEERING DOCUMENTS FOR WATER BASED SYSTEMS. AS
 STATED IN THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP
 THE LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA
 PROVIDED IN THE FIRE PROTECTION ENGINEERING DOCUMENTS
 BY THE ENGINEER OF RECORD FOR THE FIRE SPRINKLER
 SYSTEM. THE FIRE PROTECTION SYSTEM ENGINEERING
 DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING
 PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED
 FOR THE FIRE SPRINKLER INSTALLATION PERMIT.
  
 PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004,
 FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF
 APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING
 DOCUMENTS.
 (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF
 PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR
 INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING
 PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER???S
 RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31,
 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE AHJ. THE DOCUMENTS SHALL INCLUDE:
 (A) INFORMATION THAT PROVIDES MATERIAL SPECIFICATIONS
 REQUIRED FOR THE SAFE OPERATION OF THE SYSTEM THAT IS A
 RESULT OF ENGINEERING CALCULATIONS, KNOWLEDGE AND
 EXPERIENCE.
 (B) LIST FEDERAL, STATE, MUNICIPAL, AND COUNTY
 STANDARDS, CODES, ORDINANCES, LAWS, AND RULES, WITH
 THEIR EFFECTIVE DATES, THAT THE ENGINEERING DOCUMENTS
 ARE INTENDED TO CONFORM TO.
 (C) INFORMATION, AS DETERMINED BY THE ENGINEER OF
 RECORD, NEEDED FOR THE SAFE AND EFFICIENT OPERATION OF
 THE SYSTEM.
 (D) LIST ENGINEERING DESIGN CRITERIA; REFERENCE PROJECT
 SPECIFIC STUDIES, REPORTS, AND DELEGATED ENGINEERING
 DOCUMENTS.
 (E) IDENTIFY CLEARLY ELEMENTS OF THE DESIGN THAT VARY
 FROM THE GOVERNING STANDARDS AND DEPICT/IDENTIFY THE
 ALTERNATE METHOD USED TO ENSURE COMPLIANCE WITH THE
 STATED PURPOSE OF THESE RESPONSIBILITY RULES.
 (2) ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND
 BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING
 DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR
 CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE
 OF SUCH DOCUMENTS.
 (3) WHEN ELEMENTS OF THE PROJECT ARE SHOWN ON AN
 ENGINEERING DOCUMENT ONLY FOR INFORMATION OR
 CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO
 ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER
 SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS
 RESPONSIBILITY.
 (4) ENGINEERING DRAWINGS SHALL BE LEGIBLE AND CLEARLY
 DEFINE AND DELINEATE THE WORK IN THE PROJECT. THEY MUST
 ALSO COMPLY WITH CHAPTER 61G15-23, F.A.C., SEALS.
 (5) ENGINEERS SHALL CLEARLY NOTE ON ANY PRELIMINARY
 ENGINEERING DOCUMENTS THAT SUCH DOCUMENTS ARE NOT IN
 FINAL FORM, BUT ARE BEING TRANSMITTED TO THE PUBLIC
 AGENCY TO RECEIVE AGENCY REVIEWS, COMMENTS AND
 INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE
 REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES
 WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE
 AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A
 PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR
 AGENCY APPROVAL ACTION ON THE SAME PROJECT.
  
  
 EVEN IF THE EOR DEFERS TO A LOCAL QUALIFIED CONTRACTOR,
 THAT CONTRACTOR MUST SUBMIT THE REQUIRED 61G
 INFORMATION WITH THIS MASTER.
  
 61G15-32.008 DESIGN OF FIRE ALARMS AND DETECTION
 SYSTEMS.
 (1) FIRE ALARMS AND DETECTION SYSTEMS INCLUDE FIRE
 PROTECTION SUPERVISION, EMERGENCY ALARM CIRCUITS,
 ACTIVATION OF LIFE SAFETY SYSTEM CONTROLS AND REMOTE
 SIGNALING OF EMERGENCY CONDITIONS.
 (2) THE DESIGN SPECIFICATIONS SHALL BE BASED ON THE
 FLORIDA BUILDING CODE (2007), THE FLORIDA FIRE
 PREVENTION CODE, OR AS REQUIRED BY THE LOCAL AUTHORITY
 HAVING JURISDICTION.
 (3) FOR FIRE ALARM PLANS ON SMALL SYSTEMS BELOW THE
 THRESHOLD REQUIREMENTS FOR MANDATORY USE OF
 PROFESSIONAL ENGINEERING SERVICES, THE ENGINEER OF
 RECORD SHALL SPECIFY THE MINIMUM SYSTEM REQUIREMENTS.
 (4) TO ENSURE MINIMUM DESIGN QUALITY OF FIRE ALARM AND
 DETECTION SYSTEMS ENGINEERING DOCUMENTS, SAID DOCUMENTS
 SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION
 WHEN APPLICABLE:
 (A) THE PLANS SHALL BE CLEAR, WITH A SYMBOLS LEGEND,
 SYSTEM RISER DIAGRAM SHOWING ALL INITIATION AND
 NOTIFICATION COMPONENTS, AND CABLING REQUIREMENTS.
 INDICATE LOCATIONS WHERE FIRE RATINGS ARE REQUIRED AS
 DETERMINED BY THE SYSTEM???S SURVIVABILITY
 REQUIREMENTS. IDENTIFY THE GENERAL OCCUPANCY OF THE
 PROTECTED PROPERTY, AND FOR EACH ROOM AND AREA UNLESS
 IT IS CLEAR FROM FEATURES SHOWN.
 (B) LOCATE INITIATION AND NOTIFICATION DEVICES AND
 CONNECTIONS TO RELATED SYSTEMS ON THE FLOOR PLANS AND
 SECTIONS WHEN NEEDED FOR CLARITY. RELATED SYSTEMS
 INCLUDE ELEVATOR CONTROLS SMOKE CONTROL SYSTEMS,
 DAMPERS, AND DOORS.
 (C) STROBE INTENSITY AND SPEAKER OUTPUT RATINGS FOR ALL
 NOTIFICATION DEVICES.
 (D) IDENTIFY THE CLASS AND STYLE OF CIRCUITS AS LISTED
 IN THE NFPA 72.
 (E) IDENTIFY THE FUNCTIONS REQUIRED BY THE ALARM AND
 CONTROL SYSTEMS INCLUDING THE TRANSMISSION OF EMERGENCY
 SIGNALS BEING MONITORED OR ANNUNCIATED.
 (F) INDICATE WHETHER THE FIRE ALARM IS CONVENTIONAL OR
 ADDRESSABLE, AND INDICATE ALL ZONING.
 (G) LOCATE SURGE PROTECTIVE DEVICES AND REQUIRED
 PROTECTIVE FEATURES.
 (H) LOCATE SYSTEM DEVICES THAT ARE SUBJECT TO
 ENVIRONMENTAL FACTORS, AND INDICATE REQUIREMENTS FOR
 THE PROTECTION OF EQUIPMENT FROM TEMPERATURE, HUMIDITY
 OR CORROSIVE ATMOSPHERES, INCLUDING COASTAL SALT AIR.
 (I) THE PLANS SHALL INCLUDE A SITE PLAN OF THE
 IMMEDIATE AREA AROUND THE PROTECTED BUILDING, STRUCTURE
 OR EQUIPMENT WHEN ALARM DEVICES ARE REQUIRED OUTSIDE
 THE STRUCTURE.
 (J) IN BUILDINGS WERE SMOKE DETECTION WILL BE
 OBSTRUCTED BY WALLS, BEAMS OR CEILING FEATURES, THE
 ENGINEER OF RECORD SHALL PROVIDE APPLICABLE DESIGN AND
 DETAILS TO DIRECT THE INSTALLER TO MITIGATE THE
 OBSTRUCTIONS. IN BUILDINGS WITH SMOKE DETECTION UNDER A
 PITCHED ROOF, THE PLANS SHALL INDICATE THE ROOF PITCH
 AND A BUILDING SECTION SHALL BE PROVIDED AS PART OF THE
 ENGINEERING DESIGN DOCUMENTS.
 (K) FIRE DETECTION SYSTEMS UTILIZING SMOKE DETECTION IN
 SITUATIONS WHERE SMOKE STRATIFICATION IS ANTICIPATED,
 THE DESIGN SHALL PROVIDE THE NECESSARY CRITERIA TO
 MITIGATE THE DETECTION PROBLEMS.
 (L) SYSTEMS DESIGNED USING PERFORMANCE BASED CRITERIA
 SHALL BE IDENTIFIED AND REFERENCED TO DESIGN GUIDES OR
 STANDARDS APPROVED BY THE LOCAL AUTHORITY HAVING
 JURISDICTION CONSISTENT WITH STANDARDS ADOPTED BY THE
 FLORIDA FIRE PREVENTION CODE AND THE FLORIDA BUILDING
 CODE (2007).
 (M) THE SYSTEM DESIGN MUST INDICATE IF THE SYSTEM IS TO
 PROVIDE A GENERAL EVACUATION SIGNAL OR A ZONED
 EVACUATION FOR ALL HIGH-RISE BUILDINGS OR
 MULTI-TENANTED PROPERTIES AS DEFINED IN THE FLORIDA
 BUILDING CODE (2007).
 (N) WIRING REQUIREMENTS FOR UNDERGROUND, WET LOCATIONS,
 CAMPUS STYLE WIRING, PROTECTION AGAINST DAMAGE AND
 BURIAL DEPTH SHALL BE SPECIFIED OR INDICATED ON THE
 ENGINEERING DESIGN DOCUMENTS.
 (O) REQUIREMENTS FOR OPERATIONS AND MAINTENANCE
 PROCEDURES, MANUALS, SYSTEM DOCUMENTATION, AND
 INSTRUCTION OF OWNER???S OPERATING PERSONNEL, AS NEEDED
 TO OPERATE THE SYSTEMS AS INTENDED OVER TIME.
 (5) IN THE EVENT THAT THE ENGINEER OF RECORD ELECTS TO
 SPECIFY SPECIFIC EQUIPMENT AND TO SHOW THE REQUIRED
 WIRING, BATTERY AND VOLTAGE DROP (CIRCUIT ANALYSIS)
 CALCULATIONS SHALL BE COMPLETED. THE CALCULATIONS SHALL
 BE COMPLETED USING THE EQUIPMENT MANUFACTURE???S DATA
 AND APPLICABLE NFPA 72 PROCEDURES.
 (6) SYSTEM TEST REQUIREMENTS SHALL BE NOTED ON THE
 ENGINEERING DESIGN DOCUMENTS.
 (7) WHEN THE ENGINEER DETERMINES THAT SPECIAL
 REQUIREMENTS ARE REQUIRED BY THE OWNER, INSURANCE
 UNDERWRITER OR LOCAL FIRE CODE AMENDMENTS THESE
 REQUIREMENTS SHALL BE DOCUMENTED OR REFERENCED ON THE
 ENGINEERING DESIGN DOCUMENTS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2023-05-04 Cont ID  
Sent By pleduc Date 2023-05-04 Time   Rev Time 0.00
Received By pleduc Date 2023-05-04 Time 10:46 Sent To  
Notes
2023-05-04 10:56:20THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A FIRE SPRINKLER
 PROTECTION; HOWEVER, THERE IS NO INDICATION OF FIRE
 SPRINKLER DOCUMENTATION REQUIRED BY F.A.C 61G
  
 THE FIRE SPRINKLER AND FIRE ALARM DOCUMENTS IS REQUIRED
 TO BE SUBMITTED WITH THIS MASTER PERMIT. AFTER APPROVAL
 OF THIS MASTER WITH THE FS & FA DOCUMENTS, SHOP
 DRAWINGS CAN THEN BE SUBMITTED THAT WILL BE COMPLIANT
 WITH THE MASTER FS & FA DOCUMENTS.
  
 THE FS & FA DOCUMENTS ARE NOT REQUIRED TO BE FULL SET
 PLAN SUBMITTALS. THEY CAN BE WRITTEN DOCUMENTS BUT MUST
 CONTAIN THE REQUIRED INFO SETTING THE DESIGN CRITERIA
 PER THE NOTED F.A.C.
  
 FAC 61G15-32.002 DEFINES THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENT (5) AS WELL AS THE FIRE PROTECTION
 SYSTEM LAYOUT DOCUMENT (6). 61G15-32.003 OUTLINES THE
 COMMON REQUIREMENTS TO ALL FIRE PROTECTIONS ENGINEERING
 DOCUMENTS WITH 32.004 (2) (A-J) OUTLINING THE MINIMUM
 INFORMATION TO BE PROVIDED ON FIRE PROTECTION
 ENGINEERING DOCUMENTS FOR WATER BASED SYSTEMS. AS
 STATED IN THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP
 THE LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA
 PROVIDED IN THE FIRE PROTECTION ENGINEERING DOCUMENTS
 BY THE ENGINEER OF RECORD FOR THE FIRE SPRINKLER
 SYSTEM. THE FIRE PROTECTION SYSTEM ENGINEERING
 DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING
 PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED
 FOR THE FIRE SPRINKLER INSTALLATION PERMIT.
  
 PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004,
 FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF
 APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING
 DOCUMENTS.
 (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF
 PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR
 INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING
 PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER???S
 RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31,
 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE AHJ. THE DOCUMENTS SHALL INCLUDE:
 (A) INFORMATION THAT PROVIDES MATERIAL SPECIFICATIONS
 REQUIRED FOR THE SAFE OPERATION OF THE SYSTEM THAT IS A
 RESULT OF ENGINEERING CALCULATIONS, KNOWLEDGE AND
 EXPERIENCE.
 (B) LIST FEDERAL, STATE, MUNICIPAL, AND COUNTY
 STANDARDS, CODES, ORDINANCES, LAWS, AND RULES, WITH
 THEIR EFFECTIVE DATES, THAT THE ENGINEERING DOCUMENTS
 ARE INTENDED TO CONFORM TO.
 (C) INFORMATION, AS DETERMINED BY THE ENGINEER OF
 RECORD, NEEDED FOR THE SAFE AND EFFICIENT OPERATION OF
 THE SYSTEM.
 (D) LIST ENGINEERING DESIGN CRITERIA; REFERENCE PROJECT
 SPECIFIC STUDIES, REPORTS, AND DELEGATED ENGINEERING
 DOCUMENTS.
 (E) IDENTIFY CLEARLY ELEMENTS OF THE DESIGN THAT VARY
 FROM THE GOVERNING STANDARDS AND DEPICT/IDENTIFY THE
 ALTERNATE METHOD USED TO ENSURE COMPLIANCE WITH THE
 STATED PURPOSE OF THESE RESPONSIBILITY RULES.
 (2) ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND
 BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING
 DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR
 CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE
 OF SUCH DOCUMENTS.
 (3) WHEN ELEMENTS OF THE PROJECT ARE SHOWN ON AN
 ENGINEERING DOCUMENT ONLY FOR INFORMATION OR
 CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO
 ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER
 SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS
 RESPONSIBILITY.
 (4) ENGINEERING DRAWINGS SHALL BE LEGIBLE AND CLEARLY
 DEFINE AND DELINEATE THE WORK IN THE PROJECT. THEY MUST
 ALSO COMPLY WITH CHAPTER 61G15-23, F.A.C., SEALS.
 (5) ENGINEERS SHALL CLEARLY NOTE ON ANY PRELIMINARY
 ENGINEERING DOCUMENTS THAT SUCH DOCUMENTS ARE NOT IN
 FINAL FORM, BUT ARE BEING TRANSMITTED TO THE PUBLIC
 AGENCY TO RECEIVE AGENCY REVIEWS, COMMENTS AND
 INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE
 REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES
 WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE
 AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A
 PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR
 AGENCY APPROVAL ACTION ON THE SAME PROJECT.
  
  
 EVEN IF THE EOR DEFERS TO A LOCAL QUALIFIED CONTRACTOR,
 THAT CONTRACTOR MUST SUBMIT THE REQUIRED 61G
 INFORMATION WITH THIS MASTER.
  
 61G15-32.008 DESIGN OF FIRE ALARMS AND DETECTION
 SYSTEMS.
 (1) FIRE ALARMS AND DETECTION SYSTEMS INCLUDE FIRE
 PROTECTION SUPERVISION, EMERGENCY ALARM CIRCUITS,
 ACTIVATION OF LIFE SAFETY SYSTEM CONTROLS AND REMOTE
 SIGNALING OF EMERGENCY CONDITIONS.
 (2) THE DESIGN SPECIFICATIONS SHALL BE BASED ON THE
 FLORIDA BUILDING CODE (2007), THE FLORIDA FIRE
 PREVENTION CODE, OR AS REQUIRED BY THE LOCAL AUTHORITY
 HAVING JURISDICTION.
 (3) FOR FIRE ALARM PLANS ON SMALL SYSTEMS BELOW THE
 THRESHOLD REQUIREMENTS FOR MANDATORY USE OF
 PROFESSIONAL ENGINEERING SERVICES, THE ENGINEER OF
 RECORD SHALL SPECIFY THE MINIMUM SYSTEM REQUIREMENTS.
 (4) TO ENSURE MINIMUM DESIGN QUALITY OF FIRE ALARM AND
 DETECTION SYSTEMS ENGINEERING DOCUMENTS, SAID DOCUMENTS
 SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION
 WHEN APPLICABLE:
 (A) THE PLANS SHALL BE CLEAR, WITH A SYMBOLS LEGEND,
 SYSTEM RISER DIAGRAM SHOWING ALL INITIATION AND
 NOTIFICATION COMPONENTS, AND CABLING REQUIREMENTS.
 INDICATE LOCATIONS WHERE FIRE RATINGS ARE REQUIRED AS
 DETERMINED BY THE SYSTEM???S SURVIVABILITY
 REQUIREMENTS. IDENTIFY THE GENERAL OCCUPANCY OF THE
 PROTECTED PROPERTY, AND FOR EACH ROOM AND AREA UNLESS
 IT IS CLEAR FROM FEATURES SHOWN.
 (B) LOCATE INITIATION AND NOTIFICATION DEVICES AND
 CONNECTIONS TO RELATED SYSTEMS ON THE FLOOR PLANS AND
 SECTIONS WHEN NEEDED FOR CLARITY. RELATED SYSTEMS
 INCLUDE ELEVATOR CONTROLS SMOKE CONTROL SYSTEMS,
 DAMPERS, AND DOORS.
 (C) STROBE INTENSITY AND SPEAKER OUTPUT RATINGS FOR ALL
 NOTIFICATION DEVICES.
 (D) IDENTIFY THE CLASS AND STYLE OF CIRCUITS AS LISTED
 IN THE NFPA 72.
 (E) IDENTIFY THE FUNCTIONS REQUIRED BY THE ALARM AND
 CONTROL SYSTEMS INCLUDING THE TRANSMISSION OF EMERGENCY
 SIGNALS BEING MONITORED OR ANNUNCIATED.
 (F) INDICATE WHETHER THE FIRE ALARM IS CONVENTIONAL OR
 ADDRESSABLE, AND INDICATE ALL ZONING.
 (G) LOCATE SURGE PROTECTIVE DEVICES AND REQUIRED
 PROTECTIVE FEATURES.
 (H) LOCATE SYSTEM DEVICES THAT ARE SUBJECT TO
 ENVIRONMENTAL FACTORS, AND INDICATE REQUIREMENTS FOR
 THE PROTECTION OF EQUIPMENT FROM TEMPERATURE, HUMIDITY
 OR CORROSIVE ATMOSPHERES, INCLUDING COASTAL SALT AIR.
 (I) THE PLANS SHALL INCLUDE A SITE PLAN OF THE
 IMMEDIATE AREA AROUND THE PROTECTED BUILDING, STRUCTURE
 OR EQUIPMENT WHEN ALARM DEVICES ARE REQUIRED OUTSIDE
 THE STRUCTURE.
 (J) IN BUILDINGS WERE SMOKE DETECTION WILL BE
 OBSTRUCTED BY WALLS, BEAMS OR CEILING FEATURES, THE
 ENGINEER OF RECORD SHALL PROVIDE APPLICABLE DESIGN AND
 DETAILS TO DIRECT THE INSTALLER TO MITIGATE THE
 OBSTRUCTIONS. IN BUILDINGS WITH SMOKE DETECTION UNDER A
 PITCHED ROOF, THE PLANS SHALL INDICATE THE ROOF PITCH
 AND A BUILDING SECTION SHALL BE PROVIDED AS PART OF THE
 ENGINEERING DESIGN DOCUMENTS.
 (K) FIRE DETECTION SYSTEMS UTILIZING SMOKE DETECTION IN
 SITUATIONS WHERE SMOKE STRATIFICATION IS ANTICIPATED,
 THE DESIGN SHALL PROVIDE THE NECESSARY CRITERIA TO
 MITIGATE THE DETECTION PROBLEMS.
 (L) SYSTEMS DESIGNED USING PERFORMANCE BASED CRITERIA
 SHALL BE IDENTIFIED AND REFERENCED TO DESIGN GUIDES OR
 STANDARDS APPROVED BY THE LOCAL AUTHORITY HAVING
 JURISDICTION CONSISTENT WITH STANDARDS ADOPTED BY THE
 FLORIDA FIRE PREVENTION CODE AND THE FLORIDA BUILDING
 CODE (2007).
 (M) THE SYSTEM DESIGN MUST INDICATE IF THE SYSTEM IS TO
 PROVIDE A GENERAL EVACUATION SIGNAL OR A ZONED
 EVACUATION FOR ALL HIGH-RISE BUILDINGS OR
 MULTI-TENANTED PROPERTIES AS DEFINED IN THE FLORIDA
 BUILDING CODE (2007).
 (N) WIRING REQUIREMENTS FOR UNDERGROUND, WET LOCATIONS,
 CAMPUS STYLE WIRING, PROTECTION AGAINST DAMAGE AND
 BURIAL DEPTH SHALL BE SPECIFIED OR INDICATED ON THE
 ENGINEERING DESIGN DOCUMENTS.
 (O) REQUIREMENTS FOR OPERATIONS AND MAINTENANCE
 PROCEDURES, MANUALS, SYSTEM DOCUMENTATION, AND
 INSTRUCTION OF OWNER???S OPERATING PERSONNEL, AS NEEDED
 TO OPERATE THE SYSTEMS AS INTENDED OVER TIME.
 (5) IN THE EVENT THAT THE ENGINEER OF RECORD ELECTS TO
 SPECIFY SPECIFIC EQUIPMENT AND TO SHOW THE REQUIRED
 WIRING, BATTERY AND VOLTAGE DROP (CIRCUIT ANALYSIS)
 CALCULATIONS SHALL BE COMPLETED. THE CALCULATIONS SHALL
 BE COMPLETED USING THE EQUIPMENT MANUFACTURE???S DATA
 AND APPLICABLE NFPA 72 PROCEDURES.
 (6) SYSTEM TEST REQUIREMENTS SHALL BE NOTED ON THE
 ENGINEERING DESIGN DOCUMENTS.
 (7) WHEN THE ENGINEER DETERMINES THAT SPECIAL
 REQUIREMENTS ARE REQUIRED BY THE OWNER, INSURANCE
 UNDERWRITER OR LOCAL FIRE CODE AMENDMENTS THESE
 REQUIREMENTS SHALL BE DOCUMENTED OR REFERENCED ON THE
 ENGINEERING DESIGN DOCUMENTS.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By cwalker Date 2022-12-16 Time   Rev Time  
Received By cwalker Date 2022-12-16 Time   Sent To  
Notes
2022-12-16 09:37:56FIRE REVIEW COMMENTS:
  
 (1) FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS WERE
 NOT INCLUDED ON THE MASTER PLAN. PER FAC 61G15-32.002
 DEFINES THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENT
 (5) AS WELL AS THE FIRE PROTECTION SYSTEM LAYOUT
 DOCUMENT (6). 61G15-32.003 OUTLINES THE COMMON
 REQUIREMENTS TO ALL FIRE PROTECTIONS ENGINEERING
 DOCUMENTS WITH 32.004 (2) (A-J) OUTLINING THE MINIMUM
 INFORMATION TO BE PROVIDED ON FIRE PROTECTION
 ENGINEERING DOCUMENTS FOR WATER-BASED SYSTEMS. AS
 STATED IN THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP
 THE LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA
 PROVIDED IN THE FIRE PROTECTION ENGINEERING DOCUMENTS
 BY THE ENGINEER OF RECORD FOR THE FIRE SPRINKLER
 SYSTEM. THE FIRE PROTECTION SYSTEM ENGINEERING
 DOCUMENTS ARE SUBMITTED FOR THE MASTER PERMIT (BUILDING
 PERMIT PER FBC) AND THE LAYOUT DOCUMENTS ARE SUBMITTED
 FOR THE FIRE SPRINKLER INSTALLATION PERMIT.
  
 (2) SEPARATE PERMIT AND SHOP DRAWINGS ARE NEEDED FOR
 ANY FIRE ALARM, FIRE SPRINKLER AND UNDERGROUND
 FIRELINE.
  
 (3) PLAN SUBMITTAL DOES NOT INDICATE SMOKE ALARM
 LOCATIONS. NFPA 101, 30.3.4.5
  
 (4) GRAB BARS WERE NOT INDICATED IN THE BATHTUB/SHOWER.
 NFPA 101, 30.2.1.3
  
 (5) RESUBMITTALS MAY GENERATE ADDITIONAL COMMENTS OR
 QUESTIONS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-07-14 Cont ID  
Sent By aoliver Date 2023-07-14 Time 08:21 Rev Time 0.00
Received By aoliver Date 2023-07-07 Time 16:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-16 Cont ID  
Sent By rmcphers Date 2023-06-16 Time 10:17 Rev Time 0.00
Received By rmcphers Date 2023-06-08 Time 09:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-17 Cont ID  
Sent By lmarchan Date 2023-05-17 Time 16:53 Rev Time 0.00
Received By lmarchan Date 2023-05-02 Time 08:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-06 Cont ID  
Sent By lmarchan Date 2023-02-06 Time 08:29 Rev Time 0.00
Received By lmarchan Date 2022-11-03 Time 14:57 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2023-07-13 Time 15:50 Sent To  
Notes
2023-07-13 15:50:307/13/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By rmcphers Date 2022-12-16 Time 10:37 Rev Time 0.00
Received By rmcphers Date 2022-12-16 Time 10:37 Sent To  
Notes
2022-12-16 10:37:47PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By medwards Date 2023-05-09 Time 07:29 Rev Time 0.00
Received By medwards Date 2023-05-09 Time 07:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-12-15 Cont ID  
Sent By medwards Date 2022-12-15 Time 09:56 Rev Time 0.00
Received By medwards Date 2022-12-15 Time 08:47 Sent To  
Notes
2022-12-15 09:56:361ST REVIEW FMC
 PERMIT: 22100754
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-1: THERE ARE 2 FLOORS ON THIS DRAWING, THEY
 WILL NEED TO BE LABELED OR IDENTIFIED. THE THIRD FLOOR
 SHOULD ALSO BE IDENTIFIED ON SHEET M-2. FBC 107.3.5
  
 2) PLEASE SHOW THAT THE CONDENSING UNITS ARE A MINIMUM
 OF 10 FEET FROM THE ROOFS EDGE OR PROVIDE THE REQUIRED
 GUARDS. FMC 304.11
  
 3) THE FULLY SEALED DOORS SHOWN ON SHEET M-1 AND M-2
 NEED TO BE SHOWN ON THE DOOR SCHEDULE ON SHEET A-08.
 FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2023-07-12 Cont ID  
Sent By ccole Date 2023-07-12 Time 15:37 Rev Time 0.00
Received By ccole Date 2023-07-12 Time 15:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2023-06-12 Cont ID  
Sent By ccole Date 2023-06-12 Time 15:20 Rev Time 0.00
Received By ccole Date 2023-06-12 Time 15:00 Sent To  
Notes
2023-06-12 15:22:343RD REVIEW FBC-2020 PLUMBING
 PERMIT- 22100754
 6/12/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FHDA- FAIR HOUSING DESIGN ACT MANUAL
  
 PLAN REVIEW RESULTS: DENIED. 3RD REQUEST FOR THE
 POTABLE WATER BACKFLOW PERMIT APPLICATION TO BE
 SUBMITTED. IF YOU DON'T UNDERSTAND WHAT IS REQUIRED
 PLEASE CONTACT ME.
  
 1) AS PREVIOUSLY REQUESTED, PLEASE SUBMIT THE PERMIT
 APPLICATION FOR THE POTABLE WATER BACKFLOW PREVENTER-
 THE SUBMITTED PLUMBING PLANS FOR THE BUILDING WILL NOT
 BE APPROVED UNTIL A PERMIT APPLICATION FOR THE POTABLE
 WATER BACKFLOW PREVENTER HAS BEEN SUBMITTED. YOU CAN
 SUBMIT AN APPLICATION TBD (TO BE DETERMINED) IF YOU DO
 NOT HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND
 I WILL CHANGE THE REVIEW STATUS TO PASS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-05-04 Cont ID  
Sent By ccole Date 2023-05-04 Time 15:14 Rev Time 0.00
Received By ccole Date 2023-05-04 Time 14:46 Sent To  
Notes
2023-05-04 15:27:483RD REVIEW FBC-2020 PLUMBING
 PERMIT- 22100754
 5/4/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FHDA- FAIR HOUSING DESIGN ACT MANUAL
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) AS PREVIOUSLY REQUESTED, PLEASE SUBMIT THE PERMIT
 APPLICATION FOR THE POTABLE WATER BACKFLOW PREVENTER-
 THE SUBMITTED PLUMBING PLANS FOR THE BUILDING WILL NOT
 BE APPROVED UNTIL A PERMIT APPLICATION FOR THE POTABLE
 WATER BACKFLOW PREVENTER HAS BEEN SUBMITTED. YOU CAN
 SUBMIT AN APPLICATION TBD (TO BE DETERMINED) IF YOU DO
 NOT HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND
 I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 2) SHEET A10.1: CORRECT CLEAR FLOOR SPACES IN DETAIL 2
 TO SHOW A FORWARD APPROACH TO THE LAVATORY EXTENDING
 UNDER THE UNIT, AND A PARALLEL APPROACH TO THE BATHTUB
 IN ACCORDANCE WITH SECS. 606.2 AND 607.2 FBC.
  
 3) A10.1: PLEASE DETAIL THE REQUIRED GRAB BAR AT THE
 BATHTUB HEAD END WALL- SEC. 607.4.2.3 FBC ACC.
  
 4) P-3 & P-4: THE PVC WATER HEATER DRAIN LINES IN THE
 AC CLOSET PLENUM ENCLOSURES ARE NOT PERMITTED PER SEC
 602.2.1 FBC M. PVC IS COMBUSTIBLE MATERIAL AND CAN BE
 USED OUTSIDE OF THE ENCLOSURES. PLEASE SELECT A DRAIN
 MATERIAL THAT MEETS COMPLIANCE SUCH AS COPPER.
  
 5) P-5: PLEASE CORRECT THE NOTE FROM THE FBC RES. CODE
 INDICATING NON-RECIRCULATED HOT WATER SHALL NOT EXCEED
 100 FT. REFER TO SEC. 607.2 FBC P- THE LONGEST
 ALLOWANBLE DISTANCE IS 50 FT.
  
 6) P-6: A NEW WATER HEATER NOTE INDICATES A TEMPERATURE
 LIMITING DEVICE SHALL BE PROVIDED HOWEVER NO DEVICE IS
 SHOWN. PLEASE SHOW THE LOCATION OF THE DEVICE AND
 PIPING CONNECTIONS- SEC. 607.1.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-12-21 Cont ID  
Sent By ccole Date 2022-12-21 Time 16:51 Rev Time 0.00
Received By ccole Date 2022-12-15 Time 11:08 Sent To  
Notes
2022-12-21 16:53:421ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22100754
 12/16/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FHDA- FAIR HOUSING DESIGN ACT MANUAL
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING
 ITEMS SHOWN ON THE PLANS:
 * POTABLE WATER SERVICE BACKFLOW PREVENTER.
 * FIRE LINE BACKFLOW PREVENTER.
 * IRRIGATION SYSTEM
 * IRRIGATION BACKFLOW PREVENTER
 THE SUBMITTED PLUMBING PLANS FOR THE BUILDING WILL NOT
 BE APPROVED UNTIL A PERMIT APPLICATION FOR THE POTABLE
 WATER BACKFLOW PREVENTER HAS BEEN SUBMITTED. YOU CAN
 SUBMIT AN APPLICATION TBD (TO BE DETERMINED) IF YOU DO
 NOT HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND
 I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 2) SHEET A-1.0: PLEASE REFER TO SEC. 233 FBC
 ACCESSIBILITY. BASED ON SECS. 233.3.1 & 233.3.1.1 A
 MINIMUM OF ONE OF THE SIX DWELLING UNITS SHALL BE
 DESIGNED WITH COMMUNICATION AND MOBILITY FEATURES IN
 COMPLIANCE WITH SECS. 809.2 & 809.4.
  
 PLEASE NOTE THE EXCEPTION UNDER 233.3.1 WHICH COULD BE
 APPLICABLE TO THE ENTIRE NEIGHBORHOOD RENAISSANCE
 PROJECT AS A WHOLE:
 EXCEPTION: WHERE FACILITIES CONTAIN 15 OR FEWER
 RESIDENTIAL DWELLING UNITS, THE REQUIREMENTS OF
 233.3.1.1 AND 233.3.1.2 SHALL APPLY TO THE TOTAL NUMBER
 OF RESIDENTIAL DWELLING UNITS THAT ARE CONSTRUCTED
 UNDER A SINGLE CONTRACT, OR ARE DEVELOPED AS A WHOLE,
 WHETHER OR NOT LOCATED ON A COMMON SITE.
  
 CONCERNING THE PLUMBING REVIEW, THE BATHROOM IN THE
 UNIT THAT MUST MEET COMPLIANCE SHALL BE DESIGNED IN
 ACCORDANCE WITH 809.4. SEC. 809.4 REFERS THE DESIGNER
 TO SECS. 603-610 FOR TOILET AND BATHING FIXTURE
 INSTALLATIONS. BECAUSE 809.2 REQUIRES THE SELECTED UNIT
 TO BE ON AN ACCESSIBLE ROUTE IT APPEARS THE UNIT
 MEETING COMPLIANCE SHALL BE ON THE GROUND FLOOR. PLEASE
 PROVIDE AN ENLARGED DRAWING OF THE SELECTED UNIT
 INDICATING COMPLIANCE WITH THE FOLLOWING LIST OF FBC
 ACC COMPLIANCES:
  
 A) SEC. 603.2.1: PROVIDE A TURNING SPACE IN THE
 BATHROOM COMPLYING WITH SEC. 304.
  
 B) SEC. 603.3 SHOW THE HEIGHT OF THE MIRROR AT THE
 LAVATORY TO BE INSTALLED WITH THE REFLECTIVE SURFACE 40
 INCHES MAXIMUM FOR THE FINISHED FLOOR.
  
 C) SEC. 604.3: CLEARANCE AROUND THE WATER CLOSET SHALL
 BE 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE
 SIDE WALL AND 56 INCHES MINIMUM MEASURE PERPENDICULAR
 FOR THE REAR WALL. PROVIDE A 60 IN. WIDE X 56 IN. CLEAR
 FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE WATER
 CLOSETS. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE
 LOCATED WITHIN THE REQUIRED CLEARANCE, HOWEVER THERE IS
 AN EXCEPTION WHICH ALLOWS A LAVATORY TO BE INSTALLED ON
 THE REAR WALL 18 INCHES MINIMUM FROM THE WATER CLOSER
 CENTERLINE WHERE THE CLEARANCE AT THE WATER CLOSET IS
 66 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL.
  
 D) SEC. 606.2: A 30 INCHES X 48 INCHES CLEAR FLOOR
 SPACE POSITIONED FOR A FORWARD APPROACH IS REQUIRED FOR
 THE LAVATORY. KNEE AND TOE CLEARANCES ARE REQUIRED
 HOWEVER PLEASE NOTE EXCEPTION 3 A, B, & C WHICH ALLOWS
 FOR REMOVABLE CABINETRY AT THE LAVATORY.
  
 E) SEC. 604.2: SHOW THE CENTERLINE OF THE WATER CLOSET
 TO BE 16 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM THE
 SIDE WALL.
  
 F) SEC. 604.4 EXCEPTION 2: SHOW THE HEIGHT OF THE WATER
 CLOSET 15 INCHES MINIMUM AND19 IINCHES MAXIMUM FROM THE
 FINISHED FLOOR.
  
 G) SEC. 604.5 EXCEPTION 2: SHOW LOCATIONS, LENGTHS, AND
 MOUNTING HEIGHTS OF GRAB BARS FOR THE WATER CLOSETS-
 SECS. 604.5 & 609.4, FIGURES 604.5.1 & 604.5.2, OR
 PROVIDE REINFORCEMENT LOCATIONS FOR FUTURE
 INSTALLATIONS PER EXCEPTION 2.
  
 H) SEC. 604.7: SHOW THE CENTERLINE OF THE TOILET PAPER
 DISPENSER TO BE LOCATED 7 INCHES MINIMUM TO 9 INCHES
 MAXIMUM FROM THE FRONT OF THE WATER CLOSET TO THE
 CENTERLINE OF THE DISPENSER.
  
 I) SEC. 606.3: SHOW THE HEIGHT OF THE LAVATORY SINK RIM
 OR COUNTER SURFACE TO BE MAXIMUM 34 INCHES FROM THE
 FINISHED FLOOR UNLESS MEETING EXCEPTION 2 WHICH ALLOWS
 THE HEIGHT TO BE 29-36 INCHES WHERE THE PLUMBING ROUGH
 IN LOCATIONS ALLOW FOR A SINK AT A HEIGHT OF 29 INCHES.
  
 J) SEC. 607.2: SHOW THE CLEAR FLOOR SPACE FOR THE
 BATHTUB TO EXTEND THE LENGTH OF THE BATHTUB AND 30
 INCHES WIDE MINIMUM. A LAVATORY COMPLYING WITH SEC. 606
 IS PERMITTED AT THE CONTROL END OF THE CLEARANCE.
  
 K) SEC. 607.3: SHOW EITHER A PERMANENT SEAT AT THE HEAD
 OF THE TUB OR A REMOVABLE SEAT SHALL BE PROVIDED.
 PLEASE SEE SECS. 607.4.1- 607.4.2.3.
  
 L) SEC. 607.4: SHOW GRAB LOCATIONS IN COMPLIANCE WITH
 SEC. 607.4.1- 607.4.1.2 UNLESS INSTALLING
 REINFORCEMENTS IN ACCORDANCE WITH EXCEPTION 2.
  
 M) SEC. 607.5: SHOW THE BATHTUB CONTROLS LOCATION.
  
 3) SHEET A-10: PLEASE REFER TO PAGES 7.36 & 7.65 OF THE
 FHDA MANUAL AND REVISE THE DIAGRAM TO SHOW THE CLEAR
 FLOOR SPACE DIAGRAMS AND DIMENSIONS INSIDE THE BATH
 FLOOR PLAN DRAWING- SEC. 107.2.1 WPB. PLEASE NOTE SHEET
 A-10.1 WHICH MAY INCLUDE THE DETAILS IS SHOWN IN THE
 INDEX BUT WAS NOT UPLOADED WITH THE PLAN SET FOR
 REVIEW.
  
 4) A-10: REFER TO PAGES 6.3- 6.9 AND SHOW GRAB BAR
 REINFORCEMENT LOCATIONS WITH DIMENSIONS AT THE TOILET
 AND BATHTUB. PLEASE NOTE SHEET A-10.1 WHICH MAY INCLUDE
 THE DETAILS IS SHOWN IN THE INDEX BUT WAS NOT UPLOADED
 WITH THE PLAN SET FOR REVIEW.
  
 5) P-6: THE PLANS DO NOT SHOW THE WATER HEATER DRAIN
 PAN LINE RUNS AND DISCHARGE LOCATIONS. PLEASE PROVIDE
 DETAILS IN COMPLIANCE WITH SECS. 504.7.1 & 504.7.2 FBC
 P.
  
 6) P-6: PLEASE PROVIDE AN EQUIPMENT SCHEDULE FOR THE
 WATER HEATERS SHOWING THE MAKES AND MODELS, GALLON
 SIZES, AND EFFICIENCY RATINGS TO MATCH WITH THE DATA
 LISTED ON THE SUBMITTED ENERGY COMPLIANCE FORMS- TABLE
 C404.2 FBC EC. THE WATER HEATERS SPECIFICATIONS CAN BE
 DEFERRED SUBMITTALS IF PREFERRED- SEE SEC. 107.3.4.1
 WPB.
  
 7) P-2: PLEASE PROVIDE A STORM DRAIN ISOMETRIC DRAWING
 SHOWING THE VERTICAL AND HORIZONTAL PIPING RUNS AND
 SIZES FROM THE ROOF DRAINS TO DISCHARGE LOCATIONS- SEC.
 107.3.5.1.3 (7) WPB, AND SECS. 1101.2, 1106.2 & 1106.3
 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2023-06-16 Cont ID  
Sent By rmcphers Date 2023-06-16 Time 10:03 Rev Time 0.00
Received By rmcphers Date 2023-06-16 Time 10:03 Sent To  
Notes
2023-06-16 10:03:40ROOFING SYSTEM TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2023-05-08 Cont ID  
Sent By rmcphers Date 2023-05-08 Time 13:42 Rev Time 0.00
Received By rmcphers Date 2023-05-08 Time 13:42 Sent To  
Notes
2023-05-08 13:42:46SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-12-16 Cont ID  
Sent By rmcphers Date 2022-12-16 Time 10:38 Rev Time 0.00
Received By rmcphers Date 2022-12-16 Time 10:37 Sent To  
Notes
2022-12-16 10:38:21SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-07-10 Cont ID  
Sent By rmcphers Date 2023-07-10 Time 13:24 Rev Time 0.00
Received By rmcphers Date 2023-07-10 Time 13:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-06-16 Cont ID  
Sent By rmcphers Date 2023-06-16 Time 10:17 Rev Time 0.00
Received By rmcphers Date 2023-06-16 Time 10:17 Sent To  
Notes
2023-06-12 15:20:46PLUMBING SIGNATURES PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-05-08 Cont ID  
Sent By rmcphers Date 2023-05-08 Time 13:52 Rev Time 0.00
Received By rmcphers Date 2023-05-08 Time 13:52 Sent To  
Notes
2023-05-08 14:07:06SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE CIVIL DRAWINGS FROM RICHARD REIKENIS P.E. DO NOT
 SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-12-16 Cont ID  
Sent By rmcphers Date 2022-12-16 Time 10:42 Rev Time 0.00
Received By rmcphers Date 2022-12-16 Time 10:41 Sent To  
Notes
2022-12-15 09:57:14MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-16 Cont ID  
Sent By jswaby Date 2023-05-16 Time 17:36 Rev Time 0.00
Received By jlswaby Date 2023-05-16 Time 17:36 Sent To  
Notes
2023-05-16 17:35:21CONDITION OF C.O
  
 SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE,
 IRRIGATION, LANDSCAPE, OTHER. IF APPLICABLE
  
 PREVIOUS NOTES: ZONING PROVISOS:
 1. DURING CONSTRUCTION:
 1.1. THE PROPERTY OWNER AND CONTRACTOR SHALL MAKE
 ARRANGEMENTS FOR PARKING OF CONTRACTOR VEHICLES TO
 MINIMIZE THE IMPACT ON ALL NEIGHBORING PROPERTIES.
 1.2. THE PROPERTY OWNER AND CONTRACTOR SHALL PROTECT
 ALL NEIGHBORING PROPERTY, INCLUDING VEHICLES, FROM
 DAMAGE OR DIRT CAUSED BY THE CONSTRUCTION, AND SHALL
 NOTIFY THE OCCUPANTS OF NEIGHBORING PROPERTIES ABOUT
 ALL STAGES OF CONSTRUCTION THAT MAY AFFECT THE USE OF
 THEIR PROPERTY.
 2. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING
 TREES, A TREE ALTERATION PERMIT SHALL BE OBTAINED FROM
 THE DEVELOPMENT SERVICES DEPARTMENT PLANNING DIVISION.
 3. IF APPLICABLE, THE DEVELOPER, ITS SUCCESSORS AND
 ASSIGNS SHALL BE RESPONSIBLE FOR THE PERMITTING AND
 INSTALLATION OF ANY STREET TREES, TREE GRATES, AND
 RIGHT???OF???WAY LANDSCAPING AND IRRIGATION THAT MAY BE
 APPROVED WITH THIS PETITION. ALL PERMITS SHALL BE
 OBTAINED PRIOR TO COMMENCEMENT OF CONSTRUCTION OF SUCH
 IMPROVEMENTS.
 4. IF APPLICABLE, THE DEVELOPER, ITS SUCCESSORS AND
 ASSIGNS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE
 ROAD RIGHT???OF???WAY LANDSCAPING, TREE GRATES AND
 IRRIGATION ADJACENT TO THE PROPERTY THAT MAY BE
 APPROVED WITH THIS PETITION. A MAINTENANCE AGREEMENT
 WITH THE CITY SHALL BE EXECUTED PRIOR TO THE ISSUANCE
 OF A CERTIFICATE OF OCCUPANCY.
 5. IF APPLICABLE, ANY REQUIRED EASEMENTS (I.E.
 DRAINAGE, UTILITIES, PUBLIC ACCESS, OUTFALL, ETC.)SHALL
 BE PROVIDED VIA PLAT OR SEPARATE LEGAL INSTRUMENT.
 6. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS,ETC.)
 SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM
 EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY.
 7. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
 COMMUNITYPLUS V8.1 PAGE NUMBER: 2 PERMIT NUMBER:
 22100754 ??? NEIGHBORHOOD RENAISSANCE INC OCCUPANCY:
 7.1. THE PROPERTY SHALL BE RE???PLATTED IN ACCORDANCE
 WITH ALL APPLICABLE STATUTES, REGULATIONS, AND THE
 CITY???S POLICIES AND PROCEDURES.
 8. THE NEWLY PROPOSED PARKING STALL AREA ALONG GRANT
 STREET MUST BE LOCATED 20???FEET FROM THE EXISTING
 PEDESTRIAN CROSSWALK BY THE TAMARIND INTERSECTION, PER
 FDOT REGULATIONS. PLEASE SHOW SUCH MINIMUM DISTANCE ON
 THE SITE PLAN.
 9. PROVIDE BUS SHELTER DETAILS AND OBTAIN APPROVAL FROM
 PALM TRAN BY COORDINATING WITH YASH
 NAGAL([email protected]); THE CITY???S ENGINEERING
 SERVICES DEPARTMENT SHALL BE COPIED ON THE
 CORRESPONDENCE.
 ________________________________________
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JERMAINE SWABY
 SENIOR PLANNER
 [email protected]
 561-822-1431
 PERSONAL NOTES:
  

Review Stop Z ZONING
Rev No 1 Status P Date 2023-02-03 Cont ID  
Sent By jroach Date 2023-02-03 Time 08:23 Rev Time 0.00
Received By jroach Date 2023-02-03 Time 08:23 Sent To  
Notes
2023-02-03 08:25:50ZONING PROVISOS:
  
 1. DURING CONSTRUCTION:
  
 1.1. THE PROPERTY OWNER AND CONTRACTOR SHALL MAKE
 ARRANGEMENTS FOR PARKING OF CONTRACTOR VEHICLES TO
 MINIMIZE THE IMPACT ON ALL NEIGHBORING PROPERTIES.
  
 1.2. THE PROPERTY OWNER AND CONTRACTOR SHALL PROTECT
 ALL NEIGHBORING PROPERTY, INCLUDING VEHICLES, FROM
 DAMAGE OR DIRT CAUSED BY THE CONSTRUCTION, AND SHALL
 NOTIFY THE OCCUPANTS OF NEIGHBORING PROPERTIES ABOUT
 ALL STAGES OF CONSTRUCTION THAT MAY AFFECT THE USE OF
 THEIR PROPERTY.
  
 2. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING
 TREES, A TREE ALTERATION PERMIT SHALL BE OBTAINED FROM
 THE DEVELOPMENT SERVICES DEPARTMENT ??? PLANNING
 DIVISION.
  
 3. IF APPLICABLE, THE DEVELOPER, ITS SUCCESSORS AND
 ASSIGNS SHALL BE RESPONSIBLE FOR THE PERMITTING AND
 INSTALLATION OF ANY STREET TREES, TREE GRATES, AND
 RIGHT-OF-WAY LANDSCAPING AND IRRIGATION THAT MAY BE
 APPROVED WITH THIS PETITION. ALL PERMITS SHALL BE
 OBTAINED PRIOR TO COMMENCEMENT OF CONSTRUCTION OF SUCH
 IMPROVEMENTS.
  
 4. IF APPLICABLE, THE DEVELOPER, ITS SUCCESSORS AND
 ASSIGNS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE
 ROAD RIGHT-OF-WAY LANDSCAPING, TREE GRATES AND
 IRRIGATION ADJACENT TO THE PROPERTY THAT MAY BE
 APPROVED WITH THIS PETITION. A MAINTENANCE AGREEMENT
 WITH THE CITY SHALL BE EXECUTED PRIOR TO THE ISSUANCE
 OF A CERTIFICATE OF OCCUPANCY.
  
 5. IF APPLICABLE, ANY REQUIRED EASEMENTS (I.E.
 DRAINAGE, UTILITIES, PUBLIC ACCESS, OUTFALL, ETC.)
 SHALL BE PROVIDED VIA PLAT OR SEPARATE LEGAL
 INSTRUMENT.
  
 6. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS,
 ETC.) SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM
 EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY.
  
 7. PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
 OCCUPANCY:
  
 7.1. THE PROPERTY SHALL BE RE-PLATTED IN ACCORDANCE
 WITH ALL APPLICABLE STATUTES, REGULATIONS, AND THE
 CITY???S POLICIES AND PROCEDURES.
  
 8. THE NEWLY PROPOSED PARKING STALL AREA ALONG GRANT
 STREET MUST BE LOCATED 20-FEET FROM THE EXISTING
 PEDESTRIAN CROSSWALK BY THE TAMARIND INTERSECTION, PER
 FDOT REGULATIONS. PLEASE SHOW SUCH MINIMUM DISTANCE ON
 THE SITE PLAN.
  
 9. PROVIDE BUS SHELTER DETAILS AND OBTAIN APPROVAL
 FROM PALM TRAN BY COORDINATING WITH YASH NAGAL
 ([email protected]); THE CITY???S ENGINEERING SERVICES
 DEPARTMENT SHALL BE COPIED ON THE CORRESPONDENCE.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ??? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved