Plan Review Details - Permit 22100679
| Plan Review Stops For Permit 22100679 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-17 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-17 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2022-11-17 09:18:11 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.PROVIDE THE FL PRODUCT APPROVALS FOR THE PROPOSED | | | WINDOWS. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 2. CORRECT DESIGN CRITERIA ON PLAN PAGE A-1: | | | 2A. BUILDING DEPARTMENT IS THE CITY OF WEST PALM BEACH | | | 2B. WIND DESIGN IS ASCE 7-16 | | | 2C. OCCUPANCY IS R-2, MULTI-FAMILY. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. REMOVE NOTE IN KITCHEN AREA OF RIGHT HAND UNIT: | | | REMOVE AND REPLACE TOILET, SINK, TUB, ETC. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-02-10 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-02-07 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-02-07 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2023-02-10 10:54:38 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE PROVIDE DETAILS ON PROPOSED WINDOW AND DOOR | | | REPLACEMENT. WINDOWS MUST HAVE CLEAR GLASS (NO TINT). | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-02-13 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-21 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-10-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-25 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-25 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-17 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-17 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2022-11-17 08:20:05 | CONTRACTOR SIGNED PLANS. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-10 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2023-02-10 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2023-02-10 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2023-02-10 10:51:44 | 1. PLEASE PROVIDE A SURVEY. | | | | | | 2. PARKING LOT RESTRIPING AND REDESIGN SHALL BE UNDER A | | | SEPARATE PERMIT. STRIPING TO MEET CITY PARKING | | | STANDARDS UNDER SEC. 94-485. PLEASE INCLUDE 1 ADA SPACE | | | ON THE PLAN AS WELL. | | | | | | 3. SITE LANDSCAPING AND IRRIGATION SHALL BE UNDER A | | | SEPARATE PERMIT. | | | | | | 4, PLEASE APPLY FOR TREE ALTERATION PERMIT. | | | | | | 5. PLEASE PROVIDE GLAZING DETAIL FOR NEW WINDOWS AND | | | DOORS (REQUIRED CLEAR GLASS). | | | | | | 6 .PROPOSED RENOVATION TO PROPERTY SHOWS A 3RD UNIT, | | | THE MAXIMUM DENSITY FOR THIS DISTRICT IS 14DU/ACRE. | | | PROPERTY IS LIMITED TO 2 RESIDENTIAL UNITS, PLEASE | | | PROVIDE ORIGINAL BUILDING PERMITS OR DOCUMENTATION | | | WHICH APPROVED THE CONVERSION OF THE 3 COMMERICIAL | | | SPACES INTO 3 RESIDENTIAL UNITS. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822-1426 [email protected] |
|
|
|