Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-02-16 Cont ID  
Sent By dbattles Date 2023-02-16 Time 15:15 Rev Time 0.00
Received By dbattles Date 2023-02-16 Time 15:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-13 Cont ID  
Sent By jgomez Date 2023-01-13 Time 09:51 Rev Time 0.00
Received By jgomez Date 2023-01-13 Time 11:22 Sent To  
Notes
2023-01-13 13:40:38RESIDENTIAL(R3)BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22100617
 8560 EGRET LAKES LN
  
 PROVISO NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR
 PRODUCT APPROVALS DEFERRED SUBMITTAL).
  
 ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED
 INFORMATION BEFORE PERMIT ISSUANCE.
  
 NOTE:
 LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING BUILDING.
 SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION
 ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
  
 (1)PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL).
  
 (2)- ENGINEER OF RECORD TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 (3)DETAIL 1 ON SHEET S01 IS INCOMPLETE. PROVIDE
 COMPLETE FRAMING DETAIL AND SPECIFICATIONS FOR WALL
 INFILL CONSTRUCTION TO ALLOW FOR NEW WINDOW
 INSTALLATION. SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: SPECIFY ALL FRAMING MEMBERS AND FASTENERS.
 SPECIFY WALL CONSTRUCTION ON THE INTERIOR AND EXTERIOR
 SIDES OF THE WALL.
  
 (4)THERE ARE DIFFERENT WINDOW/DOOR STRUCTURAL BUCK
 DETAILS SHOWN ON SHEET S01. PROVIDE STRUCTURAL BUCK
 DETAIL FOR NEW WINDOW SHOWING COMPLIANCE WITH SEC.
 R609.7.2.1 FBC-RESIDENTIAL. SPECIFY STRUCTURAL BUCK
 SIZE AND FASTENING.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE WINDOW/DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
 NOTE: KEEP IN MIND DETAIL 1/S01. ONE SIDE OF STRUCTURAL
 BUCK IS NOT ATTACHED TO MASONRY WALL.
  
 (5)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR WALL
 FLASHING AT ALL EXTERIOR OPENINGS. SEC. R703.4
 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-01-04 Cont ID  
Sent By fgiaquin Date 2023-01-04 Time 20:39 Rev Time 0.00
Received By fgiaquin Date 2023-01-03 Time 21:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-16 Cont ID  
Sent By dbattles Date 2023-02-16 Time 15:15 Rev Time 0.00
Received By dbattles Date 2023-02-01 Time 15:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-13 Cont ID  
Sent By jgomez Date 2023-01-13 Time 13:41 Rev Time 0.00
Received By jgomez Date 2022-12-21 Time 05:38 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-12-27 Cont ID  
Sent By medwards Date 2022-12-27 Time 08:16 Rev Time 0.00
Received By medwards Date 2022-12-27 Time 08:16 Sent To  
Notes
2022-12-27 08:16:55NO MECHANICAL WORK SHOWN IN THE SCOPE OF WORK FOR THIS
 PROJECT. ME

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-12-28 Cont ID  
Sent By rwbrown Date 2022-12-28 Time 11:58 Rev Time 0.00
Received By rwbrown Date 2022-12-28 Time 11:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-02-16 Cont ID  
Sent By dbattles Date 2023-02-16 Time 15:15 Rev Time 0.00
Received By dbattles Date 2023-02-16 Time 15:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-01-13 Cont ID  
Sent By jgomez Date 2023-01-13 Time 13:41 Rev Time 0.00
Received By jgomez Date 2023-01-13 Time 13:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-01-03 Cont ID  
Sent By asangele Date 2023-01-03 Time 12:59 Rev Time 0.00
Received By asangele Date 2023-01-03 Time 13:01 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy