Plan Review Details - Permit 22100595
| Plan Review Stops For Permit 22100595 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-02 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-02 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-02 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2023-03-02 14:53:58 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) YOU WILL NEED TO PROVIDE AN ESTIMATE FOR THE | | | ROOF-TO-WALL CONNECTIONS - FBC R908.8.1ROOF-TO-WALL | | | CONNECTIONS FOR STRUCTURES WITH WOOD ROOF DECKS. | | | EXCEPTIONS: 2.ROOF-TO-WALL CONNECTIONS SHALL NOT BE | | | REQUIRED UNLESS EVALUATION AND INSTALLATION OF | | | CONNECTIONS AT GABLE ENDS OR ALL CORNERS CAN BE | | | COMPLETED FOR 15 PERCENT OF THE COST OF ROOF | | | REPLACEMENT. | | | | | | OR --- PLEASE PROVIDE THE DETAILS FOR THE ROOF TO WALL | | | CONNECTIONS - FBC R908.8 WHEN A ROOF COVERING ON AN | | | EXISTING STRUCTURE WITH A SAWN LUMBER, WOOD PLANK OR | | | WOOD STRUCTURAL PANEL ROOF DECK IS REMOVED AND REPLACED | | | ON A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS | | | REGION AS DEFINED IN THE FLORIDA BUILDING CODE, | | | BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR | | | MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH | | | DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A | | | JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD | | | VALOREM TAXATION OF $300,000 OR MORE: | | | | | | (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS | | | REQUIRED BY SECTION R908.8.1. | | | | | | (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION | | | SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN | | | THE COST OF RE-ROOFING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-13 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2023-02-13 14:09:37 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE DETAILS FOR THE ROOF TO WALL | | | CONNECTIONS - FBC R908.8 WHEN A ROOF COVERING ON AN | | | EXISTING STRUCTURE WITH A SAWN LUMBER, WOOD PLANK OR | | | WOOD STRUCTURAL PANEL ROOF DECK IS REMOVED AND REPLACED | | | ON A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS | | | REGION AS DEFINED IN THE FLORIDA BUILDING CODE, | | | BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR | | | MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH | | | DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A | | | JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD | | | VALOREM TAXATION OF $300,000 OR MORE: | | | | | | (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS | | | REQUIRED BY SECTION R908.8.1. | | | | | | (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION | | | SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN | | | THE COST OF RE-ROOFING. | | | | | | 2) THE PROVIDED ADDITIONAL ROOFING ATTACHMENT FROM | | | "FORENSIC ENGINEERING CONSULTANTS" NEEDS TO BE | | | DIGITALLY SIGNED BY THE ENGINEER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-11-03 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-11-03 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2022-11-03 11:26:21 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT | | | LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 128. GENERAL | | | LIMITATION #7 IS SPECIFICALLY REFERRED TO IN THIS NOA. | | | SUBMIT FASTENER DENSITY CALCULATIONS PREPARED, SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT, OR REGISTERED ROOF | | | CONSULTANT. NOTE: THIS PROJECT IS LOCATED IN AN | | | EXPOSURE CATEGORY C AREA. | | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | | OF PROVIDING POSITIVE DRAINAGE. | | | 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | | WALL CONNECTIONS WILL BE IMPROVED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-02 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-01 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-02 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-11-03 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-11-02 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-02 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
|