Plan Review Details - Permit 22100572
Plan Review Stops For Permit 22100572
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-11-08 Cont ID  
Sent By jgomez Date 2022-11-08 Time 13:03 Rev Time 0.00
Received By jgomez Date 2022-11-08 Time 12:52 Sent To  
Notes
2022-11-08 13:04:03NOTE;
 LESS THAN 4:12 ROOF PITCH REQUIRES TWO LAYERS OF
 UNDERLAYMENT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-11-07 Cont ID  
Sent By jgomez Date 2022-11-07 Time 16:41 Rev Time 0.00
Received By jgomez Date 2022-11-07 Time 16:11 Sent To  
Notes
2022-11-07 16:56:47RESIDENTIAL (R 3) ROOFING SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 REVISION #22100572
 530 36TH ST
  
 1- OK
  
 ORIGINAL COMMENT:
 2- DESIGNER OF RECORD TO PROVIDE SPECIFICATIONS SHOWING
 HOW COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR
 ROOFING UNDERLAYMENT. SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE
 PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001.
  
 RESPONSE:
 PARTIALLY COMPLIED. NEED THE FOLLOWING:
  
 A)PROVIDE PRODUCT APPROVAL FOR 4" WIDE STRIPS TO BE
 USED AS REQUESTED ON THE ORIGINAL COMMENT.
 FAC 61G20.3.001.
  
 B) THERE ARE TWO DIFFERENT APOC TUFF FELT UNDERLAYMENTS
 ON NOA 18-0409.06. ARCHITECT TO SPECIFY WHICH ONE IS
 GOING TO BE INSTALLED. REVISE AS REQUIRED.
 NOTE: TABLE R905.1.1.1 FBC-RESIDENTIAL REQUIRES TYPE II
 UNDERLAYMENT.
  
 C) ARCHITECT SPECIFIES ASTM D266 UNDERLAYMENT. IT LOOKS
 LIKE THIS IS A TYPO. THE CORRECT REFERENCE IS ASTM
 D226. CLARIFY/REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 3- MASTER PERMIT WAS APPROVED WITH GAF SHINGLES
 UNDERLAYMENT VERSASHIELD NOA 21-1027.02 (NOTE: SECTION
 R905.1.1.1(4) REQUIRES TWO LAYERS OF THIS
 UNDERLAYMENT).
 IF THERE IS GOING TO BE A DIFFERENT UNDERLAYMENT, THEN
 PROVIDE PRODUCT APPROVAL. NOTE: COORDINATE WITH ITEM #1
 AND #2 ABOVE TO AVOID CONFLICTS/DELAYS.
  
 RESPONSE:
 NOTE: DOUBLE UNDERLAYMENT WILL BE REQUIRED IF THE ROOF
 PITCH IS LESS THAN 4:12. SEE TABLE R905.1.1.1
 FBC-RESIDENTIAL. ARCHITECT TO SPECIFY ROOF PITCH.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-02 Cont ID  
Sent By jgomez Date 2022-11-02 Time 19:42 Rev Time 0.00
Received By jgomez Date 2022-11-02 Time 19:42 Sent To  
Notes
2022-11-02 19:43:25RESIDENTIAL (R 3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 REVISION #22100572
 530 36TH ST
  
 1- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND
 APPROVED (NOT SIGNING AND SEALING) BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL TO THIS OFFICE.
 SEC. 107.3.4.1 CITY AMENDMENTS.
  
 2- DESIGNER OF RECORD TO PROVIDE SPECIFICATIONS SHOWING
 HOW COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR
 ROOFING UNDERLAYMENT. SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE
 PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001.
  
 3- MASTER PERMIT WAS APPROVED WITH GAF SHINGLES
 UNDERLAYMENT VERSASHIELD NOA 21-1027.02 (NOTE: SECTION
 R905.1.1.1(4) REQUIRES TWO LAYERS OF THIS
 UNDERLAYMENT).
 IF THERE IS GOING TO BE A DIFFERENT UNDERLAYMENT, THEN
 PROVIDE PRODUCT APPROVAL. NOTE: COORDINATE WITH ITEM #1
 AND #2 ABOVE TO AVOID CONFLICTS/DELAYS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-11-17 Cont ID  
Sent By amhamilt Date 2022-11-17 Time 12:56 Rev Time 0.00
Received By amhamilt Date 2022-11-17 Time 12:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-18 Cont ID  
Sent By lmarchan Date 2022-11-18 Time 13:03 Rev Time 0.00
Received By lmarchan Date 2022-11-02 Time 11:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-08 Cont ID  
Sent By jgomez Date 2022-11-08 Time 13:07 Rev Time 0.00
Received By jgomez Date 2022-11-08 Time 13:07 Sent To  
Notes
***NONE***