Plan Review Details - Permit 22100511
Plan Review Stops For Permit 22100511
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-11-01 Cont ID  
Sent By jleahy Date 2022-11-01 Time 15:04 Rev Time 0.00
Received By jleahy Date 2022-11-01 Time 13:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-17 Cont ID  
Sent By cwalker Date 2022-10-17 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-10-17 12:30:49FIRE PROVISO COMMENTS:
 7.2.1.6* SPECIAL LOCKING ARRANGEMENTS.
 7.2.1.6.1 DELAYED-EGRESS LOCKING SYSTEMS.
 7.2.1.6.1.1 APPROVED, LISTED, DELAYED-EGRESS LOCKING
 SYSTEMS SHALL BE PERMITTED TO BE INSTALLED ON DOOR
 ASSEMBLIES SERVING
 LOW AND ORDINARY HAZARD CONTENTS IN BUILDINGS PROTECTED
 THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC FIRE
 DETECTION
 SYSTEM IN ACCORDANCE WITH SECTION 9.6 OR AN APPROVED,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH SECTION
 9.7, AND WHERE PERMITTED IN CHAPTERS 11 THROUGH 43,
 PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET:
 (1) THE DOOR LEAVES SHALL UNLOCK IN THE DIRECTION OF
 EGRESS UPON ACTUATION OF ONE OF THE FOLLOWING: (A)
 APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN
 ACCORDANCE WITH SECTION 9.7 (B) NOT MORE THAN ONE HEAT
 DETECTOR OF AN APPROVED, SUPERVISED AUTOMATIC FIRE
 DETECTION SYSTEM IN ACCORDANCE WITH SECTION 9.6 (C) NOT
 MORE THAN TWO SMOKE DETECTORS OF AN APPROVED,
 SUPERVISED AUTOMATIC FIRE DETECTION SYSTEM IN
 ACCORDANCE WITH SECTION 9.6 (2) THE DOOR LEAVES SHALL
 UNLOCK IN THE DIRECTION OF EGRESS UPON LOSS OF POWER
 CONTROLLING THE LOCK OR LOCKING MECHANISM. (3)*AN
 IRREVERSIBLE PROCESS SHALL RELEASE THE LOCK IN THE
 DIRECTION OF EGRESS WITHIN 15 SECONDS, OR 30 SECONDS
 WHERE APPROVED BY THE AUTHORITY HAVING JURISDICTION,
 UPON APPLICATION OF A FORCE TO THE RELEASE DEVICE
 REQUIRED IN 7.2.1.5.10 UNDER ALL OF THE FOLLOWING
 CONDITIONS: (A) THE FORCE SHALL NOT BE REQUIRED TO
 EXCEED 15 LBF (67 N). (B) THE FORCE SHALL NOT BE
 REQUIRED TO BE CONTINUOUSLY APPLIED FOR MORE THAN 3
 SECONDS. (C) THE INITIATION OF THE RELEASE PROCESS
 SHALL ACTIVATE AN AUDIBLE SIGNAL IN THE VICINITY OF THE
 DOOR OPENING.
 (D) ONCE THE LOCK HAS BEEN RELEASED BY THE APPLICATION
 OF FORCE TO THE RELEASING DEVICE, RELOCKING SHALL BE BY
 MANUAL MEANS ONLY. (4)*A READILY VISIBLE, DURABLE SIGN
 IN LETTERS NOT LESS THAN 1 IN. (25 MM) HIGH AND NOT
 LESS THAN 1???8 IN. (3.2 MM) IN STROKE WIDTH ON A
 CONTRASTING BACKGROUND SHALL BE LOCATED ON THE DOOR
 LEAF ADJACENT TO THE RELEASE DEVICE IN THE DIRECTION
 OF EGRESS, AND SHALL READ AS FOLLOWS: (A) PUSH UNTIL
 ALARM SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS, FOR
 DOORS THAT SWING IN THE DIRECTION OF EGRESS TRAVEL (B)
 PULL UNTIL ALARM SOUNDS, DOOR CAN BE OPENED IN 15
 SECONDS, FOR DOORS THAT SWING AGAINST THE DIRECTION OF
 EGRESS TRAVEL (5) THE EGRESS SIDE OF DOORS EQUIPPED
 WITH DELAYED-EGRESS
 LOCKS SHALL BE PROVIDED WITH EMERGENCY LIGHTING IN
 ACCORDANCE WITH SECTION 7.9.
 7.2.1.6.2* ACCESS-CONTROLLED EGRESS DOOR ASSEMBLIES.
 WHERE PERMITTED IN CHAPTERS 11 THROUGH 43, DOOR
 ASSEMBLIES IN THE MEANS OF EGRESS SHALL BE PERMITTED TO
 BE EQUIPPED WITH ELECTRICAL LOCK HARDWARE THAT PREVENTS
 EGRESS, PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE
 MET: (1) A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE,
 ARRANGED TO UNLOCK THE DOOR LEAF IN THE DIRECTION OF
 EGRESS UPON DETECTION OF AN APPROACHING OCCUPANT. (2)
 DOOR LEAVES SHALL AUTOMATICALLY UNLOCK IN THE DIRECTION
 OF EGRESS UPON LOSS OF POWER TO THE SENSOR OR TO THE
 PART OF THE ACCESS CONTROL SYSTEM THAT LOCKS THE DOOR
 LEAVES.
 (3) DOOR LOCKS SHALL BE ARRANGED TO UNLOCK IN THE
 DIRECTION OF EGRESS FROM A MANUAL RELEASE DEVICE
 COMPLYING WITH ALL OF
 THE FOLLOWING CRITERIA: (A) THE MANUAL RELEASE DEVICE
 SHALL BE LOCATED ON THE EGRESS SIDE, 40 IN. TO 48 IN.
 (1015 MM TO 1220 MM) VERTICALLY ABOVE THE FLOOR, AND
 WITHIN 60 IN. (1525 MM) OF THE SECURED DOOR OPENINGS.
 (B) THE MANUAL RELEASE DEVICE SHALL BE READILY
 ACCESSIBLE AND CLEARLY IDENTIFIED BY A SIGN THAT READS
 AS FOLLOWS: PUSH TO EXIT. (C) WHEN OPERATED, THE MANUAL
 RELEASE DEVICE SHALL RESULT IN DIRECT INTERRUPTION OF
 POWER TO THE LOCK ??? INDEPENDENT OF THE LOCKING SYSTEM
 ELECTRONICS???AND THE LOCK SHALL REMAIN UNLOCKED FOR
 NOT LESS THAN 30 SECONDS. (4) ACTIVATION OF THE
 BUILDING FIRE-PROTECTIVE SIGNALING SYSTEM, IF PROVIDED,
 SHALL AUTOMATICALLY UNLOCK THE DOOR LEAVES IN THE
 DIRECTION OF EGRESS, AND THE DOOR LEAVES SHALL REMAIN
 UNLOCKED UNTIL THE FIRE-PROTECTIVE SIGNALING SYSTEM HAS
 BEEN MANUALLY RESET. (5) THE ACTIVATION OF MANUAL FIRE
 ALARM BOXES THAT ACTIVATE THE BUILDING FIRE-PROTECTIVE
 SIGNALING SYSTEM SPECIFIED IN 7.2.1.6.2(4) SHALL NOT BE
 REQUIRED TO UNLOCK THE DOOR LEAVES. (6) ACTIVATION OF
 THE BUILDING AUTOMATIC SPRINKLER OR FIRE DETECTION
 SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY UNLOCK THE
 DOOR LEAVES IN THE DIRECTION OF EGRESS, AND THE DOOR
 LEAVES SHALL REMAIN UNLOCKED UNTIL THE FIRE-PROTECTIVE
 SIGNALING SYSTEM HAS BEEN MANUALLY RESET. (7) THE
 EGRESS SIDE OF ACCESS-CONTROLLED EGRESS DOORS, OTHER
 THAN
 EXISTING ACCESS-CONTROLLED EGRESS DOORS, SHALL BE
 PROVIDED WITH EMERGENCY LIGHTING IN ACCORDANCE WITH
 SECTION 7.9.
  
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-01 Cont ID  
Sent By mpeterso Date 2022-11-01 Time 14:25 Rev Time 0.00
Received By mpeterso Date 2022-10-13 Time 06:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-11-01 Cont ID  
Sent By mpeterso Date 2022-11-01 Time 14:25 Rev Time 0.00
Received By mpeterso Date 2022-11-01 Time 14:25 Sent To  
Notes
***NONE***