Plan Review Details - Permit 22100502
Plan Review Stops For Permit 22100502
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-16 Cont ID  
Sent By shill Date 2022-11-16 Time 19:45 Rev Time 0.00
Received By shill Date 2022-11-16 Time 19:44 Sent To  
Notes
2022-11-16 19:45:35****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 107 SCOPE NOT CLEAR. SHEET 1 STATES THAT THIS IS
 "FACE LIGHTED CHANNEL LOGO/LETTERS" BUT STRUCTURAL
 PLANS FOR CHANNEL LETTERS WERE NOT SUBMITTED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-11-01 Cont ID  
Sent By fgiaquin Date 2022-11-01 Time 20:56 Rev Time 0.00
Received By fgiaquin Date 2022-11-01 Time 19:17 Sent To  
Notes
2022-11-01 20:56:33ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY
 THE ELECTRICAL CONTRACTOR QUALIFIER. NO WIRING DIAGRAM
 HAS BEEN PROVIDED FOR SIGN. FS 471.003(2)(H); 471.025;
 WPB FBC 107.2.1, 107.3.5
  
 2. PROVIDE DISCONNECT REQUIRED PER NEC 600.6A1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-02 Cont ID  
Sent By lmarchan Date 2022-12-02 Time 16:57 Rev Time 0.00
Received By lmarchan Date 2022-10-13 Time 06:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-16 Cont ID  
Sent By shill Date 2022-11-16 Time 19:45 Rev Time 0.00
Received By shill Date 2022-11-16 Time 19:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-12-02 Cont ID  
Sent By llouie Date 2022-12-02 Time   Rev Time  
Received By llouie Date 2022-12-02 Time   Sent To  
Notes
2022-12-02 16:38:05** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) NO BUILDING FACADE DIMENSIONS PROVIDED. BUILDING
 FACADE DIMENSIONS REQUIRED TO DETERMINE MAXIMUM
 ALLOWABLE SIGN AREA AND IF THE PROPOSED SIGN AREA IS IN
 COMPLIANCE.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: CSPD (ST. MARY'S CSPD)
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved